Search

Find a vulnerability

Search criteria

    15 vulnerabilities found for mypro by myscada

    CVE-2025-35941 (GCVE-0-2025-35941)

    Vulnerability from cvelistv5 – Published: 2025-06-11 13:15 – Updated: 2025-06-11 13:53
    VLAI
    Title
    mySCADA PRO Manager Password Disclosure
    Summary
    A password is exposed locally.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-11 13:52 UTC
    CWE
    • CWE-522 - Insufficiently Protected Credentials
    Assigner
    tenable CNA
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: 1.3 , ≤ 1.4 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-35941",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-11T13:52:32.539291Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-522",
                    "description": "CWE-522 Insufficiently Protected Credentials",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-11T13:53:40.299Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThanOrEqual": "1.4",
                  "status": "affected",
                  "version": "1.3",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: transparent;\"\u003eA password is exposed locally.\u003c/span\u003e\u003cbr\u003e"
                }
              ],
              "value": "A password is exposed locally."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-11T13:15:50.588Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "url": "https://www.tenable.com/security/research/tra-2025-18"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "mySCADA PRO Manager Password Disclosure",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2025-35941",
        "datePublished": "2025-06-11T13:15:50.588Z",
        "dateReserved": "2025-04-15T21:07:39.882Z",
        "dateUpdated": "2025-06-11T13:53:40.299Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-4708 (GCVE-0-2024-4708)

    Vulnerability from cvelistv5 – Published: 2024-07-02 23:06 – Updated: 2024-08-01 20:47
    VLAI
    Title
    mySCADA myPRO Use of Hard-coded Password
    Summary
    mySCADA myPRO uses a hard-coded password which could allow an attacker to remotely execute code on the affected device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-05 20:10 UTC
    CWE
    • CWE-259 - Use of Hard-coded Password
    Assigner
    icscert CNA
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: 0 , < 8.31.0 (custom)
    Create a notification for this product.
    myscada mypro Affected: 0 , < 8.31.0 (custom)
        cpe:2.3:a:myscada:mypro:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-07-02 16:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:myscada:mypro:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "mypro",
                "vendor": "myscada",
                "versions": [
                  {
                    "lessThan": "8.31.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-4708",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-05T20:10:12.733058Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-05T21:23:04.236Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:47:41.657Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-02"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.myscada.org/mypro/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThan": "8.31.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Nassim Asrir working with Trend Micro Zero Day Initiative reported this vulnerability to CISA."
            }
          ],
          "datePublic": "2024-07-02T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "mySCADA myPRO \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003euses a hard-coded password which could allow an attacker to remotely execute code on the affected device.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "mySCADA myPRO \n\nuses a hard-coded password which could allow an attacker to remotely execute code on the affected device."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-259",
                  "description": "CWE-259 Use of Hard-coded Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-23T20:56:09.695Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-02"
            },
            {
              "url": "https://www.myscada.org/mypro/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003emySCADA recommends updating myPRO to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.myscada.org/mypro/\"\u003ev8.31.0\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "mySCADA recommends updating myPRO to  v8.31.0 https://www.myscada.org/mypro/ ."
            }
          ],
          "source": {
            "advisory": "ICSA-24-184-02",
            "discovery": "EXTERNAL"
          },
          "title": "mySCADA myPRO Use of Hard-coded Password",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-4708",
        "datePublished": "2024-07-02T23:06:21.045Z",
        "dateReserved": "2024-05-09T20:45:17.755Z",
        "dateUpdated": "2024-08-01T20:47:41.657Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-33013 (GCVE-0-2021-33013)

