Refine your search

48 vulnerabilities found for by Hikvision

CVE-2026-85543 (GCVE-0-2026-85543)
Vulnerability from cvelistv5
Published
2026-09-10 12:47
Modified
2026-09-10 14:40
Summary
Some Wi-Fi series camera products have insufficient permission validation on certain interfaces, allowing authenticated low-privileged users to obtain device Wi-Fi configuration information through these interfaces.
Impacted products
Vendor Product Version
Hikvision Wi-Fi series camera Version: https://www.hikvision.com/content/dam/hikvision/en/support/download/firmware/ipc/cve-temp-fw/Network-Camera-V5.7.26-Release-Note-E8.pdf
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-85543",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-10T14:38:56.286403Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-285",
                "description": "CWE-285 Improper Authorization",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-10T14:40:09.499Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Wi-Fi series camera",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/content/dam/hikvision/en/support/download/firmware/ipc/cve-temp-fw/Network-Camera-V5.7.26-Release-Note-E8.pdf",
              "versionType": "link"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dmitry Gorelikov"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Some Wi-Fi series camera products have insufficient permission validation on certain interfaces, allowing authenticated low-privileged users to obtain device Wi-Fi configuration information through these interfaces."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-10T12:47:29.537Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/content/dam/hikvision/en/support/download/firmware/ipc/cve-temp-fw/Network-Camera-V5.7.26-Release-Note-E8.pdf"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-85543",
    "datePublished": "2026-09-10T12:47:29.537Z",
    "dateReserved": "2026-09-04T09:24:07.712Z",
    "dateUpdated": "2026-09-10T14:40:09.499Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-85545 (GCVE-0-2026-85545)
Vulnerability from cvelistv5
Published
2026-09-10 12:27
Modified
2026-09-10 14:46
Summary
There is an Vulnerability in some HikCentral Access Control versions. Authenticated low-privilege users can invoke API interfaces that their role is not authorized to access.
Impacted products
Vendor Product Version
Hikvision HikCentral Access Control Version: below V2.5.0(included)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-85545",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-10T14:43:50.946498Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-10T14:46:23.183Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HikCentral Access Control",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "below V2.5.0(included)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Patrick Tung (@patrickt2017)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is an Vulnerability in some HikCentral Access Control versions. Authenticated low-privilege users can invoke API interfaces that their role is not authorized to access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-10T12:27:07.037Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-hikcentral-access-control"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-85545",
    "datePublished": "2026-09-10T12:27:07.037Z",
    "dateReserved": "2026-09-04T09:24:07.712Z",
    "dateUpdated": "2026-09-10T14:46:23.183Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-85544 (GCVE-0-2026-85544)
Vulnerability from cvelistv5
Published
2026-09-10 12:26
Modified
2026-09-18 09:39
CWE
  • CWE-798 - Use of Hard-coded Credentials
Summary
Some Hikvision intercom products utilize an immutable factory value which should be obtained from local network or physical interaction with the device within their main card, which may allow attackers to forge a legitimate main card, thereby gaining the permission to issue cards.
Impacted products
Vendor Product Version
Hikvision DS-KV9503 Version: V2.3.13 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KV6113 Version: V3.7.0 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KV6103 Version: V3.7.0 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KV6133 Version: V3.7.0 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KV8113 Version: V3.7.0 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KV8213 Version: V3.7.0 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KV8413 Version: V3.7.0 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KD8003 Version: V3.7.1 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KD8005 Version: V3.10.0 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KV6114 Version: V3.9.0 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KV6124 Version: V3.9.0 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KV6134 Version: V3.9.0 and the versions prior to it
Create a notification for this product.
   Hikvision DS-KV8114 Version: V3.11.0 and the versions prior to it
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-85544",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-10T14:51:42.740079Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-1310",
                "description": "CWE-1310 Missing Ability to Patch ROM Code",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-10T14:52:28.338Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-KV9503",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V2.3.13 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KV6113",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.7.0 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KV6103",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.7.0 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KV6133",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.7.0 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KV8113",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.7.0 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KV8213",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.7.0 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KV8413",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.7.0 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KD8003",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.7.1 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KD8005",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.10.0 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KV6114",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.9.0 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KV6124",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.9.0 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KV6134",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.9.0 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-KV8114",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V3.11.0 and the versions prior to it"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Filipe Moreira"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Some Hikvision intercom products utilize an immutable factory value which should be obtained from local network or physical interaction with the device within their main card, which may allow attackers to forge a legitimate main card, thereby gaining the permission to issue cards."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-18T09:39:16.889Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikvision-intercom-products"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-85544",
    "datePublished": "2026-09-10T12:26:00.396Z",
    "dateReserved": "2026-09-04T09:24:07.712Z",
    "dateUpdated": "2026-09-18T09:39:16.889Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-16843 (GCVE-0-2026-16843)
Vulnerability from cvelistv5
Published
2026-07-31 09:31
Modified
2026-08-03 05:56
Summary
Some Hikvision Networking Products are vulnerable to authenticated command execution due to insufficient input validation. Attackers with valid credentials can exploit this flaw by sending crafted packets containing malicious commands to affected devices, leading to arbitrary command execution.
Impacted products
Vendor Product Version
Hikvision DS-3WAP521-SI Version: V1.1.6601 build251223 and earlier
Create a notification for this product.
   Hikvision DS-3WAP522-SI Version: V1.1.6601 build251223 and earlier
Create a notification for this product.
   Hikvision DS-3WAP621E-SI Version: V1.1.6601 build251223 and earlier
Create a notification for this product.
   Hikvision DS-3WAP622E-SI Version: V1.1.6601 build251223 and earlier
Create a notification for this product.
   Hikvision DS-3WAP623E-SI Version: V1.1.6601 build251223 and earlier
Create a notification for this product.
   Hikvision DS-3WAP622G-SI Version: V1.1.6601 build251223 and earlier
Create a notification for this product.
   Hikvision DS-3WG105G-SI Version: V1.1.6601 build251223 and earlier
Create a notification for this product.
   Hikvision DS-3WG105GP-SI Version: V1.1.6601 build251223 and earlier
Create a notification for this product.
   Hikvision DS-3WG210GP-SI Version: V1.1.6601 build251223 and earlier
Create a notification for this product.
   Hikvision DS-3WG507G-SI Version: V1.1.6601 build251223 and earlier
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-16843",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-31T16:31:03.018086Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-78",
                "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-31T16:31:37.052Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-3WAP521-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6601 build251223 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WAP522-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6601 build251223 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WAP621E-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6601 build251223 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WAP622E-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6601 build251223 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WAP623E-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6601 build251223 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WAP622G-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6601 build251223 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WG105G-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6601 build251223 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WG105GP-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6601 build251223 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WG210GP-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6601 build251223 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WG507G-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6601 build251223 and earlier"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "independent security researcher exzettabyte"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Some Hikvision Networking Products are vulnerable to authenticated command execution due to insufficient input validation. Attackers with valid credentials can exploit this flaw by sending crafted packets containing malicious commands to affected devices, leading to arbitrary command execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-03T05:56:30.541Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/command-execution-vulnerability-in-some-wireless-ap-products/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-16843",
    "datePublished": "2026-07-31T09:31:30.862Z",
    "dateReserved": "2026-07-24T03:06:45.941Z",
    "dateUpdated": "2026-08-03T05:56:30.541Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-61392 (GCVE-0-2026-61392)
Vulnerability from cvelistv5
Published
2026-07-22 11:03
Modified
2026-07-22 12:29
Summary
There is a information disclosure vulnerability in some Hikvision cameras, allowing unauthenticated attackers to obtain partial information from the device’s memory.
Impacted products
Vendor Product Version
Hikvision DS-2CD Series Version: https://www.hikvision.com/en/support/download/firmware/security-firmware-download/
Create a notification for this product.
