Search

Find a vulnerability

Search criteria

    112 vulnerabilities by linksys

    CVE-2026-121933 (GCVE-0-2026-121933)

    Vulnerability from cvelistv5 – Published: 2026-11-04 19:15 – Updated: 2026-11-09 16:52
    VLAI
    Title
    Linksys E5350 Setup Wizard apply.cgi save_settings missing authentication
    Summary
    A flaw has been found in Linksys E5350 1.0.00.037. This impacts the function save_settings of the file /wizard/apply.cgi of the component Setup Wizard. Executing a manipulation of the argument wizard_router_pwd can lead to missing authentication. The attack may be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 16:52 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys E5350 Affected: 1.0.00.037
        cpe:2.3:h:linksys:e5350:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-121933",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T16:52:15.532103Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T16:52:34.581Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:linksys:e5350:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Setup Wizard"
              ],
              "product": "E5350",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.00.037"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "liuyingqi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Linksys E5350 1.0.00.037. This impacts the function save_settings of the file /wizard/apply.cgi of the component Setup Wizard. Executing a manipulation of the argument wizard_router_pwd can lead to missing authentication. The attack may be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "Missing Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-04T19:15:17.845Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-431045 | Linksys E5350 Setup Wizard apply.cgi save_settings missing authentication",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/431045"
            },
            {
              "name": "VDB-431045 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/431045/cti"
            },
            {
              "name": "CVE-2026-121933 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-121933"
            },
            {
              "name": "Submit #1024276 | Linksys E5350 1.0.00.037 Improper Authentication (CWE-258 / CWE-306)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1024276"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zimo-666/E5350-cves/tree/main/02-empty-admin-password-auth-bypass"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-04T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-04T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-04T12:45:13.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E5350 Setup Wizard apply.cgi save_settings missing authentication",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-121933",
        "datePublished": "2026-11-04T19:15:17.845Z",
        "dateReserved": "2026-11-04T11:39:36.243Z",
        "dateUpdated": "2026-11-09T16:52:34.581Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-121932 (GCVE-0-2026-121932)

    Vulnerability from cvelistv5 – Published: 2026-11-04 19:00 – Updated: 2026-11-09 16:48
    VLAI
    Title
    Linksys E5350 apply.cgi system os command injection
    Summary
    A vulnerability was detected in Linksys E5350 1.0.00.037. This affects the function system of the file /wizard/apply.cgi. Performing a manipulation of the argument ping_ip/traceroute_ip results in os command injection. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 16:48 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys E5350 Affected: 1.0.00.037
        cpe:2.3:h:linksys:e5350:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-121932",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T16:48:12.254955Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T16:48:31.137Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:linksys:e5350:*:*:*:*:*:*:*:*"
              ],
              "product": "E5350",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.00.037"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "liuyingqi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Linksys E5350 1.0.00.037. This affects the function system of the file /wizard/apply.cgi. Performing a manipulation of the argument ping_ip/traceroute_ip results in os command injection. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-04T19:00:19.173Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-431044 | Linksys E5350 apply.cgi system os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/431044"
            },
            {
              "name": "VDB-431044 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/431044/cti"
            },
            {
              "name": "CVE-2026-121932 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-121932"
            },
            {
              "name": "Submit #1024275 | Linksys E5350 1.0.00.037 Missing Authentication / OS Command Injection (CWE-306 / CWE-78)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1024275"
            },
            {
              "name": "Submit #1024277 | Linksys E5350 1.0.00.037 OS Command Injection (CWE-78) (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1024277"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zimo-666/E5350-cves/tree/main/01-wizard-preauth-command-injection"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-04T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-04T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-04T12:44:55.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E5350 apply.cgi system os command injection",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-121932",
        "datePublished": "2026-11-04T19:00:19.173Z",
        "dateReserved": "2026-11-04T11:39:31.512Z",
        "dateUpdated": "2026-11-09T16:48:31.137Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-121931 (GCVE-0-2026-121931)

    Vulnerability from cvelistv5 – Published: 2026-11-04 18:45 – Updated: 2026-11-09 16:45 Unsupported When Assigned
    VLAI
    Title
    Linksys WRT54GL Traceroute Diagnostic Function apply.cgi system os command injection
    Summary
    A security vulnerability has been detected in Linksys WRT54GL 4.30.18. The impacted element is the function system of the file apply.cgi of the component Traceroute Diagnostic Function. Such manipulation of the argument traceroute_ip leads to os command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 16:45 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys WRT54GL Affected: 4.30.18
        cpe:2.3:h:linksys:wrt54gl:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-121931",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T16:45:17.932298Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T16:45:48.773Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:linksys:wrt54gl:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Traceroute Diagnostic Function"
              ],
              "product": "WRT54GL",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.30.18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "liuyingqi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Linksys WRT54GL 4.30.18. The impacted element is the function system of the file apply.cgi of the component Traceroute Diagnostic Function. Such manipulation of the argument traceroute_ip leads to os command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-04T18:45:14.398Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-431043 | Linksys WRT54GL Traceroute Diagnostic Function apply.cgi system os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/431043"
            },
            {
              "name": "VDB-431043 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/431043/cti"
            },
            {
              "name": "CVE-2026-121931 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-121931"
            },
            {
              "name": "Submit #1024099 | Linksys WRT54GL 4.30.18 OS Command Injection (CWE-78)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1024099"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zimo-666/WRT54GL-cves/tree/main/CVE-TBD-traceroute-ip-command-injection"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-04T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-04T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-04T12:44:51.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys WRT54GL Traceroute Diagnostic Function apply.cgi system os command injection",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-121931",
        "datePublished": "2026-11-04T18:45:14.398Z",
        "dateReserved": "2026-11-04T11:39:26.418Z",
        "dateUpdated": "2026-11-09T16:45:48.773Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-121930 (GCVE-0-2026-121930)

    Vulnerability from cvelistv5 – Published: 2026-11-04 18:30 – Updated: 2026-11-09 16:41 Unsupported When Assigned
    VLAI
    Title
    Linksys WRT54GL Ping Diagnostic apply.cgi system os command injection
    Summary
    A weakness has been identified in Linksys WRT54GL 4.30.18. The affected element is the function system of the file apply.cgi of the component Ping Diagnostic. This manipulation of the argument ping_ip causes os command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 16:41 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys WRT54GL Affected: 4.30.18
        cpe:2.3:h:linksys:wrt54gl:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-121930",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T16:41:16.994593Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T16:41:33.893Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:linksys:wrt54gl:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Ping Diagnostic"
              ],
              "product": "WRT54GL",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.30.18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "liuyingqi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Linksys WRT54GL 4.30.18. The affected element is the function system of the file apply.cgi of the component Ping Diagnostic. This manipulation of the argument ping_ip causes os command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-04T18:30:11.131Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-431042 | Linksys WRT54GL Ping Diagnostic apply.cgi system os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/431042"
            },
            {
              "name": "VDB-431042 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/431042/cti"
            },
            {
              "name": "CVE-2026-121930 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-121930"
            },
            {
              "name": "Submit #1024098 | Linksys WRT54GL 4.30.18 OS Command Injection (CWE-78)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1024098"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zimo-666/WRT54GL-cves/tree/main/CVE-TBD-ping-ip-command-injection"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-04T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-04T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-04T12:44:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys WRT54GL Ping Diagnostic apply.cgi system os command injection",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-121930",
        "datePublished": "2026-11-04T18:30:11.131Z",
        "dateReserved": "2026-11-04T11:39:22.204Z",
        "dateUpdated": "2026-11-09T16:41:33.893Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-121618 (GCVE-0-2026-121618)