    Vulnerability from cvelistv5 – Published: 2022-05-13 15:19 – Updated: 2025-04-16 16:21
    VLAI
    Title
    mySCADA myPRO Improper Access Control
    Summary
    mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive system information.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 15:55 UTC
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: unspecified , < 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-08-05 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:42:19.054Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.myscada.org/version-8-20-0-released-security-update"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-33013",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:55:52.885313Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:21:39.950Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThan": "8.20.0",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2021-08-05T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive system information."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-13T15:19:35.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.myscada.org/version-8-20-0-released-security-update"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users apply update v8.20.0 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "mySCADA myPRO Improper Access Control",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-08-05T21:32:00.000Z",
              "ID": "CVE-2021-33013",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO Improper Access Control"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive system information."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-284: Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
                },
                {
                  "name": "https://www.myscada.org/version-8-20-0-released-security-update",
                  "refsource": "CONFIRM",
                  "url": "https://www.myscada.org/version-8-20-0-released-security-update"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users apply update v8.20.0 or later."
              }
            ],
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-33013",
        "datePublished": "2022-05-13T15:19:35.805Z",
        "dateReserved": "2021-05-13T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:21:39.950Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-33009 (GCVE-0-2021-33009)

    Vulnerability from cvelistv5 – Published: 2022-05-13 15:19 – Updated: 2025-04-16 16:21
    VLAI
    Title
    mySCADA myPRO Unrestricted Upload of File with Dangerous Type
    Summary
    mySCADA myPRO versions prior to 8.20.0 allows an unauthenticated remote attacker to upload arbitrary files to the file system.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 15:55 UTC
    CWE
    • CWE-434 - Unrestricted Upload of File with Dangerous Type
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: unspecified , < 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-08-05 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:42:19.024Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.myscada.org/version-8-20-0-released-security-update"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-33009",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:55:56.322846Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:21:47.203Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThan": "8.20.0",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2021-08-05T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "mySCADA myPRO versions prior to 8.20.0 allows an unauthenticated remote attacker to upload arbitrary files to the file system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "CWE-434: Unrestricted Upload of File with Dangerous Type",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-13T15:19:06.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.myscada.org/version-8-20-0-released-security-update"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users apply update v8.20.0 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "mySCADA myPRO Unrestricted Upload of File with Dangerous Type",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-08-05T21:32:00.000Z",
              "ID": "CVE-2021-33009",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO Unrestricted Upload of File with Dangerous Type"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "mySCADA myPRO versions prior to 8.20.0 allows an unauthenticated remote attacker to upload arbitrary files to the file system."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-434: Unrestricted Upload of File with Dangerous Type"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
                },
                {
                  "name": "https://www.myscada.org/version-8-20-0-released-security-update",
                  "refsource": "CONFIRM",
                  "url": "https://www.myscada.org/version-8-20-0-released-security-update"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users apply update v8.20.0 or later."
              }
            ],
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-33009",
        "datePublished": "2022-05-13T15:19:06.387Z",
        "dateReserved": "2021-05-13T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:21:47.203Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-33005 (GCVE-0-2021-33005)

    Vulnerability from cvelistv5 – Published: 2022-05-13 15:18 – Updated: 2025-04-16 16:21
    VLAI
    Title
    mySCADA myPRO Path Traversal
    Summary
    mySCADA myPRO versions prior to 8.20.0 allows an unauthenticated remote attacker to upload arbitrary files to arbitrary directories.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 15:56 UTC
    CWE
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: unspecified , < 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-08-05 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:42:19.949Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.myscada.org/version-8-20-0-released-security-update"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-33005",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:56:04.272607Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:21:55.101Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThan": "8.20.0",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2021-08-05T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "mySCADA myPRO versions prior to 8.20.0 allows an unauthenticated remote attacker to upload arbitrary files to arbitrary directories."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22: Path Traversal",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-13T15:18:39.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.myscada.org/version-8-20-0-released-security-update"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users apply update v8.20.0 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "mySCADA myPRO Path Traversal",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-08-05T21:32:00.000Z",
              "ID": "CVE-2021-33005",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO Path Traversal"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "mySCADA myPRO versions prior to 8.20.0 allows an unauthenticated remote attacker to upload arbitrary files to arbitrary directories."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-22: Path Traversal"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
                },
                {
                  "name": "https://www.myscada.org/version-8-20-0-released-security-update",
                  "refsource": "CONFIRM",
                  "url": "https://www.myscada.org/version-8-20-0-released-security-update"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users apply update v8.20.0 or later."
              }
            ],
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-33005",
        "datePublished": "2022-05-13T15:18:40.002Z",
        "dateReserved": "2021-05-13T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:21:55.101Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-27505 (GCVE-0-2021-27505)

