CVE-2019-3929 (GCVE-0-2019-3929)
Vulnerability from cvelistv5
Published
2019-04-30 20:21
Modified
2025-10-21 23:45
Severity ?
CWE
  • CWE-79 - OS Command Injection
Summary
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Impacted products
Vendor Product Version
Crestron Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4. Version: Crestron AM-100 firmware 1.6.0.2
Version: Crestron AM-101 firmware 2.7.0.1
Version: Barco wePresent WiPG-1000P firmware 2.3.0.10
Version: Barco wePresent WiPG-1600W before firmware 2.4.1.19
Version: Extron ShareLink 200/250 firmware 2.0.3.4
Version: Teq AV IT WIPS710 firmware 1.1.0.7
Version: SHARP PN-L703WA firmware 1.4.2.3
Version: Optoma WPS-Pro firmware 1.0.0.5
Version: Blackbox HD WPS firmware 1.0.0.5
Version: InFocus LiteShow3 firmware 1.0.16
Version: and InFocus LiteShow4 2.0.0.7
Create a notification for this product.
CISA Known Exploited Vulnerability
Data from the CISA Known Exploited Vulnerabilities Catalog

Date added: 2022-04-15

Due date: 2022-05-06

Required action: Apply updates per vendor instructions.

Used in ransomware: Unknown

Notes: https://nvd.nist.gov/vuln/detail/CVE-2019-3929

Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:26:27.549Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2019-20"
          },
          {
            "name": "46786",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/46786/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2019-3929",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-06T20:26:27.910638Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2022-04-15",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
              },
              "type": "kev"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T23:45:38.287Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2022-04-15T00:00:00.000Z",
            "value": "CVE-2019-3929 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
          "vendor": "Crestron",
          "versions": [
            {
              "status": "affected",
              "version": "Crestron AM-100 firmware 1.6.0.2"
            },
            {
              "status": "affected",
              "version": "Crestron AM-101 firmware 2.7.0.1"
            },
            {
              "status": "affected",
              "version": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
            },
            {
              "status": "affected",
              "version": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
            },
            {
              "status": "affected",
              "version": "Extron ShareLink 200/250 firmware 2.0.3.4"
            },
            {
              "status": "affected",
              "version": "Teq AV IT WIPS710 firmware 1.1.0.7"
            },
            {
              "status": "affected",
              "version": "SHARP PN-L703WA firmware 1.4.2.3"
            },
            {
              "status": "affected",
              "version": "Optoma WPS-Pro firmware 1.0.0.5"
            },
            {
              "status": "affected",
              "version": "Blackbox HD WPS firmware 1.0.0.5"
            },
            {
              "status": "affected",
              "version": "InFocus LiteShow3 firmware 1.0.16"
            },
            {
              "status": "affected",
              "version": "and InFocus LiteShow4 2.0.0.7"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-14T17:06:03.000Z",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2019-20"
        },
        {
          "name": "46786",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/46786/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnreport@tenable.com",
          "ID": "CVE-2019-3929",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Crestron AM-100 firmware 1.6.0.2"
                          },
                          {
                            "version_value": "Crestron AM-101 firmware 2.7.0.1"
                          },
                          {
                            "version_value": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
                          },
                          {
                            "version_value": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
                          },
                          {
                            "version_value": "Extron ShareLink 200/250 firmware 2.0.3.4"
                          },
                          {
                            "version_value": "Teq AV IT WIPS710 firmware 1.1.0.7"
                          },
                          {
                            "version_value": "SHARP PN-L703WA firmware 1.4.2.3"
                          },
                          {
                            "version_value": "Optoma WPS-Pro firmware 1.0.0.5"
                          },
                          {
                            "version_value": "Blackbox HD WPS firmware 1.0.0.5"
                          },
                          {
                            "version_value": "InFocus LiteShow3 firmware 1.0.16"
                          },
                          {
                            "version_value": "and InFocus LiteShow4 2.0.0.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Crestron"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 OS Command Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2019-20",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2019-20"
            },
            {
              "name": "46786",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/46786/"
            },
            {
              "name": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