    Vulnerability from cvelistv5 – Published: 2026-11-04 03:00 – Updated: 2026-11-09 16:16 Unsupported When Assigned
    VLAI
    Title
    Linksys E5600 Factory Quality Control fqc.cgi information disclosure
    Summary
    A weakness has been identified in Linksys E5600 1.1.0.26. This affects an unknown part of the file /cgi-bin/fqc.cgi of the component Factory Quality Control. This manipulation causes information disclosure. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 16:15 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys E5600 Affected: 1.1.0.26
        cpe:2.3:o:linksys:e5600_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-121618",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T16:15:50.849657Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T16:16:25.423Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:e5600_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Factory Quality Control"
              ],
              "product": "E5600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1.0.26"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "liuyingqi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Linksys E5600 1.1.0.26. This affects an unknown part of the file /cgi-bin/fqc.cgi of the component Factory Quality Control. This manipulation causes information disclosure. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "Information Disclosure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "Improper Access Controls",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-04T03:00:19.621Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-430466 | Linksys E5600 Factory Quality Control fqc.cgi information disclosure",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/vuln/430466"
            },
            {
              "name": "VDB-430466 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/430466/cti"
            },
            {
              "name": "CVE-2026-121618 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-121618"
            },
            {
              "name": "Submit #1023314 | Linksys E5600 1.1.0.26 Information Disclosure (CWE-200)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1023314"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zimo-666/E5600-cves/tree/main/05-fqc-info-disclosure"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-03T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-03T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-03T17:45:21.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E5600 Factory Quality Control fqc.cgi information disclosure",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-121618",
        "datePublished": "2026-11-04T03:00:19.621Z",
        "dateReserved": "2026-11-03T16:40:01.989Z",
        "dateUpdated": "2026-11-09T16:16:25.423Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-121617 (GCVE-0-2026-121617)

    Vulnerability from cvelistv5 – Published: 2026-11-04 02:45 – Updated: 2026-11-09 16:14 Unsupported When Assigned
    VLAI
    Title
    Linksys E5600 Header upload_fw.cgi init_multipart out-of-bounds write
    Summary
    A security flaw has been discovered in Linksys E5600 1.1.0.26. Affected by this issue is the function init_multipart of the file /cgi-bin/upload_fw.cgi of the component Header Parser. The manipulation results in out-of-bounds write. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 16:13 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys E5600 Affected: 1.1.0.26
        cpe:2.3:o:linksys:e5600_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-121617",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T16:13:52.966683Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T16:14:36.779Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:e5600_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Header Parser"
              ],
              "product": "E5600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1.0.26"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "liuyingqi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Linksys E5600 1.1.0.26. Affected by this issue is the function init_multipart of the file /cgi-bin/upload_fw.cgi of the component Header Parser. The manipulation results in out-of-bounds write. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 7.8,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-04T02:45:20.465Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-430465 | Linksys E5600 Header upload_fw.cgi init_multipart out-of-bounds write",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/430465"
            },
            {
              "name": "VDB-430465 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/430465/cti"
            },
            {
              "name": "CVE-2026-121617 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-121617"
            },
            {
              "name": "Submit #1023313 | Linksys E5600 1.1.0.26 Buffer Overflow - Out-of-bounds Write (CWE-787)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1023313"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zimo-666/E5600-cves/tree/main/04-upload-fw-multipart-overflow"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-03T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-03T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-03T17:45:17.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E5600 Header upload_fw.cgi init_multipart out-of-bounds write",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-121617",
        "datePublished": "2026-11-04T02:45:20.465Z",
        "dateReserved": "2026-11-03T16:39:58.548Z",
        "dateUpdated": "2026-11-09T16:14:36.779Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-121616 (GCVE-0-2026-121616)

    Vulnerability from cvelistv5 – Published: 2026-11-04 02:30 – Updated: 2026-11-09 16:13 Unsupported When Assigned
    VLAI
    Title
    Linksys E5600 JSON Request mesh_login.cgi strcpy out-of-bounds write
    Summary
    A vulnerability was identified in Linksys E5600 1.1.0.26. Affected by this vulnerability is the function strcpy of the file /cgi-bin/mesh_login.cgi of the component JSON Request Parser. The manipulation of the argument username/password/token/source/cn/action leads to out-of-bounds write. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 16:12 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys E5600 Affected: 1.1.0.26
        cpe:2.3:o:linksys:e5600_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-121616",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T16:12:20.608218Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T16:13:13.656Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:e5600_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "JSON Request Parser"
              ],
              "product": "E5600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1.0.26"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "liuyingqi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Linksys E5600 1.1.0.26. Affected by this vulnerability is the function strcpy of the file /cgi-bin/mesh_login.cgi of the component JSON Request Parser. The manipulation of the argument username/password/token/source/cn/action leads to out-of-bounds write. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-04T02:30:21.965Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-430464 | Linksys E5600 JSON Request mesh_login.cgi strcpy out-of-bounds write",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/430464"
            },
            {
              "name": "VDB-430464 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/430464/cti"
            },
            {
              "name": "CVE-2026-121616 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-121616"
            },
            {
              "name": "Submit #1023312 | Linksys E5600 1.1.0.26 Buffer Overflow - Out-of-bounds Write (CWE-787)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1023312"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zimo-666/E5600-cves/tree/main/03-mesh-login-global-overflow"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-03T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-03T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-03T17:45:13.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E5600 JSON Request mesh_login.cgi strcpy out-of-bounds write",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-121616",
        "datePublished": "2026-11-04T02:30:21.965Z",
        "dateReserved": "2026-11-03T16:39:55.066Z",
        "dateUpdated": "2026-11-09T16:13:13.656Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-121615 (GCVE-0-2026-121615)

    Vulnerability from cvelistv5 – Published: 2026-11-04 02:15 – Updated: 2026-11-09 16:22 Unsupported When Assigned
    VLAI
    Title
    Linksys E5600 Login mesh_login.cgi improper authentication
    Summary
    A vulnerability was determined in Linksys E5600 1.1.0.26. Affected is an unknown function of the file /cgi-bin/mesh_login.cgi of the component Login Handler. Executing a manipulation can lead to improper authentication. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-09 16:22 UTC
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys E5600 Affected: 1.1.0.26
        cpe:2.3:o:linksys:e5600_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-121615",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-09T16:22:36.999466Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-09T16:22:51.368Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:e5600_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Login Handler"
              ],
              "product": "E5600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1.0.26"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "liuyingqi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Linksys E5600 1.1.0.26. Affected is an unknown function of the file /cgi-bin/mesh_login.cgi of the component Login Handler. Executing a manipulation can lead to improper authentication. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-04T02:15:20.055Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-430463 | Linksys E5600 Login mesh_login.cgi improper authentication",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/vuln/430463"
            },
            {
              "name": "VDB-430463 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/430463/cti"
            },
            {
              "name": "CVE-2026-121615 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-121615"
            },
            {
              "name": "Submit #1023310 | Linksys E5600 1.1.0.26 Improper Authentication (CWE-287)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1023310"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Zimo-666/E5600-cves/tree/main/02-mesh-login-auth-bypass"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-03T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-03T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-03T17:45:08.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E5600 Login mesh_login.cgi improper authentication",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-121615",
        "datePublished": "2026-11-04T02:15:20.055Z",
        "dateReserved": "2026-11-03T16:39:51.588Z",
        "dateUpdated": "2026-11-09T16:22:51.368Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-120283 (GCVE-0-2026-120283)

