Refine your search

2 vulnerabilities found for by Johnson Control

CVE-2026-21655 (GCVE-0-2026-21655)
Vulnerability from cvelistv5
Published
2026-07-23 20:13
Modified
2026-08-06 17:49
CWE
  • CWE-502 - Deserialization of untrusted data
Summary
Deserialization of untrusted data vulnerability in Johnson Control victor on Windows, Johnson Controls CCure 9000, and Johnson Controls Victor Application Server allows capec-586. This issue affects victor: before 8.0; CCure 9000: before 3.2; Victor Application Server: before 4.1.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-21655",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-24T13:34:37.830872Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-24T13:34:45.585Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "victor",
          "vendor": "Johnson Control",
          "versions": [
            {
              "lessThan": "8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CCure 9000",
          "vendor": "Johnson Controls",
          "versions": [
            {
              "lessThan": "3.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Victor Application Server",
          "vendor": "Johnson Controls",
          "versions": [
            {
              "lessThan": "4.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:johnson_control:victor:*:*:windows:*:*:*:*:*",
                  "versionEndExcluding": "8.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:johnson_controls:ccure_9000:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "3.2",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:johnson_controls:victor_application_server:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "4.1",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "datePublic": "2026-07-23T20:06:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Deserialization of untrusted data vulnerability in Johnson Control victor on Windows, Johnson Controls CCure 9000, and Johnson Controls Victor Application Server allows capec-586.\u003cp\u003eThis issue affects victor: before 8.0; CCure 9000: before 3.2; Victor Application Server: before 4.1.\u003c/p\u003e"
            }
          ],
          "value": "Deserialization of untrusted data vulnerability in Johnson Control victor on Windows, Johnson Controls CCure 9000, and Johnson Controls Victor Application Server allows capec-586.\n\nThis issue affects victor: before 8.0; CCure 9000: before 3.2; Victor Application Server: before 4.1."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "capec-586"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-502",
              "description": "CWE-502 Deserialization of untrusted data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-06T17:49:48.709Z",
        "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "shortName": "jci"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "C-CURE 9000 and Victor application server - Deserialization of Untrusted Data",
      "x_generator": {
        "engine": "Vulnogram 1.0.4"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
    "assignerShortName": "jci",
    "cveId": "CVE-2026-21655",
    "datePublished": "2026-07-23T20:13:05.447Z",
    "dateReserved": "2026-01-02T13:23:28.169Z",
    "dateUpdated": "2026-08-06T17:49:48.709Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-43873 (GCVE-0-2025-43873)
Vulnerability from cvelistv5
Published
2025-12-17 15:53
Modified
2026-08-24 20:33
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
Successful exploitation of these vulnerabilities could allow an attacker to modify firmware and gain full access to the device.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43873",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-17T16:42:09.310159Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-17T16:42:19.977Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "iSTAR Ultra, iSTAR Ultra SE, iSTAR Ultra G2, iSTAR Ultra G2 SE, iSTAR Edge G2",
          "vendor": "Johnson Control",
          "versions": [
            {
              "lessThanOrEqual": "6.9.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Reid Wightman of Dragos reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2025-12-12T15:43:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan\u003eSuccessful exploitation of these vulnerabilities could allow an attacker to modify firmware and gain full access to the device.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Successful exploitation of these vulnerabilities could allow an attacker to modify firmware and gain full access to the device."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88: OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-24T20:33:56.817Z",
        "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "shortName": "jci"
      },
      "references": [
        {
          "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-345-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cul\u003e\u003cli\u003eUpgrade iSTAR Ultra, iSTAR Ultra SE, iStar Ultra LT to version 6.9.7.CU01 or greater.\u003c/li\u003e\u003cli\u003eUpgrade iSTAR Ultra G2, iSTAR Ultra G2 SE, iSTAR Edge G2 to version 6.9.3 or greater.\u0026nbsp;\u0026nbsp;\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "*  Upgrade iSTAR Ultra, iSTAR Ultra SE, iStar Ultra LT to version 6.9.7.CU01 or greater.\n  *  Upgrade iSTAR Ultra G2, iSTAR Ultra G2 SE, iSTAR Edge G2 to version 6.9.3 or greater."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "iSTAR Ultra, Ultra SE, Ultra G2, Ultra G2 SE, iSTAR Edge G2 - Authenticated web application command injection - setFaultDebounce",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
    "assignerShortName": "jci",
    "cveId": "CVE-2025-43873",
    "datePublished": "2025-12-17T15:53:04.477Z",
    "dateReserved": "2025-04-17T20:07:25.122Z",
    "dateUpdated": "2026-08-24T20:33:56.817Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}