    Vulnerability from cvelistv5 – Published: 2022-05-13 15:17 – Updated: 2025-04-16 16:22
    VLAI
    Title
    mySCADA myPRO Exposure of Information Through Directory Listing
    Summary
    mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive directory listing information.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 15:56 UTC
    CWE
    • CWE-548 - Exposure of Information Through Directory Listing
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: unspecified , < 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-08-05 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T21:26:10.394Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.myscada.org/version-8-20-0-released-security-update"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-27505",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:56:11.504847Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:22:03.550Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThan": "8.20.0",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2021-08-05T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive directory listing information."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-548",
                  "description": "CWE-548: Exposure of Information Through Directory Listing",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-13T15:17:59.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.myscada.org/version-8-20-0-released-security-update"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users apply update v8.20.0 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "mySCADA myPRO Exposure of Information Through Directory Listing",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-08-05T21:32:00.000Z",
              "ID": "CVE-2021-27505",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO Exposure of Information Through Directory Listing"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive directory listing information."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-548: Exposure of Information Through Directory Listing"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-217-03"
                },
                {
                  "name": "https://www.myscada.org/version-8-20-0-released-security-update",
                  "refsource": "CONFIRM",
                  "url": "https://www.myscada.org/version-8-20-0-released-security-update"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users apply update v8.20.0 or later."
              }
            ],
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-27505",
        "datePublished": "2022-05-13T15:17:59.788Z",
        "dateReserved": "2021-02-19T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:22:03.550Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-0999 (GCVE-0-2022-0999)

    Vulnerability from cvelistv5 – Published: 2022-04-11 19:38 – Updated: 2025-04-16 17:56
    VLAI
    Title
    mySCADA myPRO Command Injection
    Summary
    An authenticated user may be able to misuse parameters to inject arbitrary operating system commands into mySCADA myPRO versions 8.25.0 and prior.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 17:29 UTC
    CWE
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: 5.59 , ≤ 8.25.0 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:47:43.250Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-083-02"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-0999",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:56.858145Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:56:13.569Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThanOrEqual": "8.25.0",
                  "status": "affected",
                  "version": "5.59",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An authenticated user may be able to misuse parameters to inject arbitrary operating system commands into mySCADA myPRO versions 8.25.0 and prior."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77: Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-11T19:38:30.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-083-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users upgrade to version 8.26 or higher. For more information, contact mySCADA technical support. mySCADA will also send security advice by email to all registered users.\n"
            }
          ],
          "source": {
            "advisory": "ICSA-22-083-02",
            "discovery": "EXTERNAL"
          },
          "title": "mySCADA myPRO  Command Injection",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2022-0999",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO  Command Injection"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "5.59",
                                "version_value": "8.25.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported this vulnerability to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An authenticated user may be able to misuse parameters to inject arbitrary operating system commands into mySCADA myPRO versions 8.25.0 and prior."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-77: Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-083-02",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-083-02"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users upgrade to version 8.26 or higher. For more information, contact mySCADA technical support. mySCADA will also send security advice by email to all registered users.\n"
              }
            ],
            "source": {
              "advisory": "ICSA-22-083-02",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-0999",
        "datePublished": "2022-04-11T19:38:30.000Z",
        "dateReserved": "2022-03-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:56:13.569Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43985 (GCVE-0-2021-43985)