    Vulnerability from cvelistv5 – Published: 2026-11-02 01:00 – Updated: 2026-11-02 14:24
    VLAI
    Title
    Linksys E8450 portal.cgi strcpy stack-based overflow
    Summary
    A vulnerability was identified in Linksys E8450 1.2.00.360516. Affected is the function strcpy of the file /www/cgi-bin/portal.cgi. Such manipulation of the argument hidden_timezone leads to stack-based buffer overflow. The attack can be executed remotely. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-02 14:23 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/vuln/429627 vdb-entrytechnical-description
    https://vuldb.com/vuln/429627/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-120283 third-party-advisory
    https://vuldb.com/submit/1014924 third-party-advisory
    https://www.linksys.com/ product
    Impacted products
    Vendor Product Version
    Linksys E8450 Affected: 1.2.00.360516
        cpe:2.3:o:linksys:e8450_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-120283",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-02T14:23:45.555931Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-02T14:24:28.643Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:e8450_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "E8450",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.00.360516"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "fanchai (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Linksys E8450 1.2.00.360516. Affected is the function strcpy of the file /www/cgi-bin/portal.cgi. Such manipulation of the argument hidden_timezone leads to stack-based buffer overflow. The attack can be executed remotely. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-02T01:00:22.303Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-429627 | Linksys E8450 portal.cgi strcpy stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/429627"
            },
            {
              "name": "VDB-429627 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/429627/cti"
            },
            {
              "name": "CVE-2026-120283 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-120283"
            },
            {
              "name": "Submit #1014924 | Linksys E8450 firmware 1.2.00.360516 Linksys E8450 portal.cgi hidden_timezone stack buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1014924"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-11-01T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-11-01T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-11-01T09:03:17.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E8450 portal.cgi strcpy stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202611"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-120283",
        "datePublished": "2026-11-02T01:00:22.303Z",
        "dateReserved": "2026-11-01T07:58:12.074Z",
        "dateUpdated": "2026-11-02T14:24:28.643Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2013-20009 (GCVE-0-2013-20009)

    Vulnerability from cvelistv5 – Published: 2026-10-28 02:03 – Updated: 2026-11-03 12:30
    VLAI
    Title
    Linksys WAG200G through 1.01.06 Stored XSS via policy_name Parameter
    Summary
    Linksys WAG200G through 1.01.06 contains a stored cross-site scripting vulnerability that allows authenticated attackers to inject scripts via the policy_name parameter in setup.cgi. Attackers can save a malicious policy name from the AccessRes.htm page that executes in administrators' browsers when viewing the Status > Wireless page.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-03 12:30 UTC
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    VulnCheck CNA
    References
    Impacted products
    Vendor Product Version
    Linksys WAG200G Affected: 0 , ≤ 1.01.06 (custom)
        cpe:2.3:h:linksys:wag200g:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2013-02-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2013-20009",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-03T12:30:21.110765Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-03T12:30:58.377Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WAG200G",
              "vendor": "Linksys",
              "versions": [
                {
                  "lessThanOrEqual": "1.01.06",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:h:linksys:wag200g:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "1.01.06",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Messner"
            }
          ],
          "datePublic": "2013-02-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Linksys WAG200G through 1.01.06 contains a stored cross-site scripting vulnerability that allows authenticated attackers to inject scripts via the policy_name parameter in setup.cgi. Attackers can save a malicious policy name from the AccessRes.htm page that executes in administrators\u0027 browsers when viewing the Status \u003e Wireless page."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-28T02:03:11.721Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "s3cur1ty Advisory m1adv2013-016: Linksys WAG200G Multiple Vulnerabilities",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.s3cur1ty.de/m1adv2013-016"
            },
            {
              "name": "ExploitDB-24476: Linksys WAG200G Multiple Vulnerabilities",
              "tags": [
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/24476"
            },
            {
              "name": "VulnCheck Advisory: Linksys WAG200G through 1.01.06 Stored XSS via policy_name Parameter",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/linksys-wag200g-through-1.01.06-stored-xss-via-policy-name-parameter"
            }
          ],
          "title": "Linksys WAG200G through 1.01.06 Stored XSS via policy_name Parameter",
          "x_generator": {
            "engine": "vulncheck-endgame"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2013-20009",
        "datePublished": "2026-10-28T02:03:11.721Z",
        "dateReserved": "2026-10-27T21:50:43.346Z",
        "dateUpdated": "2026-11-03T12:30:58.377Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2013-20008 (GCVE-0-2013-20008)

    Vulnerability from cvelistv5 – Published: 2026-10-28 02:03 – Updated: 2026-11-02 19:50
    VLAI
    Title
    Linksys WAG200G through 1.01.06 Admin Password Change Without Current Password
    Summary
    Linksys WAG200G through 1.01.06 contains a weak password change mechanism that allows attackers to change the administrator password without supplying the current password. Attackers with access to an authenticated administrator browser session can set a new password to lock out the legitimate administrator and take persistent device control.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-02 19:50 UTC
    CWE
    • CWE-620 - Unverified Password Change
    Assigner
    VulnCheck CNA
    References
    Impacted products
    Vendor Product Version
    Linksys WAG200G Affected: 0 , ≤ 1.01.06 (custom)
        cpe:2.3:h:linksys:wag200g:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2013-02-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2013-20008",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-02T19:50:07.009822Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-02T19:50:18.154Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WAG200G",
              "vendor": "Linksys",
              "versions": [
                {
                  "lessThanOrEqual": "1.01.06",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:h:linksys:wag200g:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "1.01.06",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Messner"
            }
          ],
          "datePublic": "2013-02-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Linksys WAG200G through 1.01.06 contains a weak password change mechanism that allows attackers to change the administrator password without supplying the current password. Attackers with access to an authenticated administrator browser session can set a new password to lock out the legitimate administrator and take persistent device control."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "PHYSICAL",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-620",
                  "description": "Unverified Password Change",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-28T02:03:11.024Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "s3cur1ty Advisory m1adv2013-016: Linksys WAG200G Multiple Vulnerabilities",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.s3cur1ty.de/m1adv2013-016"
            },
            {
              "name": "ExploitDB-24476: Linksys WAG200G Multiple Vulnerabilities",
              "tags": [
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/24476"
            },
            {
              "name": "VulnCheck Advisory: Linksys WAG200G through 1.01.06 Admin Password Change Without Current Password",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/linksys-wag200g-through-1.01.06-admin-password-change-without-current-password"
            }
          ],
          "title": "Linksys WAG200G through 1.01.06 Admin Password Change Without Current Password",
          "x_generator": {
            "engine": "vulncheck-endgame"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2013-20008",
        "datePublished": "2026-10-28T02:03:11.024Z",
        "dateReserved": "2026-10-27T21:50:43.346Z",
        "dateUpdated": "2026-11-02T19:50:18.154Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2013-20007 (GCVE-0-2013-20007)

