CVE-2019-11892 (GCVE-0-2019-11892)
Vulnerability from cvelistv5
Published
2019-05-29 19:55
Modified
2024-09-16 17:42
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-284 - Improper Access Control
Summary
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction.
References
| ► | URL | Tags | |||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Bosch | Smart Home Controller |
Version: unspecified < 9.8.905 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:10:29.471Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Smart Home Controller",
"vendor": "Bosch",
"versions": [
{
"lessThan": "9.8.905",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Philip Kazmeier"
}
],
"datePublic": "2019-05-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC\u0027s configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T19:55:13",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2019-05-29T12:00:00.000Z",
"ID": "CVE-2019-11892",
"STATE": "PUBLIC",
"TITLE": "Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Smart Home Controller",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.8.905"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Philip Kazmeier"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC\u0027s configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2019-11892",
"datePublished": "2019-05-29T19:55:13.289812Z",
"dateReserved": "2019-05-13T00:00:00",
"dateUpdated": "2024-09-16T17:42:58.052Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…