CVE-2020-2075 (GCVE-0-2020-2075)
Vulnerability from cvelistv5
Published
2020-08-31 17:09
Modified
2024-08-04 06:54
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Summary
Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x – CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Bulkscan LMS111; Bulkscan LMS511; CLV62x – CLV65x; ICR890-3; LMS10x, LMS11x, LMS15x; LMS12x, LMS13x, LMS14x; LMS5xx, LMS53x; MSC800; RFH |
Version: All Versions < V1.04 Version: All Versions < V2.30 Version: All versions with Ethernet interface Version: All ICR890-3 and ICR890-3.5 devices all versions Version: All Versions < V2.0 Version: All Versions < V2.10 Version: All versions Version: All Versions < V4.10 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T06:54:00.593Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Bulkscan LMS111; Bulkscan LMS511; CLV62x \u2013 CLV65x; ICR890-3; LMS10x, LMS11x, LMS15x; LMS12x, LMS13x, LMS14x; LMS5xx, LMS53x; MSC800; RFH",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V1.04"
},
{
"status": "affected",
"version": "All Versions \u003c V2.30"
},
{
"status": "affected",
"version": "All versions with Ethernet interface"
},
{
"status": "affected",
"version": "All ICR890-3 and ICR890-3.5 devices all versions"
},
{
"status": "affected",
"version": "All Versions \u003c V2.0"
},
{
"status": "affected",
"version": "All Versions \u003c V2.10"
},
{
"status": "affected",
"version": "All versions"
},
{
"status": "affected",
"version": "All Versions \u003c V4.10"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x \u2013 CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-08-31T17:09:07",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@sick.de",
"ID": "CVE-2020-2075",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Bulkscan LMS111; Bulkscan LMS511; CLV62x \u2013 CLV65x; ICR890-3; LMS10x, LMS11x, LMS15x; LMS12x, LMS13x, LMS14x; LMS5xx, LMS53x; MSC800; RFH",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c V1.04"
},
{
"version_value": "All Versions \u003c V2.30"
},
{
"version_value": "All versions with Ethernet interface"
},
{
"version_value": "All ICR890-3 and ICR890-3.5 devices all versions"
},
{
"version_value": "All Versions \u003c V2.0"
},
{
"version_value": "All Versions \u003c V2.10"
},
{
"version_value": "All versions"
},
{
"version_value": "All Versions \u003c V4.10"
},
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x \u2013 CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-703: Improper Check or Handling of Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories",
"refsource": "MISC",
"url": "https://www.sick.com/de/en/service-and-support/the-sick-product-security-incident-response-team-sick-psirt/w/psirt/#advisories"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2020-2075",
"datePublished": "2020-08-31T17:09:07",
"dateReserved": "2019-12-04T00:00:00",
"dateUpdated": "2024-08-04T06:54:00.593Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…