    Vulnerability from cvelistv5 – Published: 2026-10-28 02:03 – Updated: 2026-11-05 15:30
    VLAI
    Title
    Linksys WAG200G through 1.01.06 OS Command Injection via timer_interval in setup.cgi
    Summary
    Linksys WAG200G through 1.01.06 contains an OS command injection vulnerability that allows authenticated attackers to execute commands by injecting backtick-delimited input into the timer_interval parameter. Attackers can send a crafted POST request to setup.cgi to start telnetd or download and run a backdoor, gaining full device control.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-05 15:30 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    VulnCheck CNA
    References
    Impacted products
    Vendor Product Version
    Linksys WAG200G Affected: 0 , ≤ 1.01.06 (custom)
        cpe:2.3:h:linksys:wag200g:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2013-02-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2013-20007",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-05T15:30:48.394745Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-05T15:30:56.238Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://www.s3cur1ty.de/m1adv2013-016"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WAG200G",
              "vendor": "Linksys",
              "versions": [
                {
                  "lessThanOrEqual": "1.01.06",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:h:linksys:wag200g:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "1.01.06",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Messner"
            }
          ],
          "datePublic": "2013-02-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Linksys WAG200G through 1.01.06 contains an OS command injection vulnerability that allows authenticated attackers to execute commands by injecting backtick-delimited input into the timer_interval parameter. Attackers can send a crafted POST request to setup.cgi to start telnetd or download and run a backdoor, gaining full device control."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-28T02:03:10.353Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "s3cur1ty Advisory m1adv2013-016: Linksys WAG200G Multiple Vulnerabilities",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.s3cur1ty.de/m1adv2013-016"
            },
            {
              "name": "ExploitDB-24476: Linksys WAG200G Multiple Vulnerabilities",
              "tags": [
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/24476"
            },
            {
              "name": "VulnCheck Advisory: Linksys WAG200G through 1.01.06 OS Command Injection via timer_interval in setup.cgi",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/linksys-wag200g-through-1.01.06-os-command-injection-via-timer-interval-in-setup-cgi"
            }
          ],
          "title": "Linksys WAG200G through 1.01.06 OS Command Injection via timer_interval in setup.cgi",
          "x_generator": {
            "engine": "vulncheck-endgame"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2013-20007",
        "datePublished": "2026-10-28T02:03:10.353Z",
        "dateReserved": "2026-10-27T21:50:43.346Z",
        "dateUpdated": "2026-11-05T15:30:56.238Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-114576 (GCVE-0-2026-114576)

    Vulnerability from cvelistv5 – Published: 2026-10-22 01:30 – Updated: 2026-10-23 21:16
    VLAI
    Title
    Linksys RE6250 Web Management strcmp random values
    Summary
    A vulnerability has been found in Linksys RE6250 1.0.04.001. This affects the function strcmp of the component Web Management Interface. The manipulation of the argument session_id leads to insufficiently random values. The attack may be initiated remotely. The complexity of an attack is rather high. It is indicated that the exploitability is difficult. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-23 18:00 UTC
    CWE
    • CWE-330 - Insufficiently Random Values
    • CWE-310 - Cryptographic Issues
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys RE6250 Affected: 1.0.04.001
        cpe:2.3:o:linksys:re6250_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-114576",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-23T18:00:49.882386Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-23T21:16:58.599Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:re6250_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "RE6250",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "bluerry (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Linksys RE6250 1.0.04.001. This affects the function strcmp of the component Web Management Interface. The manipulation of the argument session_id leads to insufficiently random values. The attack may be initiated remotely. The complexity of an attack is rather high. It is indicated that the exploitability is difficult. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 2.6,
                "vectorString": "AV:N/AC:H/Au:N/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-330",
                  "description": "Insufficiently Random Values",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-310",
                  "description": "Cryptographic Issues",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-22T01:30:21.675Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-424944 | Linksys RE6250 Web Management strcmp random values",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/424944"
            },
            {
              "name": "VDB-424944 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/424944/cti"
            },
            {
              "name": "CVE-2026-114576 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-114576"
            },
            {
              "name": "Submit #1021306 | Linksys RE6250 v1.0.04.001 Use of Insufficiently Random Values",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/1021306"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/b1uerry/cves/blob/main/Linksys/RE6250/Linksys_RE6250_predictable_sessionId/details.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-21T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-21T20:26:19.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys RE6250 Web Management strcmp random values",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-114576",
        "datePublished": "2026-10-22T01:30:21.675Z",
        "dateReserved": "2026-10-21T18:20:56.562Z",
        "dateUpdated": "2026-10-23T21:16:58.599Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-108896 (GCVE-0-2026-108896)

    Vulnerability from cvelistv5 – Published: 2026-10-12 14:30 – Updated: 2026-10-15 15:15
    VLAI
    Title
    Linksys E1700 setLinksysIpv6 os command injection
    Summary
    A vulnerability was found in Linksys E1700 1.0.0.4.003. This affects the function setLinksysIpv6 of the file /goform/setLinksysIpv6. The manipulation of the argument _6rd_prefix/_6rd_prefix_len results in os command injection. The attack can be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 14:54 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/vuln/416683 vdb-entrytechnical-description
    https://vuldb.com/vuln/416683/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-108896 third-party-advisory
    https://vuldb.com/submit/973115 third-party-advisory
    https://github.com/wudipjq/my_vuln/blob/main/Link… broken-linkexploit
    https://www.linksys.com/ product
    Impacted products
    Vendor Product Version
    Linksys E1700 Affected: 1.0.0.4.003
        cpe:2.3:o:linksys:e1700_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-108896",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T14:54:47.138428Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T15:15:07.266Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:e1700_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "E1700",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.4.003"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "pjqwudi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Linksys E1700 1.0.0.4.003. This affects the function setLinksysIpv6 of the file /goform/setLinksysIpv6. The manipulation of the argument _6rd_prefix/_6rd_prefix_len results in os command injection. The attack can be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-12T14:30:14.340Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-416683 | Linksys E1700 setLinksysIpv6 os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/416683"
            },
            {
              "name": "VDB-416683 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/416683/cti"
            },
            {
              "name": "CVE-2026-108896 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-108896"
            },
            {
              "name": "Submit #973115 | Linksys E1700 1.0.0.4.003 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/973115"
            },
            {
              "tags": [
                "broken-link",
                "exploit"
              ],
              "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys3/vuln_70/70.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-11T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-11T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-11T16:27:52.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E1700 setLinksysIpv6 os command injection",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-108896",
        "datePublished": "2026-10-12T14:30:14.340Z",
        "dateReserved": "2026-10-11T14:22:22.662Z",
        "dateUpdated": "2026-10-15T15:15:07.266Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-108895 (GCVE-0-2026-108895)

    Vulnerability from cvelistv5 – Published: 2026-10-12 14:15 – Updated: 2026-10-13 15:20
    VLAI
    Title
    Linksys E1700 setDMZ os command injection
    Summary
    A weakness has been identified in Linksys E1700 1.0.0.4.003. The affected element is the function setDMZ of the file /goform/setDMZ. Executing a manipulation of the argument MAC_addr can lead to os command injection. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-13 15:19 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys E1700 Affected: 1.0.0.4.003
        cpe:2.3:o:linksys:e1700_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-108895",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-13T15:19:46.719960Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-13T15:20:05.087Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:e1700_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "E1700",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.4.003"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "pjqwudi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Linksys E1700 1.0.0.4.003. The affected element is the function setDMZ of the file /goform/setDMZ. Executing a manipulation of the argument MAC_addr can lead to os command injection. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-12T14:15:10.292Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-416687 | Linksys E1700 setDMZ os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/416687"
            },
            {
              "name": "VDB-416687 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/416687/cti"
            },
            {
              "name": "CVE-2026-108895 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-108895"
            },
            {
              "name": "Submit #973114 | Linksys E1700 1.0.0.4.003 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/973114"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys3/vuln_69/69.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-11T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-11T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-11T16:28:09.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E1700 setDMZ os command injection",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-108895",
        "datePublished": "2026-10-12T14:15:10.292Z",
        "dateReserved": "2026-10-11T14:22:18.925Z",
        "dateUpdated": "2026-10-13T15:20:05.087Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-108894 (GCVE-0-2026-108894)