   Hikvision DS-2DE Series Version: https://www.hikvision.com/en/support/download/firmware/security-firmware-download/
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-61392",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-22T12:27:07.318701Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-200",
                "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-22T12:29:21.886Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-2CD Series",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/en/support/download/firmware/security-firmware-download/",
              "versionType": "link"
            }
          ]
        },
        {
          "product": "DS-2DE Series",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/en/support/download/firmware/security-firmware-download/",
              "versionType": "link"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Daniel Kaye of Inversus Labs"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a information disclosure vulnerability in some Hikvision cameras, allowing unauthenticated attackers to obtain partial information from the device\u2019s memory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-22T11:03:11.533Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikvision-cameras/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-61392",
    "datePublished": "2026-07-22T11:03:11.533Z",
    "dateReserved": "2026-07-09T05:51:16.531Z",
    "dateUpdated": "2026-07-22T12:29:21.886Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-61391 (GCVE-0-2026-61391)
Vulnerability from cvelistv5
Published
2026-07-22 11:02
Modified
2026-07-22 12:31
Summary
There is a stack-based buffer overflow vulnerability in some Hikvision cameras, which may allow authenticated attackers to cause device malfunction by sending specially crafted packets.
Impacted products
Vendor Product Version
Hikvision DS-2CD Series Version: https://www.hikvision.com/en/support/download/firmware/security-firmware-download/
Create a notification for this product.
   Hikvision DS-2DE Series Version: https://www.hikvision.com/en/support/download/firmware/security-firmware-download/
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-61391",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-22T12:30:41.711706Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-22T12:31:18.388Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-2CD Series",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/en/support/download/firmware/security-firmware-download/",
              "versionType": "link"
            }
          ]
        },
        {
          "product": "DS-2DE Series",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/en/support/download/firmware/security-firmware-download/",
              "versionType": "link"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Daniel Kaye of Inversus Labs"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a stack-based buffer overflow vulnerability in some Hikvision cameras, which may allow authenticated attackers to cause device malfunction by sending specially crafted packets."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-22T11:02:27.332Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikvision-cameras/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-61391",
    "datePublished": "2026-07-22T11:02:27.332Z",
    "dateReserved": "2026-07-09T05:51:16.531Z",
    "dateUpdated": "2026-07-22T12:31:18.388Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-61390 (GCVE-0-2026-61390)
Vulnerability from cvelistv5
Published
2026-07-22 11:02
Modified
2026-07-22 12:34
Summary
There is a heap buffer overflow vulnerability in some Hikvision cameras, which may allow unauthenticated attackers to cause device malfunction by sending specially crafted packets.
Impacted products
Vendor Product Version
Hikvision DS-2CD Series Version: https://www.hikvision.com/en/support/download/firmware/security-firmware-download/
Create a notification for this product.
   Hikvision DS-2DE Series Version: https://www.hikvision.com/en/support/download/firmware/security-firmware-download/
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-61390",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-22T12:32:13.576488Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-122",
                "description": "CWE-122 Heap-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-22T12:34:30.832Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-2CD Series",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/en/support/download/firmware/security-firmware-download/",
              "versionType": "link"
            }
          ]
        },
        {
          "product": "DS-2DE Series",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/en/support/download/firmware/security-firmware-download/",
              "versionType": "link"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Daniel Kaye of Inversus Labs"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a heap buffer overflow vulnerability in some Hikvision cameras, which may allow unauthenticated attackers to cause device malfunction by sending specially crafted packets."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-22T11:02:00.804Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikvision-cameras/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-61390",
    "datePublished": "2026-07-22T11:02:00.804Z",
    "dateReserved": "2026-07-09T05:51:16.530Z",
    "dateUpdated": "2026-07-22T12:34:30.832Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-57600 (GCVE-0-2026-57600)
Vulnerability from cvelistv5
Published
2026-07-22 11:01
Modified
2026-07-22 12:35
Summary
Insufficient validation of input parameters in the firmware of some Hikvision cameras allows unauthenticated attackers to retrieve partial sensitive data.
Impacted products
Vendor Product Version
Hikvision DS-2CD Series Version: https://www.hikvision.com/en/support/download/firmware/security-firmware-download/
Create a notification for this product.
   Hikvision DS-2DE Series Version: https://www.hikvision.com/en/support/download/firmware/security-firmware-download/
Create a notification for this product.
   Hikvision DS-2DP Series Version: https://www.hikvision.com/en/support/download/firmware/security-firmware-download/
Create a notification for this product.
   Hikvision DS-2TD Series Version: https://www.hikvision.com/en/support/download/firmware/security-firmware-download/
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-57600",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-22T12:34:49.066951Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-22T12:35:10.527Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-2CD Series",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/en/support/download/firmware/security-firmware-download/",
              "versionType": "link"
            }
          ]
        },
        {
          "product": "DS-2DE Series",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/en/support/download/firmware/security-firmware-download/",
              "versionType": "link"
            }
          ]
        },
        {
          "product": "DS-2DP Series",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/en/support/download/firmware/security-firmware-download/",
              "versionType": "link"
            }
          ]
        },
        {
          "product": "DS-2TD Series",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/en/support/download/firmware/security-firmware-download/",
              "versionType": "link"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Bitdefender IoT Security Team"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Insufficient validation of input parameters in the firmware of some Hikvision cameras allows unauthenticated attackers to retrieve partial sensitive data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-22T11:01:36.269Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikvision-cameras/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-57600",
    "datePublished": "2026-07-22T11:01:36.269Z",
    "dateReserved": "2026-06-25T02:07:05.126Z",
    "dateUpdated": "2026-07-22T12:35:10.527Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-57599 (GCVE-0-2026-57599)
Vulnerability from cvelistv5
Published
2026-07-22 11:00
Modified
2026-07-22 12:44
Summary
There is a privilege escalation vulnerability in some Hikvision cameras. Due to incorrect permission allocation in the device program, attackers can escalate privileges and gain full control of the device after authenticating via SSH.
Impacted products
Vendor Product Version
Hikvision DS-2CD Series Version: https://www.hikvision.com/en/support/download/firmware/security-firmware-download/
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-57599",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-22T12:44:40.877849Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-269",
                "description": "CWE-269 Improper Privilege Management",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-22T12:44:49.458Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-2CD Series",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.hikvision.com/en/support/download/firmware/security-firmware-download/",
              "versionType": "link"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Joffrey Czarny"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a privilege escalation vulnerability in some Hikvision cameras. Due to incorrect permission allocation in the device program, attackers can escalate privileges and gain full control of the device after authenticating via SSH."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-22T11:00:49.219Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikvision-cameras/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-57599",
    "datePublished": "2026-07-22T11:00:49.219Z",
    "dateReserved": "2026-06-25T02:07:05.126Z",
    "dateUpdated": "2026-07-22T12:44:49.458Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-32684 (GCVE-0-2026-32684)
Vulnerability from cvelistv5
Published
2026-05-12 10:51
Modified
2026-06-02 16:04
Summary
The application does not impose strict enough restrictions on directory access permissions, posing a risk that other malicious applications could obtain sensitive information.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-32684",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-12T12:06:07.612844Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-732",
                "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-02T16:04:38.256Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Hik-Connect APP",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V6.10.x"
            },
            {
              "status": "unaffected",
              "version": "V6.12.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Yi\u011fithan Y\u00fcceda\u011f"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The application does not impose strict enough restrictions on directory access permissions, posing a risk that other malicious applications could obtain sensitive information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 2.9,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-12T10:51:08.585Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://pinfo.hikvision.com/hkwsen/unzip/20260511114030_14652_doc/GUID-A47A8570-631E-4F62-BCEE-37E9F2983DD7.html"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-32684",
    "datePublished": "2026-05-12T10:51:08.585Z",
    "dateReserved": "2026-03-13T07:45:08.745Z",
    "dateUpdated": "2026-06-02T16:04:38.256Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-3828 (GCVE-0-2026-3828)
Vulnerability from cvelistv5
Published
2026-05-09 08:27
Modified
2026-05-11 15:22
Summary
Some Hikvision switch products (discontinued since December 2023) are vulnerable to authenticated remote command execution due to insufficient input validation. Attackers with valid credentials can exploit this flaw by sending crafted packets containing malicious commands to affected devices, leading to arbitrary command execution.
