CVE-2018-0309 (GCVE-0-2018-0309)
Vulnerability from cvelistv5
Published
2018-06-21 11:00
Modified
2024-11-29 14:58
Severity ?
CWE
Summary
A vulnerability in the implementation of a specific CLI command and the associated Simple Network Management Protocol (SNMP) MIB for Cisco NX-OS (in standalone NX-OS mode) on Cisco Nexus 3000 and 9000 Series Switches could allow an authenticated, remote attacker to exhaust system memory on an affected device, resulting in a denial of service (DoS) condition. The vulnerability is due to the incorrect implementation of the CLI command, resulting in a failure to free all allocated memory upon completion. An attacker could exploit this vulnerability by authenticating to the affected device and repeatedly issuing a specific CLI command or sending a specific SNMP poll request for a specific Object Identifier (OID). A successful exploit could allow the attacker to cause the IP routing process to restart or to cause a device reset, resulting in a DoS condition. Cisco Bug IDs: CSCvf23136.
Impacted products
Vendor Product Version
n/a Cisco Nexus 3000 and 9000 unknown Version: Cisco Nexus 3000 and 9000 unknown
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T03:21:15.219Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-n3k-n9k-clisnmp"
          },
          {
            "name": "1041169",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1041169"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2018-0309",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T14:37:36.811267Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T14:58:01.916Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Nexus 3000 and 9000 unknown",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Cisco Nexus 3000 and 9000 unknown"
            }
          ]
        }
      ],
      "datePublic": "2018-06-21T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the implementation of a specific CLI command and the associated Simple Network Management Protocol (SNMP) MIB for Cisco NX-OS (in standalone NX-OS mode) on Cisco Nexus 3000 and 9000 Series Switches could allow an authenticated, remote attacker to exhaust system memory on an affected device, resulting in a denial of service (DoS) condition. The vulnerability is due to the incorrect implementation of the CLI command, resulting in a failure to free all allocated memory upon completion. An attacker could exploit this vulnerability by authenticating to the affected device and repeatedly issuing a specific CLI command or sending a specific SNMP poll request for a specific Object Identifier (OID). A successful exploit could allow the attacker to cause the IP routing process to restart or to cause a device reset, resulting in a DoS condition. Cisco Bug IDs: CSCvf23136."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-23T09:57:01.000Z",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-n3k-n9k-clisnmp"
        },
        {
          "name": "1041169",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1041169"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "ID": "CVE-2018-0309",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Nexus 3000 and 9000 unknown",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Cisco Nexus 3000 and 9000 unknown"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the implementation of a specific CLI command and the associated Simple Network Management Protocol (SNMP) MIB for Cisco NX-OS (in standalone NX-OS mode) on Cisco Nexus 3000 and 9000 Series Switches could allow an authenticated, remote attacker to exhaust system memory on an affected device, resulting in a denial of service (DoS) condition. The vulnerability is due to the incorrect implementation of the CLI command, resulting in a failure to free all allocated memory upon completion. An attacker could exploit this vulnerability by authenticating to the affected device and repeatedly issuing a specific CLI command or sending a specific SNMP poll request for a specific Object Identifier (OID). A successful exploit could allow the attacker to cause the IP routing process to restart or to cause a device reset, resulting in a DoS condition. Cisco Bug IDs: CSCvf23136."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-n3k-n9k-clisnmp",
              "refsource": "CONFIRM",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-n3k-n9k-clisnmp"
            },
            {
              "name": "1041169",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1041169"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2018-0309",
    "datePublished": "2018-06-21T11:00:00.000Z",
    "dateReserved": "2017-11-27T00:00:00.000Z",
    "dateUpdated": "2024-11-29T14:58:01.916Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…