    Vulnerability from cvelistv5 – Published: 2021-12-23 19:48 – Updated: 2024-09-16 17:14
    VLAI
    Title
    mySCADA myPRO
    Summary
    An unauthenticated remote attacker can access mySCADA myPRO Versions 8.20.0 and prior without any form of authentication or authorization.
    CWE
    • CWE-288 - Authentication Bypass Using an Alternate Path or Channel
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: All , ≤ 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-12-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.143Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThanOrEqual": "8.20.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-12-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An unauthenticated remote attacker can access mySCADA myPRO Versions 8.20.0 and prior without any form of authentication or authorization."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-288",
                  "description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-23T19:48:40.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
            }
          ],
          "source": {
            "advisory": "ICSA-21-355-01",
            "discovery": "UNKNOWN"
          },
          "title": "mySCADA myPRO",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-12-21T17:26:00.000Z",
              "ID": "CVE-2021-43985",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "All",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An unauthenticated remote attacker can access mySCADA myPRO Versions 8.20.0 and prior without any form of authentication or authorization."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-288 Authentication Bypass Using an Alternate Path or Channel"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
              }
            ],
            "source": {
              "advisory": "ICSA-21-355-01",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43985",
        "datePublished": "2021-12-23T19:48:40.631Z",
        "dateReserved": "2021-11-17T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:14:15.304Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43989 (GCVE-0-2021-43989)

    Vulnerability from cvelistv5 – Published: 2021-12-23 19:48 – Updated: 2024-09-16 19:56
    VLAI
    Title
    mySCADA myPRO
    Summary
    mySCADA myPRO Versions 8.20.0 and prior stores passwords using MD5, which may allow an attacker to crack the previously retrieved password hashes.
    CWE
    • CWE-916 - Use of Password Hash With Insufficient Computational Effort
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: All , ≤ 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-12-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.125Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThanOrEqual": "8.20.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-12-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "mySCADA myPRO Versions 8.20.0 and prior stores passwords using MD5, which may allow an attacker to crack the previously retrieved password hashes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-916",
                  "description": "CWE-916 Use of Password Hash With Insufficient Computational Effort",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-23T19:48:39.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
            }
          ],
          "source": {
            "advisory": "ICSA-21-355-01",
            "discovery": "UNKNOWN"
          },
          "title": "mySCADA myPRO",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-12-21T17:26:00.000Z",
              "ID": "CVE-2021-43989",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "All",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "mySCADA myPRO Versions 8.20.0 and prior stores passwords using MD5, which may allow an attacker to crack the previously retrieved password hashes."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-916 Use of Password Hash With Insufficient Computational Effort"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
              }
            ],
            "source": {
              "advisory": "ICSA-21-355-01",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43989",
        "datePublished": "2021-12-23T19:48:39.913Z",
        "dateReserved": "2021-11-17T00:00:00.000Z",
        "dateUpdated": "2024-09-16T19:56:02.446Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43981 (GCVE-0-2021-43981)

    Vulnerability from cvelistv5 – Published: 2021-12-23 19:48 – Updated: 2024-09-16 20:12
    VLAI
    Title
    mySCADA myPRO
    Summary
    mySCADA myPRO: Versions 8.20.0 and prior has a feature to send emails, which may allow an attacker to inject arbitrary operating system commands through a specific parameter.
    CWE
    • CWE-78 - OS Command Injection
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: All , ≤ 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-12-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.144Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThanOrEqual": "8.20.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-12-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "mySCADA myPRO: Versions 8.20.0 and prior has a feature to send emails, which may allow an attacker to inject arbitrary operating system commands through a specific parameter."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-23T19:48:39.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
            }
          ],
          "source": {
            "advisory": "ICSA-21-355-01",
            "discovery": "UNKNOWN"
          },
          "title": "mySCADA myPRO",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-12-21T17:26:00.000Z",
              "ID": "CVE-2021-43981",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "All",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "mySCADA myPRO: Versions 8.20.0 and prior has a feature to send emails, which may allow an attacker to inject arbitrary operating system commands through a specific parameter."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-78 OS Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
              }
            ],
            "source": {
              "advisory": "ICSA-21-355-01",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43981",
        "datePublished": "2021-12-23T19:48:39.215Z",
        "dateReserved": "2021-11-17T00:00:00.000Z",
        "dateUpdated": "2024-09-16T20:12:37.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-44453 (GCVE-0-2021-44453)