Impacted products
Vendor Product Version
Hikvision DS-3E1310P-SI Version: Versions below V1.2.4_210623 (including V1.2.4_210623)
Create a notification for this product.
   Hikvision DS-3E1318P-SI Version: Versions below V1.2.0_210823 (including V1.2.0_210823)
Create a notification for this product.
   Hikvision DS-3E1326P-SI Version: Versions below V1.2.0_210823 (including V1.2.0_210823)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-3828",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-11T15:22:31.962279Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-78",
                "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-11T15:22:55.314Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-3E1310P-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V1.2.4_210623 (including V1.2.4_210623)"
            }
          ]
        },
        {
          "product": "DS-3E1318P-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V1.2.0_210823 (including V1.2.0_210823)"
            }
          ]
        },
        {
          "product": "DS-3E1326P-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V1.2.0_210823 (including V1.2.0_210823)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Thiago Torres (torresm)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Some Hikvision switch products (discontinued since December 2023) are vulnerable to authenticated remote command execution due to insufficient input validation. Attackers with valid credentials can exploit this flaw by sending crafted packets containing malicious commands to affected devices, leading to arbitrary command execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-09T08:27:55.964Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/command-execution-vulnerability-in-some-hikvision-switch-product/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-3828",
    "datePublished": "2026-05-09T08:27:55.964Z",
    "dateReserved": "2026-03-09T09:20:38.428Z",
    "dateUpdated": "2026-05-11T15:22:55.314Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-1749 (GCVE-0-2026-1749)
Vulnerability from cvelistv5
Published
2026-05-09 08:27
Modified
2026-05-11 15:21
Summary
There is an Access Control Vulnerability in some HikCentral Professional versions. This could allow an unauthenticated user to obtain the admin permission.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-1749",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-11T15:21:36.019611Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-11T15:21:55.304Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HikCentral Professional",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V2.4.0~V3.0.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Ayoub ELMOKHTAR from the Offensive Security Team (Noon)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is an Access Control Vulnerability in some HikCentral Professional versions. This could allow an unauthenticated user to obtain the admin permission."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-09T08:27:15.849Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerability-in-hikcentral-professional/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-1749",
    "datePublished": "2026-05-09T08:27:15.849Z",
    "dateReserved": "2026-02-02T02:00:26.271Z",
    "dateUpdated": "2026-05-11T15:21:55.304Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-0709 (GCVE-0-2026-0709)
Vulnerability from cvelistv5
Published
2026-01-30 11:01
Modified
2026-02-27 14:49
Summary
Some Hikvision Wireless Access Points are vulnerable to authenticated command execution due to insufficient input validation. Attackers with valid credentials can exploit this flaw by sending crafted packets containing malicious commands to affected devices, leading to arbitrary command execution.
Impacted products
Vendor Product Version
Hikvision DS-3WAP521-SI Version: V1.1.6303 build250812 and earlier
Create a notification for this product.
   Hikvision DS-3WAP522-SI Version: V1.1.6303 build250812 and earlier
Create a notification for this product.
   Hikvision DS-3WAP621E-SI Version: V1.1.6303 build250812 and earlier
Create a notification for this product.
   Hikvision DS-3WAP622E-SI Version: V1.1.6303 build250812 and earlier
Create a notification for this product.
   Hikvision DS-3WAP623E-SI Version: V1.1.6303 build250812 and earlier
Create a notification for this product.
   Hikvision DS-3WAP622G-SI Version: V1.1.6303 build250812 and earlier
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-0709",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T12:13:24.741883Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-78",
                "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-27T14:49:22.572Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-3WAP521-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6303 build250812 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WAP522-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6303 build250812 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WAP621E-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6303 build250812 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WAP622E-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6303 build250812 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WAP623E-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6303 build250812 and earlier"
            }
          ]
        },
        {
          "product": "DS-3WAP622G-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.6303 build250812 and earlier"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "exzettabyte"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Some Hikvision Wireless Access Points are vulnerable to authenticated command execution due to insufficient input validation. Attackers with valid credentials can exploit this flaw by sending crafted packets containing malicious commands to affected devices, leading to arbitrary command execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-30T11:01:55.633Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/command-execution-vulnerability-in-some-hikvision-wireless-access-point-products/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-0709",
    "datePublished": "2026-01-30T11:01:55.633Z",
    "dateReserved": "2026-01-08T05:49:12.677Z",
    "dateUpdated": "2026-02-27T14:49:22.572Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-66177 (GCVE-0-2025-66177)
Vulnerability from cvelistv5
Published
2026-01-13 01:47
Modified
2026-07-09 06:22
Summary
There is a Buffer overflow Vulnerability in the device Search and Discovery feature of Hikvision NVR/DVR/CVR/IPC models. If exploited, an attacker on the same local area network (LAN) could cause the device to malfunction by sending specially crafted packets to an unpatched device.
Impacted products
Vendor Product Version
Hikvision DS-96xxxNI-Hx Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-96xxxNI-Ix Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-96xxNXI-Sx Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-96xxxNXI-Sx Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNXI-Mx/VPro Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-96xxNXI-Mx/VPro Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNI-Mx Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-77xxNI-Mx Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-96xxNXI-Mx Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-96xxxNXI-Mx Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-86xxxNXI-Mx Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNXI-Ix/S Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-77xxNXI-Ix/S Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-86xxNXI-Ix/S Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-96xxNXI-Ix/S Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNXI-Ix/VPro Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-77xxNXI-Ix/VPro Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNXI-Kx(/xP) including(D)、(E)、(B) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-77xxNXI-Kx(/xP) including(D)、(E)、(B) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNXI-Kx(/xP)/Vpro Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-77xxNXI-Kx(/xP)/Vpro Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNI-Qx(/xP) including(D)、(E) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-71xxNI-Q1(/xP)/M Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-71xxNI-Q1(/xP) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-710xNI-G1/(xP)/M Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-71xxNI-Q1(/xP) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-71xxNI-Q1(/xP)/M Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNI-Q1(/xP) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNI-Q2(/xP) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNXI-K1(/xP) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNXI-K2(/xP) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-77xxNXI-K4(/xP) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-86xxNXI-K8(/xP) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNXI-K1(/xP)/VPro Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-76xxNXI-K2(/xP)/VPro Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-77xxNXI-K4(/xP)/VPro Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-71xxHGHI-M1(/T) Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHGHI-M1(/T) Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-71xxHQHI-M1(/T) Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHQHI-M1(/T) Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHQHI-Mx/XT Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHUHI-Mx/XT Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHTHI-Mx/XT Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-90xxHUHI-M8/S(S) Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-73xxHUHI-M4/S(S) Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-81xxHUHI-M8/S(S) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-71xxHGHI-M1(/T) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-72xxHGHI-M1(/T) Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-ExxHGHI-xx Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-71xxHQHI-M1/S Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHQHI-M1/E Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-71xxHQHI-M1/T Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHQHI-M1/T Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHQHI-Mx/XT Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-73xxHQHI-M4/S Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-81xxHQHI-M8/S Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-90xxHQHI-M8/S Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-ExxHQHI-xx Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-71xxHUHI-M1/S Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHUHI-M1/E Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHUHI-M1/T Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHUHI-Mx/X Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHUHI-Mx/XT Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHUHI-Mx/PXT Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-73xxHUHI-M4/S Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-90xxHUHI-M8/S Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-ExxHUHI-xx Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-72xxHTHI-Mx/XT Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-A806xxSI Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-AT1000SI Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-96xxxNXI-Hx Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-96064NXI-I16 Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-96xxxNXI-Ix/AI Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-67xxNXI-Mx/X Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-76xxNXI-Mx/X Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-77xxNXI-Mx/X Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-96xxNXI-Mx/X Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-96xxxNXI-Mx/X Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-96xxxNXI-Hx/AI Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-96xxNXI-Mx/AI Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-67xxNXI-Mx/AI Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-67xxxNXI-Mx/AI Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-67xxNXI-S/T Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-67xxNXI-S Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-6704NXI/AI Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-67xxNXI-P1 Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-7608NXI-P2 Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-77xxNXI-P4 Version: Build date before 250807
Create a notification for this product.
   Hikvision iDS-96xxNXI-Px Version: Build date before 250807
Create a notification for this product.
   Hikvision DS-2CD1xxxG2 Version: Versions below V5.7.13_230822 (including V5.7.13_230822)
Create a notification for this product.
