Search

Find a vulnerability

Search criteria

    4 vulnerabilities by lcds

    CVE-2024-5040 (GCVE-0-2024-5040)

    Vulnerability from cvelistv5 – Published: 2024-05-21 20:19 – Updated: 2024-08-01 21:03
    VLAI
    Title
    LCDS LAquis SCADA Path Traversal
    Summary
    There are multiple ways in LCDS LAquis SCADA for an attacker to access locations outside of their own directory.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-22 14:29 UTC
    CWE
    Assigner
    icscert CNA
    Impacted products
    Vendor Product Version
    LCDS LAquis SCADA Affected: 0 , ≤ 4.7.1.7 (custom)
    Create a notification for this product.
    lcds laquis_scada Affected: *
        cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "laquis_scada",
                "vendor": "lcds",
                "versions": [
                  {
                    "status": "affected",
                    "version": "*"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-5040",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-22T14:29:23.705386Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T18:02:51.586Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T21:03:10.607Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-142-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "LAquis SCADA",
              "vendor": "LCDS",
              "versions": [
                {
                  "lessThanOrEqual": "4.7.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\nThere are multiple ways in \nLCDS LAquis SCADA for an attacker to access locations outside of their own directory.\n\n"
                }
              ],
              "value": "There are multiple ways in \nLCDS LAquis SCADA for an attacker to access locations outside of their own directory."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Path Traversal",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-21T20:19:19.456Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-142-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\nLCDS recommends users update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://laquisscada.com/\"\u003eversion 4.7.1.371 or newer of LAquis SCADA.\u003c/a\u003e which has been configured to resolve the reported path traversal issues.\n\n\u003cbr\u003e"
                }
              ],
              "value": "LCDS recommends users update to  version 4.7.1.371 or newer of LAquis SCADA. https://laquisscada.com/  which has been configured to resolve the reported path traversal issues."
            }
          ],
          "source": {
            "advisory": "ICSA-24-142-01",
            "discovery": "EXTERNAL"
          },
          "title": "LCDS LAquis SCADA Path Traversal",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-5040",
        "datePublished": "2024-05-21T20:19:19.456Z",
        "dateReserved": "2024-05-16T23:41:33.314Z",
        "dateUpdated": "2024-08-01T21:03:10.607Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-19029 (GCVE-0-2018-19029)

    Vulnerability from cvelistv5 – Published: 2019-02-05 18:00 – Updated: 2024-09-16 22:25
    VLAI
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash.
    Severity
    No CVSS data available.
    CWE
    • CWE-822 - UNTRUSTED POINTER DEREFERENCE CWE-822
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    LCDS LCDS Laquis SCADA Affected: All versions prior to version 4.1.0.4150
    Create a notification for this product.
    Date Public
    2019-01-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:23:08.951Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
              },
              {
                "name": "106634",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/106634"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "LCDS",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "datePublic": "2019-01-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-822",
                  "description": "UNTRUSTED POINTER DEREFERENCE CWE-822",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-02-06T10:57:02.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
            },
            {
              "name": "106634",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/106634"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2019-01-15T00:00:00",
              "ID": "CVE-2018-19029",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LCDS Laquis SCADA",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to version 4.1.0.4150"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "LCDS"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "UNTRUSTED POINTER DEREFERENCE CWE-822"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
                },
                {
                  "name": "106634",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/106634"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-19029",
        "datePublished": "2019-02-05T18:00:00.000Z",
        "dateReserved": "2018-11-06T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:25:18.489Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-19002 (GCVE-0-2018-19002)

    Vulnerability from cvelistv5 – Published: 2019-02-05 18:00 – Updated: 2024-09-16 20:27
    VLAI
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash.
    Severity
    No CVSS data available.
    CWE
    • CWE-94 - IMPROPER CONTROL OF GENERATION OF CODE ('CODE INJECTION') CWE-94
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    LCDS LCDS Laquis SCADA Affected: All versions prior to version 4.1.0.4150
    Create a notification for this product.
    Date Public
    2019-01-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:23:08.797Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
              },
              {
                "name": "106634",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/106634"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "LCDS",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "datePublic": "2019-01-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-94",
                  "description": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-02-06T10:57:02.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
            },
            {
              "name": "106634",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/106634"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2019-01-15T00:00:00",
              "ID": "CVE-2018-19002",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LCDS Laquis SCADA",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to version 4.1.0.4150"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "LCDS"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
                },
                {
                  "name": "106634",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/106634"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-19002",
        "datePublished": "2019-02-05T18:00:00.000Z",
        "dateReserved": "2018-11-06T00:00:00.000Z",
        "dateUpdated": "2024-09-16T20:27:21.831Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18986 (GCVE-0-2018-18986)

    Vulnerability from cvelistv5 – Published: 2019-02-05 18:00 – Updated: 2024-09-17 00:17
    VLAI
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution.
    Severity
    No CVSS data available.
    CWE
    • CWE-787 - OUT-OF-BOUNDS WRITE CWE-787
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    LCDS LCDS Laquis SCADA Affected: All versions prior to version 4.1.0.4150
    Create a notification for this product.
    Date Public
    2019-01-15 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:23:08.495Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
              },
              {
                "name": "106634",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/106634"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "LCDS",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "datePublic": "2019-01-15T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "OUT-OF-BOUNDS WRITE CWE-787",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-02-06T10:57:02.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
            },
            {
              "name": "106634",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/106634"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2019-01-15T00:00:00",
              "ID": "CVE-2018-18986",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LCDS Laquis SCADA",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions prior to version 4.1.0.4150"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "LCDS"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "OUT-OF-BOUNDS WRITE CWE-787"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
                },
                {
                  "name": "106634",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/106634"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-18986",
        "datePublished": "2019-02-05T18:00:00.000Z",
        "dateReserved": "2018-11-06T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:17:11.349Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }