Refine your search
1 vulnerability found for Omada Software Controller (Linux) by TP-Link Systems Inc.
CVE-2026-84941 (GCVE-0-2026-84941)
Vulnerability from cvelistv5
Published
2026-09-10 23:35
Modified
2026-09-11 13:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-611 - Improper restriction of XML external entity reference
Summary
An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TP-Link Systems Inc. | Omada Software Controller (Windows) |
Version: 0 < 6.2.14.11 |
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-84941",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-11T13:10:27.244979Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-11T13:16:12.359Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Omada Controller"
],
"product": "Omada Software Controller (Windows)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "6.2.14.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Omada Controller"
],
"product": "Omada Software Controller (Linux)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "6.2.14.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Omada Controller"
],
"product": "OC2000 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.41.11 Build 20260711",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Omada Controller"
],
"product": "OC2000 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.26.11 Build 20260711",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Omada Controller"
],
"product": "OC200 v3",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.3.11 Build 20260711",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Omada Controller"
],
"product": "OC220 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.6.11 Build 20260711",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Omada Controller"
],
"product": "OC220 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.5.11 Build 20260711",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Omada Controller"
],
"product": "OC300 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.35.11 Build 20260711",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Omada Controller"
],
"product": "OC400 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.13.11 Build 20260711",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "erikdejong"
},
{
"lang": "en",
"type": "finder",
"value": "mattgsys"
},
{
"lang": "en",
"type": "finder",
"value": "eslam moneer (tohtmosiii)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eAn information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.\u003c/div\u003e"
}
],
"value": "An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information."
}
],
"impacts": [
{
"capecId": "CAPEC-221",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-221 Data Serialization External Entities Blowup"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611 Improper restriction of XML external entity reference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T23:35:53.023Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://support.omadanetworks.com/en/download/software/omada-controller"
},
{
"tags": [
"patch"
],
"url": "https://support.omadanetworks.com/us/download/software/omada-controller"
},
{
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/en/support/download/"
},
{
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/us/support/download/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/133722/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2026-84941",
"datePublished": "2026-09-10T23:35:53.023Z",
"dateReserved": "2026-09-02T16:45:11.015Z",
"dateUpdated": "2026-09-11T13:16:12.359Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}