Refine your search

2 vulnerabilities found for by LITE-ON Technology Corporation

CVE-2026-80217 (GCVE-0-2026-80217)
Vulnerability from cvelistv5
Published
2026-09-15 08:50
Modified
2026-09-15 13:21
CWE
Summary
Hidden functionality issue exists in FF-RFI079I4 and FF-RFI078I4, which may allow a user who can log in via SSH and access the enable mode on the product to execute arbitrary OS commands.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-80217",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-15T13:20:27.171964Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-15T13:21:42.918Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FF-RFI079I4",
          "vendor": "LITE-ON Technology Corporation",
          "versions": [
            {
              "lessThan": "02.01.15",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FF-RFI078I4",
          "vendor": "LITE-ON Technology Corporation",
          "versions": [
            {
              "lessThan": "02.01.15",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Hidden functionality issue exists in FF-RFI079I4 and FF-RFI078I4, which may allow a user who can log in via SSH and access the enable mode on the product to execute arbitrary OS commands."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-912",
              "description": "Hidden functionality",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-15T08:50:13.630Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://jvn.jp/en/jp/JVN02049764/"
        },
        {
          "url": "https://5g.liteon.com/security/flexfi/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2026-80217",
    "datePublished": "2026-09-15T08:50:13.630Z",
    "dateReserved": "2026-09-07T08:29:55.575Z",
    "dateUpdated": "2026-09-15T13:21:42.918Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-77853 (GCVE-0-2026-77853)
Vulnerability from cvelistv5
Published
2026-09-15 08:49
Modified
2026-09-15 13:31
CWE
  • CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
Summary
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in FF-RFI079I4 and FF-RFI078I4. A user who can log in to the product's M-Plane (NETCONF) may execute arbitrary OS commands.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-77853",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-15T13:30:26.116157Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-15T13:31:40.999Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FF-RFI079I4",
          "vendor": "LITE-ON Technology Corporation",
          "versions": [
            {
              "lessThan": "02.01.15",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FF-RFI078I4",
          "vendor": "LITE-ON Technology Corporation",
          "versions": [
            {
              "lessThan": "02.01.15",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in FF-RFI079I4 and FF-RFI078I4. A user who can log in to the product\u0027s M-Plane (NETCONF) may execute arbitrary OS commands."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-15T08:49:58.307Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://5g.liteon.com/security/flexfi/"
        },
        {
          "url": "https://jvn.jp/en/jp/JVN02049764/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2026-77853",
    "datePublished": "2026-09-15T08:49:58.307Z",
    "dateReserved": "2026-09-07T08:29:54.584Z",
    "dateUpdated": "2026-09-15T13:31:40.999Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}