   Hikvision DS-2CD3xx1G2 Version: Versions below V5.7.13_230822 (including V5.7.13_230822)
Create a notification for this product.
   Hikvision HWI-xxxxHA Version: Versions below V5.7.13_230822 (including V5.7.13_230822)
Create a notification for this product.
   Hikvision IPC-xxxxHA Version: Versions below V5.7.13_230822 (including V5.7.13_230822)
Create a notification for this product.
   Hikvision DS-2CD2Dx5G1 Version: Versions below V5.7.210_240826 (including V5.7.210_240826)
Create a notification for this product.
   Hikvision DS-2CD64x5G1 Version: Versions below V5.7.210_240826 (including V5.7.210_240826)
Create a notification for this product.
   Hikvision DS-2CD29xxG0 Version: Versions below V5.7.21_240814 (including V5.7.21_240814)
Create a notification for this product.
   Hikvision DS-2XE6xxxG0 Version: Versions below V5.7.7build241203 (including V5.7.7build241203)
Create a notification for this product.
   Hikvision DS-2XC6xxxG0 Version: Versions below V5.7.7build241203 (including V5.7.7build241203)
Create a notification for this product.
   Hikvision DS-2CD1xxxG0(T) Version: Versions below V5.7.23_241015 (including V5.7.23_241015)
Create a notification for this product.
   Hikvision DS-2CD1xx1 Version: Versions below V5.7.23_241015 (including V5.7.23_241015)
Create a notification for this product.
   Hikvision DS-2CD3xx1G0 Version: Versions below V5.7.23_241015 (including V5.7.23_241015)
Create a notification for this product.
   Hikvision DS-2CD2xx1G0 Version: Versions below V5.7.23_241015 (including V5.7.23_241015)
Create a notification for this product.
   Hikvision IPC-xxxxH Version: Versions below V5.7.23_241015 (including V5.7.23_241015)
Create a notification for this product.
   Hikvision HWI-xxxH(C) Version: Versions below V5.7.23_241015 (including V5.7.23_241015)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-66177",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-13T14:26:06.385030Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-13T17:27:13.199Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-96xxxNI-Hx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-96xxxNI-Ix",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-96xxNXI-Sx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-96xxxNXI-Sx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNXI-Mx/VPro",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-96xxNXI-Mx/VPro",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNI-Mx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-77xxNI-Mx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-96xxNXI-Mx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-96xxxNXI-Mx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-86xxxNXI-Mx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNXI-Ix/S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-77xxNXI-Ix/S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-86xxNXI-Ix/S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-96xxNXI-Ix/S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNXI-Ix/VPro",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-77xxNXI-Ix/VPro",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNXI-Kx(/xP)  including(D)\u3001(E)\u3001(B)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-77xxNXI-Kx(/xP) including(D)\u3001(E)\u3001(B)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNXI-Kx(/xP)/Vpro",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-77xxNXI-Kx(/xP)/Vpro",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNI-Qx(/xP)   including(D)\u3001(E)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-71xxNI-Q1(/xP)/M",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-71xxNI-Q1(/xP)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-710xNI-G1/(xP)/M",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-71xxNI-Q1(/xP)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-71xxNI-Q1(/xP)/M",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNI-Q1(/xP)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNI-Q2(/xP)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNXI-K1(/xP)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNXI-K2(/xP)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-77xxNXI-K4(/xP)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-86xxNXI-K8(/xP)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNXI-K1(/xP)/VPro",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-76xxNXI-K2(/xP)/VPro",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-77xxNXI-K4(/xP)/VPro",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-71xxHGHI-M1(/T)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHGHI-M1(/T)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-71xxHQHI-M1(/T)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHQHI-M1(/T)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHQHI-Mx/XT",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHUHI-Mx/XT",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHTHI-Mx/XT",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-90xxHUHI-M8/S(S)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-73xxHUHI-M4/S(S)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-81xxHUHI-M8/S(S)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-71xxHGHI-M1(/T)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-72xxHGHI-M1(/T)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-ExxHGHI-xx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-71xxHQHI-M1/S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHQHI-M1/E",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-71xxHQHI-M1/T",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHQHI-M1/T",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHQHI-Mx/XT",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-73xxHQHI-M4/S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-81xxHQHI-M8/S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-90xxHQHI-M8/S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-ExxHQHI-xx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-71xxHUHI-M1/S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHUHI-M1/E",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHUHI-M1/T",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHUHI-Mx/X",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHUHI-Mx/XT",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHUHI-Mx/PXT",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-73xxHUHI-M4/S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-90xxHUHI-M8/S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-ExxHUHI-xx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-72xxHTHI-Mx/XT",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-A806xxSI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-AT1000SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-96xxxNXI-Hx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-96064NXI-I16",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-96xxxNXI-Ix/AI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-67xxNXI-Mx/X",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-76xxNXI-Mx/X",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-77xxNXI-Mx/X",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-96xxNXI-Mx/X",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-96xxxNXI-Mx/X",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-96xxxNXI-Hx/AI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-96xxNXI-Mx/AI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-67xxNXI-Mx/AI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-67xxxNXI-Mx/AI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-67xxNXI-S/T",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-67xxNXI-S",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-6704NXI/AI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-67xxNXI-P1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-7608NXI-P2",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-77xxNXI-P4",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "iDS-96xxNXI-Px",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Build date before 250807"
            }
          ]
        },
        {
          "product": "DS-2CD1xxxG2",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.13_230822 (including V5.7.13_230822)"
            }
          ]
        },
        {
          "product": "DS-2CD3xx1G2",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.13_230822 (including V5.7.13_230822)"
            }
          ]
        },
        {
          "product": "HWI-xxxxHA",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.13_230822 (including V5.7.13_230822)"
            }
          ]
        },
        {
          "product": "IPC-xxxxHA",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.13_230822 (including V5.7.13_230822)"
            }
          ]
        },
        {
          "product": "DS-2CD2Dx5G1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.210_240826 (including V5.7.210_240826)"
            }
          ]
        },
        {
          "product": "DS-2CD64x5G1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.210_240826 (including V5.7.210_240826)"
            }
          ]
        },
        {
          "product": "DS-2CD29xxG0",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.21_240814 (including V5.7.21_240814)"
            }
          ]
        },
        {
          "product": "DS-2XE6xxxG0",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.7build241203 (including V5.7.7build241203)"
            }
          ]
        },
        {
          "product": "DS-2XC6xxxG0",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.7build241203 (including V5.7.7build241203)"
            }
          ]
        },
        {
          "product": "DS-2CD1xxxG0(T)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.23_241015 (including V5.7.23_241015)"
            }
          ]
        },
        {
          "product": "DS-2CD1xx1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.23_241015 (including V5.7.23_241015)"
            }
          ]
        },
        {
          "product": "DS-2CD3xx1G0",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.23_241015 (including V5.7.23_241015)"
            }
          ]
        },
        {
          "product": "DS-2CD2xx1G0",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.23_241015 (including V5.7.23_241015)"
            }
          ]
        },
        {
          "product": "IPC-xxxxH",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.23_241015 (including V5.7.23_241015)"
            }
          ]
        },
        {
          "product": "HWI-xxxH(C)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V5.7.23_241015 (including V5.7.23_241015)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Angel Lozano Alcazar"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Pedro Guillen Nu\u00f1ez"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a Buffer overflow Vulnerability in the device Search and Discovery feature of Hikvision NVR/DVR/CVR/IPC models. If exploited, an attacker on the same local area network (LAN) could cause the device to malfunction by sending specially crafted packets to an unpatched device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-09T06:22:08.882Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/buffer-overflow-vulnerabilities-in-some-hikvision-products/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2025-66177",
    "datePublished": "2026-01-13T01:47:54.031Z",
    "dateReserved": "2025-11-24T08:59:35.903Z",
    "dateUpdated": "2026-07-09T06:22:08.882Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-66176 (GCVE-0-2025-66176)
Vulnerability from cvelistv5
Published
2026-01-13 01:47
Modified
2026-07-09 06:21
Summary
There is a Buffer overflow Vulnerability in the device Search and Discovery feature of Hikvision Access Control Products. If exploited, an attacker on the same local area network (LAN) could cause the device to malfunction by sending specially crafted packets to an unpatched device.