    Vulnerability from cvelistv5 – Published: 2021-12-23 19:48 – Updated: 2024-09-17 01:46
    VLAI
    Title
    mySCADA myPRO
    Summary
    mySCADA myPRO: Versions 8.20.0 and prior has a vulnerable debug interface which includes a ping utility, which may allow an attacker to inject arbitrary operating system commands.
    CWE
    • CWE-78 - OS Command Injection
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: All , ≤ 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-12-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:25:16.514Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThanOrEqual": "8.20.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-12-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "mySCADA myPRO: Versions 8.20.0 and prior has a vulnerable debug interface which includes a ping utility, which may allow an attacker to inject arbitrary operating system commands."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-23T19:48:38.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
            }
          ],
          "source": {
            "advisory": "ICSA-21-355-01",
            "discovery": "UNKNOWN"
          },
          "title": "mySCADA myPRO",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-12-21T17:26:00.000Z",
              "ID": "CVE-2021-44453",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "All",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "mySCADA myPRO: Versions 8.20.0 and prior has a vulnerable debug interface which includes a ping utility, which may allow an attacker to inject arbitrary operating system commands."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-78 OS Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
              }
            ],
            "source": {
              "advisory": "ICSA-21-355-01",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-44453",
        "datePublished": "2021-12-23T19:48:38.488Z",
        "dateReserved": "2021-11-30T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:46:17.937Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43984 (GCVE-0-2021-43984)

    Vulnerability from cvelistv5 – Published: 2021-12-23 19:48 – Updated: 2024-09-16 23:30
    VLAI
    Title
    mySCADA myPRO
    Summary
    mySCADA myPRO: Versions 8.20.0 and prior has a feature where the firmware can be updated, which may allow an attacker to inject arbitrary operating system commands through a specific parameter.
    CWE
    • CWE-78 - OS Command Injection
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: All , ≤ 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-12-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.114Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThanOrEqual": "8.20.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-12-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "mySCADA myPRO: Versions 8.20.0 and prior has a feature where the firmware can be updated, which may allow an attacker to inject arbitrary operating system commands through a specific parameter."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-23T19:48:37.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
            }
          ],
          "source": {
            "advisory": "ICSA-21-355-01",
            "discovery": "UNKNOWN"
          },
          "title": "mySCADA myPRO",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-12-21T17:26:00.000Z",
              "ID": "CVE-2021-43984",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "All",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "mySCADA myPRO: Versions 8.20.0 and prior has a feature where the firmware can be updated, which may allow an attacker to inject arbitrary operating system commands through a specific parameter."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-78 OS Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
              }
            ],
            "source": {
              "advisory": "ICSA-21-355-01",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43984",
        "datePublished": "2021-12-23T19:48:37.725Z",
        "dateReserved": "2021-11-17T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:30:31.442Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-22657 (GCVE-0-2021-22657)

