CVE-2013-10036 (GCVE-0-2013-10036)

Vulnerability from cvelistv5 – Published: 2025-07-31 14:53 – Updated: 2026-07-15 01:23
VLAI
Title
Beetel Connection Manager NetConfig.ini Stack-Based Buffer Overflow
Summary
A stack-based buffer overflow vulnerability exists in Beetel Connection Manager version PCW_BTLINDV1.0.0B04 when parsing the UserName parameter in the NetConfig.ini configuration file. A crafted .ini file containing an overly long UserName value can overwrite the Structured Exception Handler (SEH), leading to arbitrary code execution when the application processes the file.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-31 18:22 UTC
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
VulnCheck CNA
Impacted products
Vendor Product Version
Beetel Teletech Ltd. Connection Manager Affected: PCW_BTLINDV1.0.0B04
    cpe:2.3:a:intel:connection_manager:pcw_btlindv1.0.0b04:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2013-10-15 00:00
Credits
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2013-10036",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-31T18:22:04.170130Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-31T18:22:42.331Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "modules": [
            "NetConfig.ini"
          ],
          "platforms": [
            "Windows"
          ],
          "product": "Connection Manager",
          "vendor": "Beetel Teletech Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "PCW_BTLINDV1.0.0B04"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:intel:connection_manager:pcw_btlindv1.0.0b04:*:*:*:*:*:*:*",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "metacom"
        }
      ],
      "datePublic": "2013-10-15T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A stack-based buffer overflow vulnerability exists in Beetel Connection Manager version \u003ccode\u003ePCW_BTLINDV1.0.0B04\u003c/code\u003e\u0026nbsp;when parsing the \u003ccode\u003eUserName\u003c/code\u003e parameter in the \u003ccode\u003eNetConfig.ini\u003c/code\u003e configuration file. A crafted \u003ccode\u003e.ini\u003c/code\u003e file containing an overly long \u003ccode\u003eUserName\u003c/code\u003e value can overwrite the Structured Exception Handler (SEH), leading to arbitrary code execution when the application processes the file."
            }
          ],
          "value": "A stack-based buffer overflow vulnerability exists in Beetel Connection Manager version PCW_BTLINDV1.0.0B04\u00a0when parsing the UserName parameter in the NetConfig.ini configuration file. A crafted .ini file containing an overly long UserName value can overwrite the Structured Exception Handler (SEH), leading to arbitrary code execution when the application processes the file."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-15T01:23:15.869Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "tags": [
            "exploit"
          ],
          "url": "https://raw.githubusercontent.com/rapid7/metasploit-framework/master/modules/exploits/windows/fileformat/beetel_netconfig_ini_bof.rb"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://www.exploit-db.com/exploits/28969"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.fortiguard.com/encyclopedia/ips/37394/beetel-connection-manager-netconfig-username-buffer-overflow"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.vulncheck.com/advisories/beetel-connection-manager-stack-based-buffer-overflow"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Beetel Connection Manager NetConfig.ini Stack-Based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2013-10036",
    "datePublished": "2025-07-31T14:53:39.747Z",
    "dateReserved": "2025-07-30T16:23:02.149Z",
    "dateUpdated": "2026-07-15T01:23:15.869Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2013-10036",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-31T18:22:04.170130Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-31T18:22:16.405Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "modules": [
                "NetConfig.ini"
              ],
              "platforms": [
                "Windows"
              ],
              "product": "Connection Manager",
              "vendor": "Beetel Teletech Ltd.",
              "versions": [
                {
                  "status": "affected",
                  "version": "PCW_BTLINDV1.0.0B04"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:intel:connection_manager:pcw_btlindv1.0.0b04:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "metacom"
            }
          ],
          "datePublic": "2013-10-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A stack-based buffer overflow vulnerability exists in Beetel Connection Manager version \u003ccode\u003ePCW_BTLINDV1.0.0B04\u003c/code\u003e\u0026nbsp;when parsing the \u003ccode\u003eUserName\u003c/code\u003e parameter in the \u003ccode\u003eNetConfig.ini\u003c/code\u003e configuration file. A crafted \u003ccode\u003e.ini\u003c/code\u003e file containing an overly long \u003ccode\u003eUserName\u003c/code\u003e value can overwrite the Structured Exception Handler (SEH), leading to arbitrary code execution when the application processes the file."
                }
              ],
              "value": "A stack-based buffer overflow vulnerability exists in Beetel Connection Manager version PCW_BTLINDV1.0.0B04\u00a0when parsing the UserName parameter in the NetConfig.ini configuration file. A crafted .ini file containing an overly long UserName value can overwrite the Structured Exception Handler (SEH), leading to arbitrary code execution when the application processes the file."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-15T01:23:15.869Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "tags": [
                "exploit"
              ],
              "url": "https://raw.githubusercontent.com/rapid7/metasploit-framework/master/modules/exploits/windows/fileformat/beetel_netconfig_ini_bof.rb"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/28969"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.fortiguard.com/encyclopedia/ips/37394/beetel-connection-manager-netconfig-username-buffer-overflow"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/beetel-connection-manager-stack-based-buffer-overflow"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Beetel Connection Manager NetConfig.ini Stack-Based Buffer Overflow",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2013-10036",
        "datePublished": "2025-07-31T14:53:39.747Z",
        "dateReserved": "2025-07-30T16:23:02.149Z",
        "dateUpdated": "2026-07-15T01:23:15.869Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.