            },
            {
              "name": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2019-3929",
    "datePublished": "2019-04-30T20:21:09.000Z",
    "dateReserved": "2019-01-03T00:00:00.000Z",
    "dateUpdated": "2025-10-21T23:45:38.287Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "cisa_known_exploited": {
      "cveID": "CVE-2019-3929",
      "cwes": "[\"CWE-79\"]",
      "dateAdded": "2022-04-15",
      "dueDate": "2022-05-06",
      "knownRansomwareCampaignUse": "Unknown",
      "notes": "https://nvd.nist.gov/vuln/detail/CVE-2019-3929",
      "product": "Multiple Products",
      "requiredAction": "Apply updates per vendor instructions.",
      "shortDescription": "Multiple Crestron products are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.",
      "vendorProject": "Crestron",
      "vulnerabilityName": "Crestron Multiple Products Command Injection Vulnerability"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.tenable.com/security/research/tra-2019-20\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"https://www.exploit-db.com/exploits/46786/\", \"name\": \"46786\", \"tags\": [\"exploit\", \"x_refsource_EXPLOIT-DB\", \"x_transferred\"]}, {\"url\": \"http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T19:26:27.549Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2019-3929\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"active\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-06T20:26:27.910638Z\"}}}, {\"other\": {\"type\": \"kev\", \"content\": {\"dateAdded\": \"2022-04-15\", \"reference\": \"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929\"}}}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2022-04-15T00:00:00.000Z\", \"value\": \"CVE-2019-3929 added to CISA KEV\"}], \"references\": [{\"url\": \"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929\", \"tags\": [\"government-resource\"]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-06T20:25:53.616Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"Crestron\", \"product\": \"Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.\", \"versions\": [{\"status\": \"affected\", \"version\": \"Crestron AM-100 firmware 1.6.0.2\"}, {\"status\": \"affected\", \"version\": \"Crestron AM-101 firmware 2.7.0.1\"}, {\"status\": \"affected\", \"version\": \"Barco wePresent WiPG-1000P firmware 2.3.0.10\"}, {\"status\": \"affected\", \"version\": \"Barco wePresent WiPG-1600W before firmware 2.4.1.19\"}, {\"status\": \"affected\", \"version\": \"Extron ShareLink 200/250 firmware 2.0.3.4\"}, {\"status\": \"affected\", \"version\": \"Teq AV IT WIPS710 firmware 1.1.0.7\"}, {\"status\": \"affected\", \"version\": \"SHARP PN-L703WA firmware 1.4.2.3\"}, {\"status\": \"affected\", \"version\": \"Optoma WPS-Pro firmware 1.0.0.5\"}, {\"status\": \"affected\", \"version\": \"Blackbox HD WPS firmware 1.0.0.5\"}, {\"status\": \"affected\", \"version\": \"InFocus LiteShow3 firmware 1.0.16\"}, {\"status\": \"affected\", \"version\": \"and InFocus LiteShow4 2.0.0.7\"}]}], \"references\": [{\"url\": \"https://www.tenable.com/security/research/tra-2019-20\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"https://www.exploit-db.com/exploits/46786/\", \"name\": \"46786\", \"tags\": [\"exploit\", \"x_refsource_EXPLOIT-DB\"]}, {\"url\": \"http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html\", \"tags\": [\"x_refsource_MISC\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 OS Command Injection\"}]}], \"providerMetadata\": {\"orgId\": \"5ac1ecc2-367a-4d16-a0b2-35d495ddd0be\", \"shortName\": \"tenable\", \"dateUpdated\": \"2020-01-14T17:06:03.000Z\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"Crestron AM-100 firmware 1.6.0.2\"}, {\"version_value\": \"Crestron AM-101 firmware 2.7.0.1\"}, {\"version_value\": \"Barco wePresent WiPG-1000P firmware 2.3.0.10\"}, {\"version_value\": \"Barco wePresent WiPG-1600W before firmware 2.4.1.19\"}, {\"version_value\": \"Extron ShareLink 200/250 firmware 2.0.3.4\"}, {\"version_value\": \"Teq AV IT WIPS710 firmware 1.1.0.7\"}, {\"version_value\": \"SHARP PN-L703WA firmware 1.4.2.3\"}, {\"version_value\": \"Optoma WPS-Pro firmware 1.0.0.5\"}, {\"version_value\": \"Blackbox HD WPS firmware 1.0.0.5\"}, {\"version_value\": \"InFocus LiteShow3 firmware 1.0.16\"}, {\"version_value\": \"and InFocus LiteShow4 2.0.0.7\"}]}, \"product_name\": \"Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.\"}]}, \"vendor_name\": \"Crestron\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://www.tenable.com/security/research/tra-2019-20\", \"name\": \"https://www.tenable.com/security/research/tra-2019-20\", \"refsource\": \"MISC\"}, {\"url\": \"https://www.exploit-db.com/exploits/46786/\", \"name\": \"46786\", \"refsource\": \"EXPLOIT-DB\"}, {\"url\": \"http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html\", \"name\": \"http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html\", \"refsource\": \"MISC\"}, {\"url\": \"http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html\", \"name\": \"http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-79 OS Command Injection\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2019-3929\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"vulnreport@tenable.com\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2019-3929\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-21T23:45:38.287Z\", \"dateReserved\": \"2019-01-03T00:00:00.000Z\", \"assignerOrgId\": \"5ac1ecc2-367a-4d16-a0b2-35d495ddd0be\", \"datePublished\": \"2019-04-30T20:21:09.000Z\", \"assignerShortName\": \"tenable\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…