    Vulnerability from cvelistv5 – Published: 2021-12-23 19:48 – Updated: 2024-09-17 00:21
    VLAI
    Title
    mySCADA myPRO
    Summary
    mySCADA myPRO: Versions 8.20.0 and prior has a feature where the API password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter.
    CWE
    • CWE-78 - OS Command Injection
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: All , ≤ 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-12-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:51:05.997Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThanOrEqual": "8.20.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-12-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "mySCADA myPRO: Versions 8.20.0 and prior has a feature where the API password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-23T19:48:36.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
            }
          ],
          "source": {
            "advisory": "ICSA-21-355-01",
            "discovery": "UNKNOWN"
          },
          "title": "mySCADA myPRO",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-12-21T17:26:00.000Z",
              "ID": "CVE-2021-22657",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "All",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "mySCADA myPRO: Versions 8.20.0 and prior has a feature where the API password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-78 OS Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
              }
            ],
            "source": {
              "advisory": "ICSA-21-355-01",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-22657",
        "datePublished": "2021-12-23T19:48:36.843Z",
        "dateReserved": "2021-01-05T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:21:11.417Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43987 (GCVE-0-2021-43987)

    Vulnerability from cvelistv5 – Published: 2021-12-23 19:48 – Updated: 2024-09-16 23:35
    VLAI
    Title
    mySCADA myPRO
    Summary
    An additional, nondocumented administrative account exists in mySCADA myPRO Versions 8.20.0 and prior that is not exposed through the web interface, which cannot be deleted or changed through the regular web interface.
    CWE
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: All , ≤ 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-12-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.102Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThanOrEqual": "8.20.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-12-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An additional, nondocumented administrative account exists in mySCADA myPRO Versions 8.20.0 and prior that is not exposed through the web interface, which cannot be deleted or changed through the regular web interface."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-912",
                  "description": "CWE-912 Hidden Functionality",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-23T19:48:36.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
            }
          ],
          "source": {
            "advisory": "ICSA-21-355-01",
            "discovery": "UNKNOWN"
          },
          "title": "mySCADA myPRO",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-12-21T17:26:00.000Z",
              "ID": "CVE-2021-43987",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "All",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An additional, nondocumented administrative account exists in mySCADA myPRO Versions 8.20.0 and prior that is not exposed through the web interface, which cannot be deleted or changed through the regular web interface."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-912 Hidden Functionality"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
              }
            ],
            "source": {
              "advisory": "ICSA-21-355-01",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43987",
        "datePublished": "2021-12-23T19:48:36.147Z",
        "dateReserved": "2021-11-17T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:35:29.605Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-23198 (GCVE-0-2021-23198)

    Vulnerability from cvelistv5 – Published: 2021-12-23 19:48 – Updated: 2024-09-16 16:23
    VLAI
    Title
    mySCADA myPRO
    Summary
    mySCADA myPRO: Versions 8.20.0 and prior has a feature where the password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter.
    CWE
    • CWE-78 - OS Command Injection
    Assigner
    icscert CNA
    References
    Impacted products
    Vendor Product Version
    mySCADA myPRO Affected: All , ≤ 8.20.0 (custom)
    Create a notification for this product.
    Date Public
    2021-12-21 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T19:05:55.652Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "myPRO",
              "vendor": "mySCADA",
              "versions": [
                {
                  "lessThanOrEqual": "8.20.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-12-21T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "mySCADA myPRO: Versions 8.20.0 and prior has a feature where the password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-12-23T19:48:35.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
            }
          ],
          "source": {
            "advisory": "ICSA-21-355-01",
            "discovery": "UNKNOWN"
          },
          "title": "mySCADA myPRO",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2021-12-21T17:26:00.000Z",
              "ID": "CVE-2021-23198",
              "STATE": "PUBLIC",
              "TITLE": "mySCADA myPRO"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "myPRO",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "All",
                                "version_value": "8.20.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "mySCADA"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "mySCADA myPRO: Versions 8.20.0 and prior has a feature where the password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-78 OS Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-355-01"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "mySCADA recommends users upgrade to Version 8.22.0 or higher. For more information, contact mySCADA technical support."
              }
            ],
            "source": {
              "advisory": "ICSA-21-355-01",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-23198",
        "datePublished": "2021-12-23T19:48:35.400Z",
        "dateReserved": "2021-12-03T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:23:34.792Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }