Summary
A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:49:06.995Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-26080",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-13T17:22:13.624381Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-13T17:39:03.072Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco IoT Field Network Director (IoT-FND)",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-11-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-11-18T17:40:46.000Z",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78"
        }
      ],
      "source": {
        "advisory": "cisco-sa-FND-UPWD-dCRPuQ78",
        "defect": [
          [
            "CSCvt45294"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2020-11-18T16:00:00",
          "ID": "CVE-2020-26080",
          "STATE": "PUBLIC",
          "TITLE": "Cisco IoT Field Network Director Improper Domain Access Control Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco IoT Field Network Director (IoT-FND)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "4.1",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-FND-UPWD-dCRPuQ78",
          "defect": [
            [
              "CSCvt45294"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2020-26080",
    "datePublished": "2020-11-18T17:40:46.724Z",
    "dateReserved": "2020-09-24T00:00:00.000Z",
    "dateUpdated": "2024-11-13T17:39:03.072Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T15:49:06.995Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2020-26080\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-13T17:22:13.624381Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-13T17:25:57.512Z\"}}], \"cna\": {\"title\": \"Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"source\": {\"defect\": [[\"CSCvt45294\"]], \"advisory\": \"cisco-sa-FND-UPWD-dCRPuQ78\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"cvssV3_0\": {\"scope\": \"CHANGED\", \"version\": \"3.0\", \"baseScore\": 4.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"NONE\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco IoT Field Network Director (IoT-FND)\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"datePublic\": \"2020-11-18T00:00:00.000Z\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2020-11-18T17:40:46.000Z\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"version\": \"3.0\", \"baseScore\": \"4.1\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:N\"}}, \"source\": {\"defect\": [[\"CSCvt45294\"]], \"advisory\": \"cisco-sa-FND-UPWD-dCRPuQ78\", \"discovery\": \"INTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"Cisco IoT Field Network Director (IoT-FND)\"}]}, \"vendor_name\": \"Cisco\"}]}}, \"exploit\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-UPWD-dCRPuQ78\", \"name\": \"20201118 Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"refsource\": \"CISCO\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in the user management functionality of Cisco IoT Field Network Director (FND) could allow an authenticated, remote attacker to manage user information for users in different domains on an affected system. The vulnerability is due to improper domain access control. An attacker could exploit this vulnerability by manipulating JSON payloads to target different domains on an affected system. A successful exploit could allow the attacker to manage user information for users in different domains on an affected system.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-284\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2020-26080\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cisco IoT Field Network Director Improper Domain Access Control Vulnerability\", \"ASSIGNER\": \"psirt@cisco.com\", \"DATE_PUBLIC\": \"2020-11-18T16:00:00\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2020-26080\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-13T17:39:03.072Z\", \"dateReserved\": \"2020-09-24T00:00:00.000Z\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2020-11-18T17:40:46.724Z\", \"assignerShortName\": \"cisco\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…