    Vulnerability from cvelistv5 – Published: 2026-10-12 14:00 – Updated: 2026-10-14 17:50
    VLAI
    Title
    Linksys E1700 Static Route addStaticRoute os command injection
    Summary
    A security flaw has been discovered in Linksys E1700 1.0.0.4.003. Impacted is the function addStaticRoute of the file /goform/addStaticRoute of the component Static Route Handler. Performing a manipulation of the argument staticRoute_IP_setting/staticRoute_Netmask_setting/staticRoute_Gateway_setting/staticRoute_Metric_setting results in os command injection. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-14 17:50 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys E1700 Affected: 1.0.0.4.003
        cpe:2.3:o:linksys:e1700_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-108894",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-14T17:50:01.386440Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-14T17:50:20.468Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:e1700_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Static Route Handler"
              ],
              "product": "E1700",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.4.003"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "pjqwudi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Linksys E1700 1.0.0.4.003. Impacted is the function addStaticRoute of the file /goform/addStaticRoute of the component Static Route Handler. Performing a manipulation of the argument staticRoute_IP_setting/staticRoute_Netmask_setting/staticRoute_Gateway_setting/staticRoute_Metric_setting results in os command injection. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-12T14:00:15.516Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-416686 | Linksys E1700 Static Route addStaticRoute os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/416686"
            },
            {
              "name": "VDB-416686 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/416686/cti"
            },
            {
              "name": "CVE-2026-108894 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-108894"
            },
            {
              "name": "Submit #973113 | Linksys E1700 1.0.0.4.003 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/973113"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys3/vuln_68/68.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-11T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-11T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-11T16:28:06.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E1700 Static Route addStaticRoute os command injection",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-108894",
        "datePublished": "2026-10-12T14:00:15.516Z",
        "dateReserved": "2026-10-11T14:22:15.579Z",
        "dateUpdated": "2026-10-14T17:50:20.468Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-108893 (GCVE-0-2026-108893)

    Vulnerability from cvelistv5 – Published: 2026-10-12 13:45 – Updated: 2026-10-13 18:25
    VLAI
    Title
    Linksys E1700 setVlan stack-based overflow
    Summary
    A vulnerability was identified in Linksys E1700 up to 1.0.0.4.003. This issue affects the function setVlan of the file /goform/setVlan. Such manipulation of the argument vlan_set leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-13 18:24 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys E1700 Affected: 1.0.0.4.003
        cpe:2.3:o:linksys:e1700_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-108893",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-13T18:24:47.776237Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-13T18:25:00.292Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:e1700_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "E1700",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.4.003"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "pjqwudi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Linksys E1700 up to 1.0.0.4.003. This issue affects the function setVlan of the file /goform/setVlan. Such manipulation of the argument vlan_set leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-12T13:45:15.796Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-416685 | Linksys E1700 setVlan stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/416685"
            },
            {
              "name": "VDB-416685 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/416685/cti"
            },
            {
              "name": "CVE-2026-108893 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-108893"
            },
            {
              "name": "Submit #973112 | Linksys E1700 1.0.0.4.003 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/973112"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys3/vuln_67/67.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-11T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-11T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-11T16:28:02.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E1700 setVlan stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-108893",
        "datePublished": "2026-10-12T13:45:15.796Z",
        "dateReserved": "2026-10-11T14:22:12.265Z",
        "dateUpdated": "2026-10-13T18:25:00.292Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-108892 (GCVE-0-2026-108892)

    Vulnerability from cvelistv5 – Published: 2026-10-12 13:30 – Updated: 2026-10-15 15:15
    VLAI
    Title
    Linksys E1700 Mac Filter ssid1MACFilter stack-based overflow
    Summary
    A vulnerability was determined in Linksys E1700 1.0.0.4.003. This vulnerability affects the function ssid1MACFilter of the file /goform/ssid1MACFilter of the component Mac Filter. This manipulation of the argument newap_text_%d causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 14:53 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys E1700 Affected: 1.0.0.4.003
        cpe:2.3:o:linksys:e1700_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-108892",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T14:53:59.774593Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T15:15:15.250Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:e1700_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Mac Filter"
              ],
              "product": "E1700",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.4.003"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "pjqwudi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Linksys E1700 1.0.0.4.003. This vulnerability affects the function ssid1MACFilter of the file /goform/ssid1MACFilter of the component Mac Filter. This manipulation of the argument newap_text_%d causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-12T13:30:16.430Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-416684 | Linksys E1700 Mac Filter ssid1MACFilter stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/416684"
            },
            {
              "name": "VDB-416684 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/416684/cti"
            },
            {
              "name": "CVE-2026-108892 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-108892"
            },
            {
              "name": "Submit #973111 | Linksys E1700 1.0.0.4.003 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/973111"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys3/vuln_66/66.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-10-11T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-10-11T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-10-11T16:27:58.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys E1700 Mac Filter ssid1MACFilter stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202610"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-108892",
        "datePublished": "2026-10-12T13:30:16.430Z",
        "dateReserved": "2026-10-11T14:22:08.723Z",
        "dateUpdated": "2026-10-15T15:15:15.250Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-86299 (GCVE-0-2026-86299)

    Vulnerability from cvelistv5 – Published: 2026-09-07 11:15 – Updated: 2026-09-11 20:35
    VLAI
    Title
    Linksys RE7000 PingTest json.cgi platform_event_pingTest os command injection
    Summary
    A vulnerability was detected in Linksys RE7000 2.0.15. This affects the function platform_event_pingTest of the file /cgi-bin/json.cgi?PingTest of the component PingTest Handler. The manipulation of the argument pingTestIp/pingTestPktSize/pingTestTimes results in os command injection. The attack can be launched remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-11 20:15 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys RE7000 Affected: 2.0.15
        cpe:2.3:o:linksys:re7000_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86299",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-11T20:15:44.006697Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-11T20:35:08.748Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:re7000_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "PingTest Handler"
              ],
              "product": "RE7000",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.15"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "sleep (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Linksys RE7000 2.0.15. This affects the function platform_event_pingTest of the file /cgi-bin/json.cgi?PingTest of the component PingTest Handler. The manipulation of the argument pingTestIp/pingTestPktSize/pingTestTimes results in os command injection. The attack can be launched remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-07T11:15:07.784Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399463 | Linksys RE7000 PingTest json.cgi platform_event_pingTest os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399463"
            },
            {
              "name": "VDB-399463 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399463/cti"
            },
            {
              "name": "CVE-2026-86299 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86299"
            },
            {
              "name": "Submit #906547 | Linksys RE7000 v2 2.0.15 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/906547"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/limou89/somevul/blob/main/Linksys_RE7000_v2_PingTest_Command_Injection.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-06T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-06T18:37:31.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys RE7000 PingTest json.cgi platform_event_pingTest os command injection",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86299",
        "datePublished": "2026-09-07T11:15:07.784Z",
        "dateReserved": "2026-09-06T16:32:18.951Z",
        "dateUpdated": "2026-09-11T20:35:08.748Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-6992 (GCVE-0-2026-6992)