Impacted products
Vendor Product Version
Hikvision DS-K1T331 Version: Versions below V3.7.80
Create a notification for this product.
   Hikvision DS-K1T341A/K1T341B Version: Versions below V3.7.80
Create a notification for this product.
   Hikvision DS-K1T671/K5671 Version: Versions below V3.7.80
Create a notification for this product.
   Hikvision DS-K1T672 Version: Versions below V3.7.80
Create a notification for this product.
   Hikvision DS-K1T680 Version: Versions below V3.7.80
Create a notification for this product.
   Hikvision DS-K1T981 Version: Versions below V3.7.80
Create a notification for this product.
   Hikvision DS-K1T341C Version: Versions below V3.3.180
Create a notification for this product.
   Hikvision DS-K1T670/K1T673 Version: Versions below V4.48.0
Create a notification for this product.
   Hikvision DS-K1T8003 Version: Versions below V1.4.21
Create a notification for this product.
   Hikvision DS-K1T804A Version: Versions below V1.4.22
Create a notification for this product.
   Hikvision DS-K1T8003/8004 Version: Versions below V1.4.21
Create a notification for this product.
   Hikvision DS-K1T804A Version: Versions below V1.4.22
Create a notification for this product.
   Hikvision DS-K1T804B Version: Versions below V1.4.23
Create a notification for this product.
   Hikvision DS-K1T201A/K1T105A Version: Versions below V1.3.65
Create a notification for this product.
   Hikvision DS-K1T342/K1T343/K1T344/DS-K1T6QT-F72/F43 Version: Versions below V4.48.0
Create a notification for this product.
   Hikvision DS-K1T8005/DS-K1T808 Version: Versions below V3.25.40
Create a notification for this product.
   Hikvision DS-K1T320/DS-K1T321 Version: Versions below V3.9.40
Create a notification for this product.
   Hikvision DS-K1T323/DS-K1T510 Version: Versions below V4.23.41
Create a notification for this product.
   Hikvision DS-K5033 Version: Versions below V4.37.40
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-66176",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-13T14:32:35.447766Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-13T17:28:04.643Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2026-03-18T15:28:09.433Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2281"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-K1T331",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V3.7.80"
            }
          ]
        },
        {
          "product": "DS-K1T341A/K1T341B",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V3.7.80"
            }
          ]
        },
        {
          "product": "DS-K1T671/K5671",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V3.7.80"
            }
          ]
        },
        {
          "product": "DS-K1T672",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V3.7.80"
            }
          ]
        },
        {
          "product": "DS-K1T680",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V3.7.80"
            }
          ]
        },
        {
          "product": "DS-K1T981",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V3.7.80"
            }
          ]
        },
        {
          "product": "DS-K1T341C",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V3.3.180"
            }
          ]
        },
        {
          "product": "DS-K1T670/K1T673",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.48.0"
            }
          ]
        },
        {
          "product": "DS-K1T8003",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V1.4.21"
            }
          ]
        },
        {
          "product": "DS-K1T804A",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V1.4.22"
            }
          ]
        },
        {
          "product": "DS-K1T8003/8004",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V1.4.21"
            }
          ]
        },
        {
          "product": "DS-K1T804A",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V1.4.22"
            }
          ]
        },
        {
          "product": "DS-K1T804B",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V1.4.23"
            }
          ]
        },
        {
          "product": "DS-K1T201A/K1T105A",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V1.3.65"
            }
          ]
        },
        {
          "product": "DS-K1T342/K1T343/K1T344/DS-K1T6QT-F72/F43",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.48.0"
            }
          ]
        },
        {
          "product": "DS-K1T8005/DS-K1T808",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V3.25.40"
            }
          ]
        },
        {
          "product": "DS-K1T320/DS-K1T321",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V3.9.40"
            }
          ]
        },
        {
          "product": "DS-K1T323/DS-K1T510",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.23.41"
            }
          ]
        },
        {
          "product": "DS-K5033",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.37.40"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Matt Wiseman of Cisco Talos"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a Buffer overflow Vulnerability in the device Search and Discovery feature of Hikvision Access Control Products. If exploited, an attacker on the same local area network (LAN) could cause the device to malfunction by sending specially crafted packets to an unpatched device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-09T06:21:34.763Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/buffer-overflow-vulnerabilities-in-some-hikvision-products/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2025-66176",
    "datePublished": "2026-01-13T01:47:27.191Z",
    "dateReserved": "2025-11-24T08:59:35.903Z",
    "dateUpdated": "2026-07-09T06:21:34.763Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-66174 (GCVE-0-2025-66174)
Vulnerability from cvelistv5
Published
2025-12-19 06:39
Modified
2025-12-19 15:41
Summary
There is an improper authentication vulnerability in some Hikvision DVR products. Due to the improper implementation of authentication for the serial port, an attacker with physical access could exploit this vulnerability by connecting to the affected products and run a series of commands.
Impacted products
Vendor Product Version
Hikvision DS-7104HGHI-F1 Version: Versions below V4.30.122_201107 (including V4.30.122_201107)
Create a notification for this product.
   Hikvision DS-7204HGHI-F1 Version: Versions below V4.30.122_201107 (including V4.30.122_201107)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-66174",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-19T15:41:12.037984Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-287",
                "description": "CWE-287 Improper Authentication",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-19T15:41:32.976Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-7104HGHI-F1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.30.122_201107 (including V4.30.122_201107)"
            }
          ]
        },
        {
          "product": "DS-7204HGHI-F1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.30.122_201107 (including V4.30.122_201107)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aaron J Jose"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is an improper authentication vulnerability in some Hikvision DVR products. Due to the improper implementation of authentication for the serial port, an attacker with physical access could exploit this vulnerability by connecting to the affected products and run a series of commands."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-19T06:45:55.453Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/serial-port-privilege-escalation-vulnerabilities-in-some-hikvision-nvr-devices/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2025-66174",
    "datePublished": "2025-12-19T06:39:51.404Z",
    "dateReserved": "2025-11-24T08:59:35.903Z",
    "dateUpdated": "2025-12-19T15:41:32.976Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-66173 (GCVE-0-2025-66173)
Vulnerability from cvelistv5
Published
2025-12-19 06:39
Modified
2025-12-19 15:40
Summary
There is a privilege escalation vulnerability in some Hikvision DVR products. Due to the improper implementation of authentication for the serial port, an attacker with physical access could exploit this vulnerability by connecting to the affected products and gaining access to an unrestricted shell environment.
Impacted products
Vendor Product Version
Hikvision DS-7104HGHI-F1 Version: Versions below V4.30.122_201107 (including V4.30.122_201107)
Create a notification for this product.
