CVE-2019-6528 (GCVE-0-2019-6528)
Vulnerability from cvelistv5
Published
2019-03-05 21:00
Modified
2024-09-16 23:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION ('CROSS-SITE SCRIPTING')
Summary
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| ICS-CERT | PSI GridConnect GmbH (formerly known as PSI Nentec GmbH) Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy. |
Version: Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior. |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:21.722Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "107201",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/107201"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-059-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PSI GridConnect GmbH (formerly known as PSI Nentec GmbH) Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy.",
"vendor": "ICS-CERT",
"versions": [
{
"status": "affected",
"version": "Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior."
}
]
}
],
"datePublic": "2019-03-05T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (\u0027CROSS-SITE SCRIPTING\u0027) CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-06T10:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "107201",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/107201"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-059-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2019-03-05T00:00:00",
"ID": "CVE-2019-6528",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PSI GridConnect GmbH (formerly known as PSI Nentec GmbH) Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy.",
"version": {
"version_data": [
{
"version_value": "Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior."
}
]
}
}
]
},
"vendor_name": "ICS-CERT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (\u0027CROSS-SITE SCRIPTING\u0027) CWE-79"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "107201",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/107201"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-059-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-059-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-6528",
"datePublished": "2019-03-05T21:00:00.000Z",
"dateReserved": "2019-01-22T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:10:35.249Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…