2 vulnerabilities found for SpaceLogic AS-P by Schneider Electric

CVE-2024-5557 (GCVE-0-2024-5557)
Vulnerability from cvelistv5
Published
2024-06-12 16:28
Modified
2024-08-01 21:18
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Summary
CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause exposure of SNMP credentials when an attacker has access to the controller logs.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-b:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-b",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-p:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-p",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5557",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:09:17.413313Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T18:09:28.568Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.830Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-P",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-B",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause\nexposure of SNMP credentials when an attacker has access to the controller logs."
            }
          ],
          "value": "CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause\nexposure of SNMP credentials when an attacker has access to the controller logs."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-13T19:01:56.888Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-5557",
    "datePublished": "2024-06-12T16:28:56.844Z",
    "dateReserved": "2024-05-31T06:58:40.277Z",
    "dateUpdated": "2024-08-01T21:18:06.830Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5558 (GCVE-0-2024-5558)
Vulnerability from cvelistv5
Published
2024-06-12 16:26
Modified
2024-08-01 21:18
CWE
  • CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Summary
CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could cause escalation of privileges when an attacker abuses a limited admin account.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-b:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-b",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:schneider-electric:spacelogic_as-p:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "spacelogic_as-p",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "5.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5558",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T18:07:10.554620Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T16:20:36.411Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.335Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-P",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SpaceLogic AS-B",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V5.0.3 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nCWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could\ncause escalation of privileges when an attacker abuses a limited admin account.\n\n"
            }
          ],
          "value": "CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could\ncause escalation of privileges when an attacker abuses a limited admin account."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-367",
              "description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T16:26:26.294Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-04.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-5558",
    "datePublished": "2024-06-12T16:26:26.294Z",
    "dateReserved": "2024-05-31T06:58:47.453Z",
    "dateUpdated": "2024-08-01T21:18:06.335Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}