CVE-2020-14523 (GCVE-0-2020-14523)
Vulnerability from cvelistv5
Published
2022-02-11 17:40
Modified
2025-04-16 18:01
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | CW Configurator |
Version: unspecified < |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T12:46:34.640Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU90224831/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-14523",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:31:26.782063Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T18:01:22.616Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "CW Configurator",
"vendor": "Mitsubishi Electric",
"versions": [
{
"lessThanOrEqual": "Version 1.010L",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "FR Configurator2",
"vendor": "Mitsubishi Electric",
"versions": [
{
"lessThanOrEqual": "Version 1.22Y",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "GX Works2",
"vendor": "Mitsubishi Electric",
"versions": [
{
"lessThanOrEqual": "Version 1.595V",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "GX Works3",
"vendor": "Mitsubishi Electric",
"versions": [
{
"lessThanOrEqual": "Version 1.063R",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "MELSOFT iQ AppPortal",
"vendor": "Mitsubishi Electric",
"versions": [
{
"lessThanOrEqual": "Version 1.17T",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "MELSOFT Navigator",
"vendor": "Mitsubishi Electric",
"versions": [
{
"lessThanOrEqual": "Version2.70Y",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "MI Configurator",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"product": "MR Configurator2",
"vendor": "Mitsubishi Electric",
"versions": [
{
"lessThanOrEqual": "Version 1.110Q",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "MT Works2",
"vendor": "Mitsubishi Electric",
"versions": [
{
"lessThanOrEqual": "Versions 1.156N",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "MX Component",
"vendor": "Mitsubishi Electric",
"versions": [
{
"lessThanOrEqual": "Version 4.20W",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "RT ToolBox3",
"vendor": "Mitsubishi Electric",
"versions": [
{
"lessThanOrEqual": "Versions 1.70Y",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "MELSEC iQ-R Series Motion Module",
"vendor": "Mitsubishi Electric",
"versions": [
{
"lessThanOrEqual": "Versions 10",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
}
],
"datePublic": "2020-07-30T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-18T23:17:23.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU90224831/"
}
],
"source": {
"advisory": "ICSA-20-212-03",
"discovery": "UNKNOWN"
},
"title": "Mitsubishi Electric Factory Automation Products Path Traversal",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-07-30T16:50:00.000Z",
"ID": "CVE-2020-14523",
"STATE": "PUBLIC",
"TITLE": "Mitsubishi Electric Factory Automation Products Path Traversal"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CW Configurator",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 1.010L"
}
]
}
},
{
"product_name": "FR Configurator2",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 1.22Y"
}
]
}
},
{
"product_name": "GX Works2",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 1.595V"
}
]
}
},
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 1.063R"
}
]
}
},
{
"product_name": "MELSOFT iQ AppPortal",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 1.17T"
}
]
}
},
{
"product_name": "MELSOFT Navigator",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version2.70Y"
}
]
}
},
{
"product_name": "MI Configurator",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
},
{
"product_name": "MR Configurator2",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 1.110Q"
}
]
}
},
{
"product_name": "MT Works2",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Versions 1.156N"
}
]
}
},
{
"product_name": "MX Component",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Version 4.20W"
}
]
}
},
{
"product_name": "RT ToolBox3",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Versions 1.70Y"
}
]
}
},
{
"product_name": "MELSEC iQ-R Series Motion Module",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "Versions 10"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
},
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU90224831/",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU90224831/"
}
]
},
"solution": [
{
"lang": "en"
}
],
"source": {
"advisory": "ICSA-20-212-03",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-14523",
"datePublished": "2022-02-11T17:40:29.187Z",
"dateReserved": "2020-06-19T00:00:00.000Z",