    Vulnerability from cvelistv5 – Published: 2026-04-25 18:00 – Updated: 2026-04-27 13:34
    VLAI
    Title
    Linksys MR9600 JNAP Action run_central2.sh BTRequestGetSmartConnectStatus os command injection
    Summary
    A vulnerability was identified in Linksys MR9600 2.0.6.206937. This affects the function BTRequestGetSmartConnectStatus of the file /etc/init.d/run_central2.sh of the component JNAP Action Handler. The manipulation of the argument pin leads to os command injection. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-04-27 13:10 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/vuln/359544 vdb-entrytechnical-description
    https://vuldb.com/vuln/359544/cti signaturepermissions-required
    https://vuldb.com/submit/797086 third-party-advisory
    https://github.com/utmost3/cve/issues/2 exploitissue-tracking
    https://www.linksys.com/ product
    Impacted products
    Vendor Product Version
    Linksys MR9600 Affected: 2.0.6.206937
        cpe:2.3:o:linksys:mr9600_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-6992",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-27T13:10:55.443763Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-27T13:34:09.962Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:mr9600_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "JNAP Action Handler"
              ],
              "product": "MR9600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.6.206937"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wuuu (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Linksys MR9600 2.0.6.206937. This affects the function BTRequestGetSmartConnectStatus of the file /etc/init.d/run_central2.sh of the component JNAP Action Handler. The manipulation of the argument pin leads to os command injection. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-25T18:00:20.422Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-359544 | Linksys MR9600 JNAP Action run_central2.sh BTRequestGetSmartConnectStatus os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/359544"
            },
            {
              "name": "VDB-359544 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/359544/cti"
            },
            {
              "name": "Submit #797086 | Linksys MR9600 Firmware 2.0.6.206937 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/797086"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/utmost3/cve/issues/2"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-04-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-04-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-04-24T21:45:04.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys MR9600 JNAP Action run_central2.sh BTRequestGetSmartConnectStatus os command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-6992",
        "datePublished": "2026-04-25T18:00:20.422Z",
        "dateReserved": "2026-04-24T19:39:58.219Z",
        "dateUpdated": "2026-04-27T13:34:09.962Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-4558 (GCVE-0-2026-4558)

    Vulnerability from cvelistv5 – Published: 2026-03-22 17:29 – Updated: 2026-03-23 16:06
    VLAI
    Title
    Linksys MR9600 SmartConnect.lua smartConnectConfigure os command injection
    Summary
    A flaw has been found in Linksys MR9600 2.0.6.206937. Affected is the function smartConnectConfigure of the file SmartConnect.lua. Executing a manipulation of the argument configApSsid/configApPassphrase/srpLogin/srpPassword can lead to os command injection. The attack may be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-23 16:06 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.352385 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.352385 signaturepermissions-required
    https://vuldb.com/?submit.775036 third-party-advisory
    https://github.com/utmost3/cve/issues/1 exploitissue-tracking
    https://www.linksys.com/ product
    Impacted products
    Vendor Product Version
    Linksys MR9600 Affected: 2.0.6.206937
        cpe:2.3:o:linksys:mr9600_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-4558",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-23T16:06:42.703555Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-23T16:06:52.992Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:linksys:mr9600_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "MR9600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.6.206937"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wuuu (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Linksys MR9600 2.0.6.206937. Affected is the function smartConnectConfigure of the file SmartConnect.lua. Executing a manipulation of the argument configApSsid/configApPassphrase/srpLogin/srpPassword can lead to os command injection. The attack may be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-22T17:29:35.187Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-352385 | Linksys MR9600 SmartConnect.lua smartConnectConfigure os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.352385"
            },
            {
              "name": "VDB-352385 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.352385"
            },
            {
              "name": "Submit #775036 | Linksys MR9600 firmware 2.0.6.206937 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.775036"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/utmost3/cve/issues/1"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-03-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-03-21T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-03-21T21:52:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys MR9600 SmartConnect.lua smartConnectConfigure os command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-4558",
        "datePublished": "2026-03-22T17:29:35.187Z",
        "dateReserved": "2026-03-21T20:47:50.172Z",
        "dateUpdated": "2026-03-23T16:06:52.992Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-27850 (GCVE-0-2026-27850)

    Vulnerability from cvelistv5 – Published: 2026-02-25 16:58 – Updated: 2026-02-25 19:11
    VLAI
    Title
    Improper verification in Linksys MR9600, Linksys MX4200
    Summary
    Due to an improperly configured firewall rule, the router will accept any connection on the WAN port with the source port 5222, exposing all services which are normally only accessible through the local network. This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-25 19:11 UTC
    CWE
    • cwe-940 Improper Verification of Source of a Communication Channel
    Assigner
    ENISA CNA
    References
    URL Tags
    https://www.syss.de/fileadmin/dokumente/Publikati… third-party-advisorytechnical-description
    Impacted products
    Vendor Product Version
    Linksys MR9600 Affected: 1.0.4.205530
    Create a notification for this product.
    Linksys MX4200 Affected: 1.0.13.210200
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27850",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-25T19:11:25.500248Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-25T19:11:29.416Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "MR9600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.4.205530"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MX4200",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.13.210200"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Due to an improperly configured firewall rule, the router will accept any connection on the WAN port with the source port 5222, exposing all services which are normally only accessible through the local network.\u003cbr\u003e\u003cp\u003eThis issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.\u003c/p\u003e"
                }
              ],
              "value": "Due to an improperly configured firewall rule, the router will accept any connection on the WAN port with the source port 5222, exposing all services which are normally only accessible through the local network.\nThis issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "cwe-940 Improper Verification of Source of a Communication Channel",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-25T16:58:06.450Z",
            "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "shortName": "ENISA"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory",
                "technical-description"
              ],
              "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2025-014.txt"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Improper verification in Linksys MR9600, Linksys MX4200",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "assignerShortName": "ENISA",
        "cveId": "CVE-2026-27850",
        "datePublished": "2026-02-25T16:58:06.450Z",
        "dateReserved": "2026-02-24T07:07:48.974Z",
        "dateUpdated": "2026-02-25T19:11:29.416Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-27849 (GCVE-0-2026-27849)

    Vulnerability from cvelistv5 – Published: 2026-02-25 16:20 – Updated: 2026-02-26 16:47
    VLAI
    Title
    Missing neutralization in Linksys MR9600, Linksys MX4200
    Summary
    Due to missing neutralization of special elements, OS commands can be injected via the update functionality of a TLS-SRP connection, which is normally used for configuring devices inside the mesh network. This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-26 16:46 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    ENISA CNA
    References
    URL Tags
    https://www.syss.de/fileadmin/dokumente/Publikati… third-party-advisorytechnical-description
    Impacted products
    Vendor Product Version
    Linksys MR9600 Affected: 1.0.4.205530
    Create a notification for this product.
    Linksys MX4200 Affected: 1.0.13.210200
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27849",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-26T16:46:53.068105Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T16:47:01.147Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "MR9600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.4.205530"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MX4200",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.13.210200"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Due to missing neutralization of special elements, OS commands can be injected via the update functionality of a TLS-SRP connection, which is normally used for configuring devices inside the mesh network.\u003cbr\u003e\u003cp\u003eThis issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.\u003c/p\u003e"
                }
              ],
              "value": "Due to missing neutralization of special elements, OS commands can be injected via the update functionality of a TLS-SRP connection, which is normally used for configuring devices inside the mesh network.\nThis issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-25T16:20:25.395Z",
            "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "shortName": "ENISA"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory",
                "technical-description"
              ],
              "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2025-011.txt"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Missing neutralization in Linksys MR9600, Linksys MX4200",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "assignerShortName": "ENISA",
        "cveId": "CVE-2026-27849",
        "datePublished": "2026-02-25T16:20:25.395Z",
        "dateReserved": "2026-02-24T07:07:48.974Z",
        "dateUpdated": "2026-02-26T16:47:01.147Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-27848 (GCVE-0-2026-27848)