   Hikvision DS-7204HGHI-F1 Version: Versions below V4.30.122_201107 (including V4.30.122_201107)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-66173",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-19T15:40:25.549400Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-269",
                "description": "CWE-269 Improper Privilege Management",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-19T15:40:52.217Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-7104HGHI-F1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.30.122_201107 (including V4.30.122_201107)"
            }
          ]
        },
        {
          "product": "DS-7204HGHI-F1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.30.122_201107 (including V4.30.122_201107)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aaron J Jose"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a privilege escalation vulnerability in some Hikvision DVR products. Due to the improper implementation of authentication for the serial port, an attacker with physical access could exploit this vulnerability by connecting to the affected products and gaining access to an unrestricted shell environment."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-19T06:45:40.814Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/serial-port-privilege-escalation-vulnerabilities-in-some-hikvision-nvr-devices/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2025-66173",
    "datePublished": "2025-12-19T06:39:38.504Z",
    "dateReserved": "2025-11-24T08:59:35.902Z",
    "dateUpdated": "2025-12-19T15:40:52.217Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-58274 (GCVE-0-2024-58274)
Vulnerability from cvelistv5
Published
2025-10-22 00:00
Modified
2025-10-22 13:55
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
Hikvision CSMP (Comprehensive Security Management Platform) iSecure Center through 2024-08-01 allows execution of a command within $( ) in /center/api/installation/detection JSON data, as exploited in the wild in 2024 and 2025.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-58274",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-22T13:55:11.718588Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-22T13:55:16.083Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://xz.aliyun.com/news/14639"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "CSMP iSecure Center",
          "vendor": "Hikvision",
          "versions": [
            {
              "lessThanOrEqual": "2024-08-01",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Hikvision CSMP (Comprehensive Security Management Platform) iSecure Center through 2024-08-01 allows execution of a command within $( ) in /center/api/installation/detection JSON data, as exploited in the wild in 2024 and 2025."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-22T03:45:04.855Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/ahisec/nuclei-tps/blob/main/http/vulnerabilities/hikvision/hikvision-csmp-installation-rce.yaml"
        },
        {
          "url": "https://forum.butian.net/article/498"
        },
        {
          "url": "https://xz.aliyun.com/news/14639"
        }
      ],
      "x_generator": {
        "engine": "enrichogram 0.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-58274",
    "datePublished": "2025-10-22T00:00:00.000Z",
    "dateReserved": "2025-10-22T00:00:00.000Z",
    "dateUpdated": "2025-10-22T13:55:16.083Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-53691 (GCVE-0-2023-53691)
Vulnerability from cvelistv5
Published
2025-10-22 00:00
Modified
2025-10-22 13:56
CWE
  • CWE-24 - Path Traversal: '../filedir'
Summary
Hikvision CSMP (Comprehensive Security Management Platform) iSecure Center through 2023-06-25 allows file upload via /center/api/files directory traversal, as exploited in the wild in 2024 and 2025.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-53691",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-22T13:56:40.313239Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-22T13:56:44.179Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://zhuanlan.zhihu.com/p/639514473"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "CSMP iSecure Center",
          "vendor": "Hikvision",
          "versions": [
            {
              "lessThanOrEqual": "2023-06-25",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Hikvision CSMP (Comprehensive Security Management Platform) iSecure Center through 2023-06-25 allows file upload via /center/api/files directory traversal, as exploited in the wild in 2024 and 2025."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-24",
              "description": "CWE-24 Path Traversal: \u0027../filedir\u0027",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-22T03:42:57.265Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://zhuanlan.zhihu.com/p/639514473"
        }
      ],
      "x_generator": {
        "engine": "enrichogram 0.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-53691",
    "datePublished": "2025-10-22T00:00:00.000Z",
    "dateReserved": "2025-10-22T00:00:00.000Z",
    "dateUpdated": "2025-10-22T13:56:44.179Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28815 (GCVE-0-2023-28815)
Vulnerability from cvelistv5
Published
2025-10-17 11:07
Modified
2025-10-17 12:10
Severity ?
Summary
Some versions of Hikvision's iSecure Center Product contain insufficient parameter validation, resulting in a command injection vulnerability. Attackers may exploit this to gain platform privileges and execute arbitrary commands on the system.iSecure Center is software released for China's domestic market only, with no overseas release.
Impacted products
Vendor Product Version
Hikvision iSecure Center Version: V1.0.0 - V1.7.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28815",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-17T12:10:12.884691Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-141",
                "description": "CWE-141 Improper Neutralization of Parameter/Argument Delimiters",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-17T12:10:16.930Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "iSecure Center",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.0.0 - V1.7.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "hsrc"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Some versions of Hikvision\u0027s iSecure Center Product contain insufficient parameter validation, resulting in a command injection vulnerability. Attackers may exploit this to gain platform privileges and execute arbitrary commands on the system.iSecure Center is software released for China\u0027s domestic market only, with no overseas release."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-17T11:07:26.306Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/cn/support/CybersecurityCenter/SecurityNotices/2023-04/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2023-28815",
    "datePublished": "2025-10-17T11:07:26.306Z",
    "dateReserved": "2023-03-23T19:49:08.441Z",
    "dateUpdated": "2025-10-17T12:10:16.930Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28814 (GCVE-0-2023-28814)
Vulnerability from cvelistv5
Published
2025-10-17 11:07
Modified
2025-10-17 13:04
Severity ?
Summary
Some versions of Hikvision's iSecure Center Product have an improper file upload control vulnerability. Due to the improper verification of file to be uploaded, attackers may upload malicious files to the server. iSecure Center is software released for China's domestic market only, with no overseas release.
Impacted products
Vendor Product Version
Hikvision iSecure Center Version: V1.0.0 - V1.7.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28814",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-17T13:04:13.622732Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-434",
                "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-17T13:04:24.853Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "iSecure Center",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.0.0 - V1.7.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "hsrc"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Some versions of Hikvision\u0027s iSecure Center Product have an improper file upload control vulnerability. Due to the improper verification of file to be uploaded, attackers may upload malicious files to the server. iSecure Center is software released for China\u0027s domestic market only, with no overseas release."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-17T11:07:06.801Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/cn/support/CybersecurityCenter/SecurityNotices/2023-03/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2023-28814",
    "datePublished": "2025-10-17T11:07:06.801Z",
    "dateReserved": "2023-03-23T19:49:08.440Z",
    "dateUpdated": "2025-10-17T13:04:24.853Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-39247 (GCVE-0-2025-39247)
Vulnerability from cvelistv5
Published
2025-08-29 01:40
Modified
2025-08-29 13:32
Summary
There is an Access Control Vulnerability in some HikCentral Professional versions. This could allow an unauthenticated user to obtain the admin permission.
Impacted products
Vendor Product Version
Hikvision HikCentral Professional Version: Versions between V2.3.1 and V2.6.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-39247",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-29T13:32:15.480416Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-29T13:32:18.140Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HikCentral Professional",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions between V2.3.1 and V2.6.2"
            }
          ]
        },
        {
          "product": "HikCentral Professional",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Version V3.0.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dr. Matthias Lutter"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is an Access Control Vulnerability in some HikCentral Professional versions. This could allow an unauthenticated user to obtain the admin permission."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-29T01:40:31.553Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikcentral-products/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2025-39247",
    "datePublished": "2025-08-29T01:40:31.553Z",
    "dateReserved": "2025-04-16T05:37:51.248Z",
    "dateUpdated": "2025-08-29T13:32:18.140Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-39246 (GCVE-0-2025-39246)
Vulnerability from cvelistv5
Published
2025-08-29 01:39
Modified
2025-08-29 13:32
Summary
There is an Unquoted Service Path Vulnerability in some HikCentral FocSign versions. This could allow an authenticated user to potentially enable escalation of privilege via local access.
Impacted products
Vendor Product Version
Hikvision HikCentral FocSign Version: Versions between V1.4.0 and V2.2.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-39246",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-29T13:32:36.393721Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-428",
                "description": "CWE-428 Unquoted Search Path or Element",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-29T13:32:53.476Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HikCentral FocSign",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions between V1.4.0 and V2.2.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Eduardo Bido"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is an Unquoted Service Path Vulnerability in some HikCentral FocSign versions. This could allow an authenticated user to potentially enable escalation of privilege via local access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-29T01:39:53.653Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikcentral-products/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2025-39246",
    "datePublished": "2025-08-29T01:39:53.653Z",
    "dateReserved": "2025-04-16T05:37:51.248Z",
    "dateUpdated": "2025-08-29T13:32:53.476Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-39245 (GCVE-0-2025-39245)
Vulnerability from cvelistv5
Published
2025-08-29 01:38
Modified
2025-08-29 13:33
Summary
There is a CSV Injection Vulnerability in some HikCentral Master Lite versions. This could allow an attacker to inject executable commands via malicious CSV data.