"dateUpdated": "2025-04-16T18:01:22.616Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU90224831/\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T12:46:34.640Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2020-14523\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-16T17:31:26.782063Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-16T17:31:28.177Z\"}}], \"cna\": {\"title\": \"Mitsubishi Electric Factory Automation Products Path Traversal\", \"source\": {\"advisory\": \"ICSA-20-212-03\", \"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"value\": \"Mashav Sapir of Claroty reported this vulnerability to CISA\"}], \"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Mitsubishi Electric\", \"product\": \"CW Configurator\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Version 1.010L\"}]}, {\"vendor\": \"Mitsubishi Electric\", \"product\": \"FR Configurator2\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Version 1.22Y\"}]}, {\"vendor\": \"Mitsubishi Electric\", \"product\": \"GX Works2\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Version 1.595V\"}]}, {\"vendor\": \"Mitsubishi Electric\", \"product\": \"GX Works3\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Version 1.063R\"}]}, {\"vendor\": \"Mitsubishi Electric\", \"product\": \"MELSOFT iQ AppPortal\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Version 1.17T\"}]}, {\"vendor\": \"Mitsubishi Electric\", \"product\": \"MELSOFT Navigator\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Version2.70Y\"}]}, {\"vendor\": \"Mitsubishi Electric\", \"product\": \"MI Configurator\", \"versions\": [{\"status\": \"affected\", \"version\": \"All Versions\"}]}, {\"vendor\": \"Mitsubishi Electric\", \"product\": \"MR Configurator2\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Version 1.110Q\"}]}, {\"vendor\": \"Mitsubishi Electric\", \"product\": \"MT Works2\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Versions 1.156N\"}]}, {\"vendor\": \"Mitsubishi Electric\", \"product\": \"MX Component\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Version 4.20W\"}]}, {\"vendor\": \"Mitsubishi Electric\", \"product\": \"RT ToolBox3\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Versions 1.70Y\"}]}, {\"vendor\": \"Mitsubishi Electric\", \"product\": \"MELSEC iQ-R Series Motion Module\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Versions 10\"}]}], \"datePublic\": \"2020-07-30T00:00:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU90224831/\", \"tags\": [\"x_refsource_MISC\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-22\", \"description\": \"CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2022-02-18T23:17:23.000Z\"}, \"x_legacyV4Record\": {\"credit\": [{\"lang\": \"eng\", \"value\": \"Mashav Sapir of Claroty reported this vulnerability to CISA\"}], \"impact\": {\"cvss\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, \"source\": {\"advisory\": \"ICSA-20-212-03\", \"discovery\": \"UNKNOWN\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"Version 1.010L\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"CW Configurator\"}, {\"version\": {\"version_data\": [{\"version_value\": \"Version 1.22Y\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"FR Configurator2\"}, {\"version\": {\"version_data\": [{\"version_value\": \"Version 1.595V\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"GX Works2\"}, {\"version\": {\"version_data\": [{\"version_value\": \"Version 1.063R\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"GX Works3\"}, {\"version\": {\"version_data\": [{\"version_value\": \"Version 1.17T\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"MELSOFT iQ AppPortal\"}, {\"version\": {\"version_data\": [{\"version_value\": \"Version2.70Y\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"MELSOFT Navigator\"}, {\"version\": {\"version_data\": [{\"version_value\": \"All Versions\", \"version_affected\": \"=\"}]}, \"product_name\": \"MI Configurator\"}, {\"version\": {\"version_data\": [{\"version_value\": \"Version 1.110Q\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"MR Configurator2\"}, {\"version\": {\"version_data\": [{\"version_value\": \"Versions 1.156N\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"MT Works2\"}, {\"version\": {\"version_data\": [{\"version_value\": \"Version 4.20W\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"MX Component\"}, {\"version\": {\"version_data\": [{\"version_value\": \"Versions 1.70Y\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"RT ToolBox3\"}, {\"version\": {\"version_data\": [{\"version_value\": \"Versions 10\", \"version_affected\": \"\u003c=\"}]}, \"product_name\": \"MELSEC iQ-R Series Motion Module\"}]}, \"vendor_name\": \"Mitsubishi Electric\"}]}}, \"solution\": [{\"lang\": \"en\"}], \"data_type\": \"CVE\", \"generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"references\": {\"reference_data\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03\", \"name\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03\", \"refsource\": \"MISC\"}, {\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf\", \"name\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf\", \"refsource\": \"MISC\"}, {\"url\": \"https://jvn.jp/vu/JVNVU90224831/\", \"name\": \"https://jvn.jp/vu/JVNVU90224831/\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2020-14523\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Mitsubishi Electric Factory Automation Products Path Traversal\", \"ASSIGNER\": \"ics-cert@hq.dhs.gov\", \"DATE_PUBLIC\": \"2020-07-30T16:50:00.000Z\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2020-14523\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-16T18:01:22.616Z\", \"dateReserved\": \"2020-06-19T00:00:00.000Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2022-02-11T17:40:29.187Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…