CVE-2020-8327 (GCVE-0-2020-8327)
Vulnerability from cvelistv5
Published
2020-04-14 21:05
Modified
2024-09-17 00:11
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-428 - Unquoted Search Path or Element
Summary
A privilege escalation vulnerability was reported in LenovoBatteryGaugePackage for Lenovo System Interface Foundation bundled in Lenovo Vantage prior to version 10.2003.10.0 that could allow an authenticated user to execute code with elevated privileges.
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:56:28.313Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Vantage",
"vendor": "Lenovo",
"versions": [
{
"lessThan": "10.2003.10.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Jonas Lykkeg\u00e5rd for reporting this issue."
}
],
"datePublic": "2020-04-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A privilege escalation vulnerability was reported in LenovoBatteryGaugePackage for Lenovo System Interface Foundation bundled in Lenovo Vantage prior to version 10.2003.10.0 that could allow an authenticated user to execute code with elevated privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428 Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-14T21:05:21.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
],
"solutions": [
{
"lang": "en",
"value": "To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"DATE_PUBLIC": "2020-04-14T21:00:00.000Z",
"ID": "CVE-2020-8327",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Vantage",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "10.2003.10.0"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Jonas Lykkeg\u00e5rd for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A privilege escalation vulnerability was reported in LenovoBatteryGaugePackage for Lenovo System Interface Foundation bundled in Lenovo Vantage prior to version 10.2003.10.0 that could allow an authenticated user to execute code with elevated privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-428 Unquoted Search Path or Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-30401",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
}
]
},
"solution": [
{
"lang": "en",
"value": "To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
}
],
"source": {
"advisory": "LEN-30401",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2020-8327",
"datePublished": "2020-04-14T21:05:21.274Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:11:17.525Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…