Impacted products
Vendor Product Version
Hikvision HikCentral Master Lite Version: Versions between V2.2.1 and V2.3.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-39245",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-29T13:33:21.122215Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-1236",
                "description": "CWE-1236 Improper Neutralization of Formula Elements in a CSV File",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-29T13:33:42.304Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HikCentral Master Lite",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions between V2.2.1 and V2.3.2"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Yousef Alfuhaid"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Nader Alharbi"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a CSV Injection Vulnerability in some HikCentral Master Lite versions. This could allow an attacker to inject executable commands via malicious CSV data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-29T01:38:46.917Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-some-hikcentral-products/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2025-39245",
    "datePublished": "2025-08-29T01:38:46.917Z",
    "dateReserved": "2025-04-16T05:37:51.248Z",
    "dateUpdated": "2025-08-29T13:33:42.304Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-34067 (GCVE-0-2025-34067)
Vulnerability from cvelistv5
Published
2025-07-02 13:44
Modified
2026-07-14 22:25
CWE
  • CWE-502 - Deserialization of Untrusted Data
Summary
An unauthenticated remote command execution vulnerability exists in the applyCT component of the Hikvision Integrated Security Management Platform due to the use of a vulnerable version of the Fastjson library. The endpoint /bic/ssoService/v1/applyCT deserializes untrusted user input, allowing an attacker to trigger Fastjson's auto-type feature to load arbitrary Java classes. By referencing a malicious class via an LDAP URL, an attacker can achieve remote code execution on the underlying system. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-34067",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-02T20:25:01.186074Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-02T20:25:16.191Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "/bic/ssoService/v1/applyCT HTTP endpoint"
          ],
          "product": "Integrated Security Management Platform",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:avaya:integrated_management:0:*:*:*:*:*:*:*",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn unauthenticated remote command execution vulnerability exists in the applyCT component of the Hikvision Integrated Security Management Platform due to the use of a vulnerable version of the Fastjson library. The endpoint /bic/ssoService/v1/applyCT deserializes untrusted user input, allowing an attacker to trigger Fastjson\u0027s auto-type feature to load arbitrary Java classes. By referencing a malicious class via an LDAP URL, an attacker can achieve remote code execution on the underlying system. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC.\u003c/p\u003e"
            }
          ],
          "value": "An unauthenticated remote command execution vulnerability exists in the applyCT component of the Hikvision Integrated Security Management Platform due to the use of a vulnerable version of the Fastjson library. The endpoint /bic/ssoService/v1/applyCT deserializes untrusted user input, allowing an attacker to trigger Fastjson\u0027s auto-type feature to load arbitrary Java classes. By referencing a malicious class via an LDAP URL, an attacker can achieve remote code execution on the underlying system. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-137",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-137 Parameter Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-502",
              "description": "CWE-502 Deserialization of Untrusted Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-14T22:25:42.705Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/PeiQi0/PeiQi-WIKI-Book/blob/main/docs/wiki/iot/HIKVISION/HIKVISION%20%E7%BB%BC%E5%90%88%E5%AE%89%E9%98%B2%E7%AE%A1%E7%90%86%E5%B9%B3%E5%8F%B0%20applyCT%20Fastjson%E8%BF%9C%E7%A8%8B%E5%91%BD%E4%BB%A4%E6%89%A7%E8%A1%8C%E6%BC%8F%E6%B4%9E.md"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://s4e.io/tools/hikvision-applyct-remote-code-execution"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vulncheck.com/advisories/hikvision-ismp-rce-applyct"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "tags": [
        "x_known-exploited-vulnerability"
      ],
      "title": "Hikvision Integrated Security Management Platform Remote Command Execution via applyCT Fastjson",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2025-34067",
    "datePublished": "2025-07-02T13:44:21.664Z",
    "dateReserved": "2025-04-15T19:15:22.549Z",
    "dateUpdated": "2026-07-14T22:25:42.705Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-39240 (GCVE-0-2025-39240)
Vulnerability from cvelistv5
Published
2025-06-13 07:10
Modified
2025-06-17 17:24
Summary
Some Hikvision Wireless Access Point are vulnerable to authenticated remote command execution due to insufficient input validation. Attackers with valid credentials can exploit this flaw by sending crafted packets containing malicious commands to affected devices, leading to arbitrary command execution.
Impacted products
Vendor Product Version
Hikvision DS-3WAP622G-SI Version: V1.1.5402 build241014(E2254P02)and the versions prior to it
Create a notification for this product.
   Hikvision DS-3WAP623E-SI Version: V1.1.5400 build240814(E2254)and the versions prior to it
Create a notification for this product.
   Hikvision DS-3WAP521-SI Version: V1.1.5400 build240814(E2254)and the versions prior to it
Create a notification for this product.
   Hikvision DS-3WAP522-SI Version: V1.1.5402 build241014(E2254P02)and the versions prior to it
Create a notification for this product.
   Hikvision DS-3WAP621E-SI Version: V1.1.5400 build240814(E2254)and the versions prior to it
Create a notification for this product.
   Hikvision DS-3WAP622E-SI Version: V1.1.5402 build241014(E2254P02)and the versions prior to it
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-39240",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-13T15:15:35.438694Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-78",
                "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-17T17:24:32.221Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-3WAP622G-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.5402 build241014\uff08E2254P02\uff09and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-3WAP623E-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.5400 build240814\uff08E2254\uff09and the versions prior to it"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "DS-3WAP521-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.5400 build240814\uff08E2254\uff09and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-3WAP522-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.5402 build241014\uff08E2254P02\uff09and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-3WAP621E-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.5400 build240814\uff08E2254\uff09and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-3WAP622E-SI",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V1.1.5402 build241014\uff08E2254P02\uff09and the versions prior to it"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "exzettabyte"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Some Hikvision Wireless Access Point are vulnerable to authenticated remote command execution due to insufficient input validation. Attackers with valid credentials can exploit this flaw by sending crafted packets containing malicious commands to affected devices, leading to arbitrary command execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-13T07:10:39.734Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/remote-command-execution-vulnerability-in-some-hikvision-wireless-access-point/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2025-39240",
    "datePublished": "2025-06-13T07:10:39.734Z",
    "dateReserved": "2025-04-16T05:37:51.246Z",
    "dateUpdated": "2025-06-17T17:24:32.221Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-47486 (GCVE-0-2024-47486)
Vulnerability from cvelistv5
Published
2024-10-18 08:33
Modified
2024-11-21 14:54
Summary
There is an XSS vulnerability in some HikCentral Master Lite versions. If exploited, an attacker could inject scripts into certain pages by building malicious data.
Impacted products
Vendor Product Version
Hikvision HikCentral Master Lite Version: Versions below V2.2.1 (including V2.2.1)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-47486",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-18T14:36:23.738242Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T14:54:17.043Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HikCentral Master Lite",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V2.2.1 (including V2.2.1)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Yousef Alfuhaid"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is an XSS vulnerability in some HikCentral Master Lite versions. If exploited, an attacker could inject scripts into certain pages by building malicious data."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 2.1,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-18T08:33:07.095Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-hikcentral-product-series/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2024-47486",
    "datePublished": "2024-10-18T08:33:07.095Z",
    "dateReserved": "2024-09-25T06:22:37.960Z",
    "dateUpdated": "2024-11-21T14:54:17.043Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-47487 (GCVE-0-2024-47487)
Vulnerability from cvelistv5
Published
2024-10-18 08:32
Modified
2025-03-19 17:46
Summary
There is a SQL injection vulnerability in some HikCentral Professional versions. This could allow an authenticated user to execute arbitrary SQL queries.
Impacted products
Vendor Product Version
Hikvision HikCentral Professional Version: Versions between V2.0.0 and V2.6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-47487",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-18T16:55:23.630917Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-89",
                "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-19T17:46:20.453Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HikCentral Professional",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions between V2.0.0 and V2.6.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Manh Doan Duc"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a SQL injection vulnerability in some HikCentral Professional versions. This could allow an authenticated user to execute arbitrary SQL queries."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:L/SC:L/SI:L/SA:L",
            "version": "4.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-18T08:32:45.182Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-hikcentral-product-series/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2024-47487",
    "datePublished": "2024-10-18T08:32:45.182Z",
    "dateReserved": "2024-09-25T06:22:37.961Z",
    "dateUpdated": "2025-03-19T17:46:20.453Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-47485 (GCVE-0-2024-47485)
Vulnerability from cvelistv5
Published
2024-10-18 08:29
Modified
2025-03-13 15:44
Summary
There is a CSV injection vulnerability in some HikCentral Master Lite versions. If exploited, an attacker could build malicious data to generate executable commands in the CSV file.
