Refine your search
3 vulnerabilities found for by Semtech
CVE-2025-14859 (GCVE-0-2025-14859)
Vulnerability from cvelistv5
Published
2026-04-07 19:58
Modified
2026-04-07 20:42
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Summary
The Semtech LR11xx LoRa transceivers implement secure boot functionality using digital signatures to authenticate firmware. However, the implementation uses a non-standard cryptographic hashing algorithm that is vulnerable to second preimage attacks. An attacker with physical access to the device can exploit this weakness to generate a malicious firmware image with a hash collision, bypassing the secure boot verification mechanism and installing arbitrary unauthorized firmware on the device.
References
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-14859",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-07T20:31:39.343091Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-07T20:42:41.142Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"firmware"
],
"product": "LR1110",
"vendor": "Semtech",
"versions": [
{
"lessThan": "BL2 FW 0x1001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "LR1120",
"vendor": "Semtech",
"versions": [
{
"lessThan": "BL2 FW 0x2001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "LR1121",
"vendor": "Semtech",
"versions": [
{
"lessThan": "BL2 FW 0x2101",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:semtech:lr1110:*:*:*:*:*:*:*:*",
"versionEndExcluding": "bl2_fw_0x1001",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:semtech:lr1120:*:*:*:*:*:*:*:*",
"versionEndExcluding": "bl2_fw_0x2001",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:semtech:lr1121:*:*:*:*:*:*:*:*",
"versionEndExcluding": "bl2_fw_0x2101",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"datePublic": "2026-04-06T18:07:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Semtech LR11xx LoRa transceivers implement secure boot functionality using digital signatures to authenticate firmware. However, the implementation uses a non-standard cryptographic hashing algorithm that is vulnerable to second preimage attacks. An attacker with physical access to the device can exploit this weakness to generate a malicious firmware image with a hash collision, bypassing the secure boot verification mechanism and installing arbitrary unauthorized firmware on the device.\n\n\u003cbr\u003e"
}
],
"value": "The Semtech LR11xx LoRa transceivers implement secure boot functionality using digital signatures to authenticate firmware. However, the implementation uses a non-standard cryptographic hashing algorithm that is vulnerable to second preimage attacks. An attacker with physical access to the device can exploit this weakness to generate a malicious firmware image with a hash collision, bypassing the secure boot verification mechanism and installing arbitrary unauthorized firmware on the device."
}
],
"impacts": [
{
"capecId": "CAPEC-68",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-68 Subvert Code-signing"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "IRRECOVERABLE",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "PHYSICAL",
"baseScore": 7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "CONCENTRATED",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:N/AU:N/R:I/V:C/RE:M",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327 Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-07T19:58:41.379Z",
"orgId": "747bec18-acd0-4d99-a5c8-5e366c66ab7e",
"shortName": "SWI"
},
"references": [
{
"url": "https://www.semtech.com/company/security/security-bulletins/sem-psa-2026-001"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Semtech LR11xx Secure Boot Bypass",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "747bec18-acd0-4d99-a5c8-5e366c66ab7e",
"assignerShortName": "SWI",
"cveId": "CVE-2025-14859",
"datePublished": "2026-04-07T19:58:41.379Z",
"dateReserved": "2025-12-18T00:09:40.606Z",
"dateUpdated": "2026-04-07T20:42:41.142Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-14858 (GCVE-0-2025-14858)
Vulnerability from cvelistv5
Published
2026-04-07 19:57
Modified
2026-04-07 20:42
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-226 - Sensitive Information in Resource Not Removed Before Reuse
Summary
The Semtech LR11xx LoRa transceivers running early versions of firmware contains an information disclosure vulnerability in its firmware validation functionality. When a host issues a firmware validity check command via the SPI interface, the device decrypts the provided encrypted firmware package block-by-block to validate its integrity. However, the last decrypted firmware block remains uncleared in memory after the validation process completes. An attacker with access to the SPI interface can subsequently issue memory read commands to retrieve the decrypted firmware contents from this residual memory, effectively bypassing the firmware encryption protection mechanism. The attack requires physical access to the device's SPI interface.