    Vulnerability from cvelistv5 – Published: 2026-02-25 15:15 – Updated: 2026-02-26 16:51
    VLAI
    Title
    Missing neutralization in Linksys MR9600, Linksys MX4200
    Summary
    Due to missing neutralization of special elements, OS commands can be injected via the handshake of a TLS-SRP connection, which are ultimately run as the root user. This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-26 16:50 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    ENISA CNA
    References
    URL Tags
    https://www.syss.de/fileadmin/dokumente/Publikati… third-party-advisorytechnical-description
    Impacted products
    Vendor Product Version
    Linksys MR9600 Affected: 1.0.4.205530
    Create a notification for this product.
    Linksys MX4200 Affected: 1.0.13.210200
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27848",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-26T16:50:25.890966Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T16:51:13.433Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "MR9600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.4.205530"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MX4200",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.13.210200"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Due to missing neutralization of special elements, OS commands can be injected via the handshake of a TLS-SRP connection, which are ultimately run as the root user.\u003cbr\u003e\u003cp\u003eThis issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.\u003c/p\u003e"
                }
              ],
              "value": "Due to missing neutralization of special elements, OS commands can be injected via the handshake of a TLS-SRP connection, which are ultimately run as the root user.\nThis issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-25T15:15:16.186Z",
            "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "shortName": "ENISA"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory",
                "technical-description"
              ],
              "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2025-010.txt"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Missing neutralization in Linksys MR9600, Linksys MX4200",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "assignerShortName": "ENISA",
        "cveId": "CVE-2026-27848",
        "datePublished": "2026-02-25T15:15:16.186Z",
        "dateReserved": "2026-02-24T07:07:48.974Z",
        "dateUpdated": "2026-02-26T16:51:13.433Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-27847 (GCVE-0-2026-27847)

    Vulnerability from cvelistv5 – Published: 2026-02-25 15:10 – Updated: 2026-02-26 16:56
    VLAI
    Title
    Missing authentication in Linksys MR9600, Linksys MX4200
    Summary
    Due to improper neutralization of special elements, SQL statements can be injected via the handshake of a TLS-SRP connection. This can be used to inject known credentials into the database that can be utilized to successfully complete the handshake and use the protected service. This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-26 16:55 UTC
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    ENISA CNA
    References
    URL Tags
    https://www.syss.de/fileadmin/dokumente/Publikati… third-party-advisorytechnical-description
    Impacted products
    Vendor Product Version
    Linksys MR9600 Affected: 1.0.4.205530
    Create a notification for this product.
    Linksys MX4200 Affected: 1.0.13.210200
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27847",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-26T16:55:30.669110Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-26T16:56:23.595Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "MR9600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.4.205530"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MX4200",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.13.210200"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Due to improper neutralization of special elements, SQL statements can be injected via the handshake of a TLS-SRP connection. This can be used to inject known credentials into the database that can be utilized to successfully complete the handshake and use the protected service.\u003cbr\u003e\u003cp\u003eThis issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.\u003c/p\u003e"
                }
              ],
              "value": "Due to improper neutralization of special elements, SQL statements can be injected via the handshake of a TLS-SRP connection. This can be used to inject known credentials into the database that can be utilized to successfully complete the handshake and use the protected service.\nThis issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-25T15:10:30.771Z",
            "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "shortName": "ENISA"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory",
                "technical-description"
              ],
              "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2025-009.txt"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Missing authentication in Linksys MR9600, Linksys MX4200",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "assignerShortName": "ENISA",
        "cveId": "CVE-2026-27847",
        "datePublished": "2026-02-25T15:10:30.771Z",
        "dateReserved": "2026-02-24T07:07:48.973Z",
        "dateUpdated": "2026-02-26T16:56:23.595Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-27846 (GCVE-0-2026-27846)

    Vulnerability from cvelistv5 – Published: 2026-02-25 15:03 – Updated: 2026-02-25 18:36
    VLAI
    Title
    Missing authentication in Linksys MR9600, Linksys MX4200
    Summary
    Due to missing authentication, a user with physical access to the device can misuse the mesh functionality for adding a new mesh device to the network  to gain access to sensitive information, including the password for admin access to the web interface and the Wi-Fi passwords.This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-25 18:35 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    ENISA CNA
    References
    URL Tags
    https://www.syss.de/fileadmin/dokumente/Publikati… third-party-advisorytechnical-description
    Impacted products
    Vendor Product Version
    Linksys MR9600 Affected: 1.0.4.205530
    Create a notification for this product.
    Linksys MX4200 Affected: 1.0.13.210200
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "NONE",
                  "baseScore": 6.2,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27846",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-25T18:35:57.582373Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-25T18:36:03.925Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "MR9600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.4.205530"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MX4200",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.13.210200"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Due to missing authentication, a user with physical access to the device can misuse the mesh functionality for adding a new mesh device to the network\u0026nbsp;\u003cbr\u003eto gain access to sensitive information, including the password for admin access to the web interface and the Wi-Fi passwords.\u003cp\u003eThis issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.\u003c/p\u003e"
                }
              ],
              "value": "Due to missing authentication, a user with physical access to the device can misuse the mesh functionality for adding a new mesh device to the network\u00a0\nto gain access to sensitive information, including the password for admin access to the web interface and the Wi-Fi passwords.This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-37",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-25T15:03:58.616Z",
            "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "shortName": "ENISA"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory",
                "technical-description"
              ],
              "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2025-002.txt"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Missing authentication in Linksys MR9600, Linksys MX4200",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "assignerShortName": "ENISA",
        "cveId": "CVE-2026-27846",
        "datePublished": "2026-02-25T15:03:58.616Z",
        "dateReserved": "2026-02-24T07:07:48.973Z",
        "dateUpdated": "2026-02-25T18:36:03.925Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-25603 (GCVE-0-2026-25603)