Impacted products
Vendor Product Version
Hikvision HikCentral Master Lite Version: Versions between V2.0.0 and V2.2.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:hikvision:hikcentral_master_lite:2.0.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "hikcentral_master_lite",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "2.2.1",
                "status": "affected",
                "version": "2.0.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-47485",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-18T13:39:24.820376Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-1236",
                "description": "CWE-1236 Improper Neutralization of Formula Elements in a CSV File",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-13T15:44:47.391Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HikCentral Master Lite",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions between V2.0.0 and V2.2.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Yousef Alfuhaid"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a CSV injection vulnerability in some HikCentral Master Lite versions. If exploited, an attacker could build malicious data to generate executable commands in the CSV file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H",
            "version": "4.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-18T08:29:38.392Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-hikcentral-product-series/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2024-47485",
    "datePublished": "2024-10-18T08:29:38.392Z",
    "dateReserved": "2024-09-25T06:22:37.960Z",
    "dateUpdated": "2025-03-13T15:44:47.391Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29949 (GCVE-0-2024-29949)
Vulnerability from cvelistv5
Published
2024-04-02 11:07
Modified
2024-08-27 14:53
Summary
There is a command injection vulnerability in some Hikvision NVRs. This could allow an authenticated user with administrative rights to execute arbitrary commands.
Impacted products
Vendor Product Version
Hikvision DS-7604NI-K1 / 4P(B) Version: V4.30.096build221220 and the versions prior to it
Create a notification for this product.
   Hikvision DS-76xxNI-Mx Version: Versions after V5.00.000 (including V5.00.000) and before V5.02.006(not including V5.02.006)
Create a notification for this product.
   Hikvision DS-77xxNI-Mx Version: Versions after V5.00.000 (including V5.00.000) and before V5.02.006(not including V5.02.006)
Create a notification for this product.
   Hikvision DS-96xxxNI-Mxx Version: Versions after V5.00.000 (including V5.00.000) and before V5.02.006(not including V5.02.006)
Create a notification for this product.
   Hikvision DS-76xxNXI-Ix Version: Versions after V5.00.000 (including V5.00.000) and before V5.02.006(not including V5.02.006)
Create a notification for this product.
   Hikvision DS-77xxNXI-Ix Version: Versions after V5.00.000 (including V5.00.000) and before V5.02.006(not including V5.02.006)
Create a notification for this product.
   Hikvision DS-86xxNXI-Ix Version: Versions after V5.00.000 (including V5.00.000) and before V5.02.006(not including V5.02.006)
Create a notification for this product.
   Hikvision DS-96xxNXI-Ix Version: Versions after V5.00.000 (including V5.00.000) and before V5.02.006(not including V5.02.006)
Create a notification for this product.
   Hikvision iDS-76xxNXI-Mx Version: Versions after V5.00.000 (including V5.00.000) and before V5.02.006(not including V5.02.006)
Create a notification for this product.
   Hikvision iDS-77xxNXI-Mx Version: Versions after V5.00.000 (including V5.00.000) and before V5.02.006(not including V5.02.006)
Create a notification for this product.
   Hikvision iDS-96xxxMXI-Mxx Version: Versions after V5.00.000 (including V5.00.000) and before V5.02.006(not including V5.02.006)
Create a notification for this product.
   Hikvision DS-7604NI-M1/4P Version: Versions after V5.00.000 (including V5.00.000) and before V5.01.070(not including V5.01.070)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.591Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-hikvision-nvr-devices/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ds-7604ni-k1\\/4p\\(b\\):*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ds-7604ni-k1\\/4p\\(b\\)",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThanOrEqual": "V4.30.096build221220",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ds-76xxni-mx:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ds-76xxni-mx",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "V5.02.006",
                "status": "affected",
                "version": "V5.00.000",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ds-77xxni-mx:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ds-77xxni-mx",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "5.02.006",
                "status": "affected",
                "version": "5.00.000",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ds-96xxxni-mxx:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ds-96xxxni-mxx",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "5.02.006",
                "status": "affected",
                "version": "5.00.000",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ds-76xxnxi-lx:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ds-76xxnxi-lx",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "5.02.006",
                "status": "affected",
                "version": "5.00.000",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ds-77xxnxi-lx:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ds-77xxnxi-lx",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "5.02.006",
                "status": "affected",
                "version": "5.00.000",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ds-86xxnxi-lx:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ds-86xxnxi-lx",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "5.02.006",
                "status": "affected",
                "version": "5.00.000",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ds-96xxnxi-lx:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ds-96xxnxi-lx",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "5.02.006",
                "status": "affected",
                "version": "5.00.000",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ids-76xxnxi-mx:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ids-76xxnxi-mx",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "5.02.006",
                "status": "affected",
                "version": "5.00.000",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ids-77xxnxi-mx:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ids-77xxnxi-mx",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "5.02.006",
                "status": "affected",
                "version": "5.00.000",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ids-96xxxmxi-mxx:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ids-96xxxmxi-mxx",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "5.02.006",
                "status": "affected",
                "version": "5.00.000",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:hikvision:ds-7604ni-m1\\/4p:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ds-7604ni-m1\\/4p",
            "vendor": "hikvision",
            "versions": [
              {
                "lessThan": "5.01.070",
                "status": "affected",
                "version": "5.00.000",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29949",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-02T17:55:48.331613Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-27T14:53:55.067Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-7604NI-K1 / 4P(B)",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "V4.30.096build221220 and the versions prior to it"
            }
          ]
        },
        {
          "product": "DS-76xxNI-Mx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions after V5.00.000 (including V5.00.000) and before V5.02.006\uff08not including V5.02.006\uff09"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "DS-77xxNI-Mx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions after V5.00.000 (including V5.00.000) and before V5.02.006\uff08not including V5.02.006\uff09"
            }
          ]
        },
        {
          "product": "DS-96xxxNI-Mxx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions after V5.00.000 (including V5.00.000) and before V5.02.006\uff08not including V5.02.006\uff09"
            }
          ]
        },
        {
          "product": "DS-76xxNXI-Ix",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions after V5.00.000 (including V5.00.000) and before V5.02.006\uff08not including V5.02.006\uff09"
            }
          ]
        },
        {
          "product": "DS-77xxNXI-Ix",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions after V5.00.000 (including V5.00.000) and before V5.02.006\uff08not including V5.02.006\uff09"
            }
          ]
        },
        {
          "product": "DS-86xxNXI-Ix",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions after V5.00.000 (including V5.00.000) and before V5.02.006\uff08not including V5.02.006\uff09"
            }
          ]
        },
        {
          "product": "DS-96xxNXI-Ix",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions after V5.00.000 (including V5.00.000) and before V5.02.006\uff08not including V5.02.006\uff09"
            }
          ]
        },
        {
          "product": "iDS-76xxNXI-Mx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions after V5.00.000 (including V5.00.000) and before V5.02.006\uff08not including V5.02.006\uff09"
            }
          ]
        },
        {
          "product": "iDS-77xxNXI-Mx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions after V5.00.000 (including V5.00.000) and before V5.02.006\uff08not including V5.02.006\uff09"
            }
          ]
        },
        {
          "product": "iDS-96xxxMXI-Mxx",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions after V5.00.000 (including V5.00.000) and before V5.02.006\uff08not including V5.02.006\uff09"
            }
          ]
        },
        {
          "product": "DS-7604NI-M1/4P",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions after V5.00.000 (including V5.00.000) and before V5.01.070\uff08not including V5.01.070\uff09"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "KITRI BoB 12th"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a command injection vulnerability in some Hikvision NVRs. This could allow an authenticated user with administrative rights to execute arbitrary commands."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-02T11:07:41.449Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-hikvision-nvr-devices/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2024-29949",
    "datePublished": "2024-04-02T11:07:41.449Z",
    "dateReserved": "2024-03-22T02:34:04.957Z",
    "dateUpdated": "2024-08-27T14:53:55.067Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}