References
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-14858",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-07T20:31:31.087152Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-07T20:42:41.321Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"firmware"
],
"product": "LR1110",
"vendor": "Semtech",
"versions": [
{
"lessThan": "TRX FW 0x0402",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "LR1120",
"vendor": "Semtech",
"versions": [
{
"lessThan": "TRX FW 0x0202",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "LR1121",
"vendor": "Semtech",
"versions": [
{
"lessThan": "TRX FW 0x0104",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:semtech:lr1110:*:*:*:*:*:*:*:*",
"versionEndExcluding": "trx_fw_0x0402",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:semtech:lr1120:*:*:*:*:*:*:*:*",
"versionEndExcluding": "trx_fw_0x0202",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:semtech:lr1121:*:*:*:*:*:*:*:*",
"versionEndExcluding": "trx_fw_0x0104",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Egor (radioegor146) Koleda, https://github.com/radioegor146"
}
],
"datePublic": "2026-04-06T18:07:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Semtech LR11xx LoRa transceivers running early versions of firmware contains an information disclosure vulnerability in its firmware validation functionality. When a host issues a firmware validity check command via the SPI interface, the device decrypts the provided encrypted firmware package block-by-block to validate its integrity. However, the last decrypted firmware block remains uncleared in memory after the validation process completes. An attacker with access to the SPI interface can subsequently issue memory read commands to retrieve the decrypted firmware contents from this residual memory, effectively bypassing the firmware encryption protection mechanism. The attack requires physical access to the device\u0027s SPI interface.\u003cbr\u003e"
}
],
"value": "The Semtech LR11xx LoRa transceivers running early versions of firmware contains an information disclosure vulnerability in its firmware validation functionality. When a host issues a firmware validity check command via the SPI interface, the device decrypts the provided encrypted firmware package block-by-block to validate its integrity. However, the last decrypted firmware block remains uncleared in memory after the validation process completes. An attacker with access to the SPI interface can subsequently issue memory read commands to retrieve the decrypted firmware contents from this residual memory, effectively bypassing the firmware encryption protection mechanism. The attack requires physical access to the device\u0027s SPI interface."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37 Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "AUTOMATIC",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "PHYSICAL",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "CONCENTRATED",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/AU:N/R:A/V:C/RE:M",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-226",
"description": "CWE-226 Sensitive Information in Resource Not Removed Before Reuse",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-07T19:57:43.422Z",
"orgId": "747bec18-acd0-4d99-a5c8-5e366c66ab7e",
"shortName": "SWI"
},
"references": [
{
"url": "https://www.semtech.com/company/security/security-bulletins/sem-psa-2026-001"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Semtech LR11xx Encrypted Firmware Disclosure",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "747bec18-acd0-4d99-a5c8-5e366c66ab7e",
"assignerShortName": "SWI",
"cveId": "CVE-2025-14858",
"datePublished": "2026-04-07T19:57:43.422Z",
"dateReserved": "2025-12-18T00:09:38.279Z",
"dateUpdated": "2026-04-07T20:42:41.321Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-14857 (GCVE-0-2025-14857)
Vulnerability from cvelistv5
Published
2026-04-07 19:56
Modified
2026-04-07 20:42
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-123 - Write-what-where Condition
Summary
An improper access control vulnerability exists in Semtech LoRa LR11xxx transceivers running early versions of firmware where the memory write command accessible via the physical SPI interface fails to enforce write protection on the program call stack. An attacker with physical access to the SPI interface can overwrite stack memory to hijack program control flow and achieve limited arbitrary code execution. However, the impact is limited to the active attack session: the device's secure boot mechanism prevents persistent firmware modification, the crypto engine isolates cryptographic keys from direct firmware access, and all modifications are lost upon device reboot or loss of physical access.
References
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-14857",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-07T20:31:21.612362Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-07T20:42:41.466Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"firmware"
],
"product": "LR1110",
"vendor": "Semtech",
"versions": [
{
"lessThan": "TRX FW 0x0402",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "LR1120",
"vendor": "Semtech",
"versions": [
{
"lessThan": "TRX FW 0x0202",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "LR1121",
"vendor": "Semtech",
"versions": [
{
"lessThan": "TRX FW 0x0104",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:semtech:lr1110:*:*:*:*:*:*:*:*",
"versionEndExcluding": "trx_fw_0x0402",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:semtech:lr1120:*:*:*:*:*:*:*:*",
"versionEndExcluding": "trx_fw_0x0202",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:semtech:lr1121:*:*:*:*:*:*:*:*",
"versionEndExcluding": "trx_fw_0x0104",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Egor (radioegor146) Koleda, https://github.com/radioegor146"
}
],
"datePublic": "2026-04-06T18:07:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An improper access control vulnerability exists in Semtech LoRa LR11xxx transceivers running early versions of firmware where the memory write command accessible via the physical SPI interface fails to enforce write protection on the program call stack. An attacker with physical access to the SPI interface can overwrite stack memory to hijack program control flow and achieve limited arbitrary code execution. However, the impact is limited to the active attack session: the device\u0027s secure boot mechanism prevents persistent firmware modification, the crypto engine isolates cryptographic keys from direct firmware access, and all modifications are lost upon device reboot or loss of physical access.\u003cbr\u003e"
}
],
"value": "An improper access control vulnerability exists in Semtech LoRa LR11xxx transceivers running early versions of firmware where the memory write command accessible via the physical SPI interface fails to enforce write protection on the program call stack. An attacker with physical access to the SPI interface can overwrite stack memory to hijack program control flow and achieve limited arbitrary code execution. However, the impact is limited to the active attack session: the device\u0027s secure boot mechanism prevents persistent firmware modification, the crypto engine isolates cryptographic keys from direct firmware access, and all modifications are lost upon device reboot or loss of physical access."
}
],
"impacts": [
{
"capecId": "CAPEC-679",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-679 Exploitation of Improperly Configured or Implemented Memory Protections"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "AUTOMATIC",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "PHYSICAL",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:N/AU:N/R:A/V:D/RE:M",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-123",
"description": "CWE-123 Write-what-where Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-07T19:56:59.042Z",
"orgId": "747bec18-acd0-4d99-a5c8-5e366c66ab7e",
"shortName": "SWI"
},
"references": [
{
"url": "https://www.semtech.com/company/security/security-bulletins/sem-psa-2026-001"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Semtech LR11xx Memory Write Access Control Bypass",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "747bec18-acd0-4d99-a5c8-5e366c66ab7e",
"assignerShortName": "SWI",
"cveId": "CVE-2025-14857",
"datePublished": "2026-04-07T19:56:59.042Z",
"dateReserved": "2025-12-18T00:09:25.318Z",
"dateUpdated": "2026-04-07T20:42:41.466Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}