    Vulnerability from cvelistv5 – Published: 2026-02-24 17:14 – Updated: 2026-02-24 18:13
    VLAI
    Title
    Path Traversal vulnerability in Linksys MR9600, Linksys MX4200
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Linksys MR9600, Linksys MX4200 allows that contents of a USB drive partition can be mounted in an arbitrary location of the file system. This may result in the execution of shell scripts in the context of a root user.This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-02-24 18:11 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    ENISA CNA
    Impacted products
    Vendor Product Version
    Linksys MR9600 Affected: 1.0.4.205530
    Create a notification for this product.
    Linksys MX4200 Affected: 1.0.13.210200
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "PHYSICAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.6,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "REQUIRED",
                  "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-25603",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-24T18:11:45.463586Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-24T18:13:33.449Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "MR9600",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.4.205530"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MX4200",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.13.210200"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Linksys MR9600, Linksys MX4200 allows that\u0026nbsp;contents of a USB drive partition can be mounted in an arbitrary location of the file system. This may result in the execution of shell scripts in the context of a root user.\u003cp\u003eThis issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.\u003c/p\u003e"
                }
              ],
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Linksys MR9600, Linksys MX4200 allows that\u00a0contents of a USB drive partition can be mounted in an arbitrary location of the file system. This may result in the execution of shell scripts in the context of a root user.This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-251",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-251 Local Code Inclusion"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T17:14:36.141Z",
            "orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
            "shortName": "ENISA"
          },
          "references": [
            {
              "url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2025-001.txt"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Path Traversal vulnerability in Linksys MR9600, Linksys MX4200",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "assignerShortName": "ENISA",
        "cveId": "CVE-2026-25603",
        "datePublished": "2026-02-24T17:14:36.141Z",
        "dateReserved": "2026-02-03T07:24:49.548Z",
        "dateUpdated": "2026-02-24T18:13:33.449Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-52692 (GCVE-0-2025-52692)

    Vulnerability from cvelistv5 – Published: 2025-12-19 01:50 – Updated: 2025-12-19 15:37
    VLAI
    Title
    Bypass Authentication
    Summary
    Successful exploitation of the vulnerability could allow an attacker with local network access to send a specially crafted URL to access certain administration functions without login credentials.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-19 15:37 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    CSA CNA
    Impacted products
    Vendor Product Version
    Linksys Linksys E9450-SG Affected: 1.2.00.052
    Create a notification for this product.
    Date Public
    2025-12-19 01:50
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-52692",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-19T15:37:08.739165Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-306",
                    "description": "CWE-306 Missing Authentication for Critical Function",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-19T15:37:36.970Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Linksys E9450-SG",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.00.052"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Lam Jun Rong"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Javier Koh"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Joseph Teo"
            }
          ],
          "datePublic": "2025-12-19T01:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Successful exploitation of the vulnerability could allow an attacker with local network access to send a specially crafted URL to access certain administration functions without login credentials.\n\n\u003cp\u003e\u003c/p\u003e"
                }
              ],
              "value": "Successful exploitation of the vulnerability could allow an attacker with local network access to send a specially crafted URL to access certain administration functions without login credentials."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-19T01:50:58.469Z",
            "orgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
            "shortName": "CSA"
          },
          "references": [
            {
              "url": "https://www.csa.gov.sg/alerts-and-advisories/alerts/al-2025-118/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Bypass Authentication",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAs the Linksys E9450-SG has reached End-of-Life status, no firmware update is planned for this issue. Users and administrators of the affected product version are advised to:\u003c/p\u003e\u003cul\u003e\u003cli\u003eDisable remote administration\u003c/li\u003e\u003cli\u003eRestrict router management access to trusted devices on the local network\u003c/li\u003e\u003cli\u003eAvoid enabling Telnet access\u003c/li\u003e\u003cli\u003eConsider upgrading to a model actively supported by Linksys\u003c/li\u003e\u003c/ul\u003e"
                }
              ],
              "value": "As the Linksys E9450-SG has reached End-of-Life status, no firmware update is planned for this issue. Users and administrators of the affected product version are advised to:\n\n  *  Disable remote administration\n  *  Restrict router management access to trusted devices on the local network\n  *  Avoid enabling Telnet access\n  *  Consider upgrading to a model actively supported by Linksys"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
        "assignerShortName": "CSA",
        "cveId": "CVE-2025-52692",
        "datePublished": "2025-12-19T01:50:58.469Z",
        "dateReserved": "2025-06-19T06:04:41.987Z",
        "dateUpdated": "2025-12-19T15:37:36.970Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14136 (GCVE-0-2025-14136)

    Vulnerability from cvelistv5 – Published: 2025-12-06 13:02 – Updated: 2025-12-08 19:43
    VLAI
    Title
    Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow
    Summary
    A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-08 19:43 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys RE6500 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Linksys RE6250 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Linksys RE6300 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Linksys RE6350 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Linksys RE7000 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Linksys RE9000 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14136",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-08T19:43:52.124194Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-08T19:43:57.853Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RE6500",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            },
            {
              "product": "RE6250",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            },
            {
              "product": "RE6300",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            },
            {
              "product": "RE6350",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            },
            {
              "product": "RE7000",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            },
            {
              "product": "RE9000",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "pjqwudi (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-06T13:02:05.987Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-334525 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.334525"
            },
            {
              "name": "VDB-334525 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.334525"
            },
            {
              "name": "Submit #697983 | Linksys RE6500\u3001RE6250\u3001RE6300\u3001RE6350\u3001RE7000\u3001RE9000 RE6500(1.0.013.001)  RE6250(1.0.04.001)  RE6300(1.2.07.001)  RE6350(1.0.04.001)  RE7000(1.1.05.003)  RE9000(1.0.04.002) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.697983"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-12-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-12-05T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-12-05T18:12:31.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-14136",
        "datePublished": "2025-12-06T13:02:05.987Z",
        "dateReserved": "2025-12-05T17:07:21.569Z",
        "dateUpdated": "2025-12-08T19:43:57.853Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14135 (GCVE-0-2025-14135)

    Vulnerability from cvelistv5 – Published: 2025-12-06 11:32 – Updated: 2025-12-08 17:13
    VLAI
    Title
    Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so AP_get_wired_clientlist_setClientsName stack-based overflow
    Summary
    A vulnerability was identified in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function AP_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-08 17:06 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Linksys RE6500 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Linksys RE6250 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Linksys RE6300 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Linksys RE6350 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Linksys RE7000 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Linksys RE9000 Affected: 1.0.013.001
    Affected: 1.0.04.001
    Affected: 1.0.04.002
    Affected: 1.1.05.003
    Affected: 1.2.07.001
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14135",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-08T17:06:40.827143Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-08T17:13:59.221Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md#poc"
              },
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RE6500",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            },
            {
              "product": "RE6250",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            },
            {
              "product": "RE6300",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            },
            {
              "product": "RE6350",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            },
            {
              "product": "RE7000",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            },
            {
              "product": "RE9000",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.013.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.001"
                },
                {
                  "status": "affected",
                  "version": "1.0.04.002"
                },
                {
                  "status": "affected",
                  "version": "1.1.05.003"
                },
                {
                  "status": "affected",
                  "version": "1.2.07.001"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "pjqwudi (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function AP_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-06T11:32:06.505Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-334524 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so AP_get_wired_clientlist_setClientsName stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.334524"
            },
            {
              "name": "VDB-334524 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.334524"
            },
            {
              "name": "Submit #697982 | Linksys RE6500\u3001RE6250\u3001RE6300\u3001RE6350\u3001RE7000\u3001RE9000 RE6500(1.0.013.001)  RE6250(1.0.04.001)  RE6300(1.2.07.001)  RE6350(1.0.04.001)  RE7000(1.1.05.003)  RE9000(1.0.04.002) Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.697982"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-12-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-12-05T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-12-05T18:12:29.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so AP_get_wired_clientlist_setClientsName stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-14135",
        "datePublished": "2025-12-06T11:32:06.505Z",
        "dateReserved": "2025-12-05T17:07:18.585Z",
        "dateUpdated": "2025-12-08T17:13:59.221Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }