CVE-2018-4840 (GCVE-0-2018-4840)
Vulnerability from cvelistv5
Published
2018-03-08 17:00
Modified
2024-08-05 05:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.
References
| ► | URL | Tags | |||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ► | Siemens | DIGSI 4 |
Version: All versions < V4.92 |
||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T05:18:26.487Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DIGSI 4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.92"
}
]
},
{
"product": "EN100 Ethernet module DNP3 variant",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.05.00"
}
]
},
{
"product": "EN100 Ethernet module IEC 104 variant",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "EN100 Ethernet module IEC 61850 variant",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.30"
}
]
},
{
"product": "EN100 Ethernet module Modbus TCP variant",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "EN100 Ethernet module PROFINET IO variant",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"datePublic": "2018-03-08T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in DIGSI 4 (All versions \u003c V4.92), EN100 Ethernet module DNP3 variant (All versions \u003c V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-13T11:02:47",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2018-4840",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DIGSI 4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.92"
}
]
}
},
{
"product_name": "EN100 Ethernet module DNP3 variant",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V1.05.00"
}
]
}
},
{
"product_name": "EN100 Ethernet module IEC 104 variant",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "EN100 Ethernet module IEC 61850 variant",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.30"
}
]
}
},
{
"product_name": "EN100 Ethernet module Modbus TCP variant",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "EN100 Ethernet module PROFINET IO variant",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in DIGSI 4 (All versions \u003c V4.92), EN100 Ethernet module DNP3 variant (All versions \u003c V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-4840",
"datePublished": "2018-03-08T17:00:00",
"dateReserved": "2018-01-02T00:00:00",
"dateUpdated": "2024-08-05T05:18:26.487Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…