Search
Find a vulnerability
Search criteria
9 vulnerabilities found for Infantia by CompuGroup Medical
CVE-2026-118795 (GCVE-0-2026-118795)
Vulnerability from cvelistv5 – Published: 2026-11-09 12:04 – Updated: 2026-11-09 15:25
VLAI
EPSS
VEX
Title
AIS stores authorization state in locally modifiable databases
Summary
Administrative roles and module permissions are stored in mutable local database fields, allowing privilege escalation for attackers with database write access.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-09 15:04 UTC
CWE
Assigner
ENISA
CNA
References
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 6.09.1
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 6.09.1
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 8.33.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-118795",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-09T15:04:53.696870Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T15:25:06.888Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "6.09.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "6.09.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "8.33.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Marco Sala"
},
{
"lang": "en",
"type": "coordinator",
"value": "CSIRT-IT"
},
{
"lang": "en",
"type": "finder",
"value": "ApoCert srl"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Administrative roles and module permissions are stored in mutable local database fields, allowing privilege escalation for attackers with database write access."
}
],
"value": "Administrative roles and module permissions are stored in mutable local database fields, allowing privilege escalation for attackers with database write access."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-602",
"description": "CWE-602",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T12:04:53.081Z",
"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"shortName": "ENISA"
},
"references": [
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
},
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "AIS stores authorization state in locally modifiable databases",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"assignerShortName": "ENISA",
"cveId": "CVE-2026-118795",
"datePublished": "2026-11-09T12:04:53.081Z",
"dateReserved": "2026-10-28T19:54:01.399Z",
"dateUpdated": "2026-11-09T15:25:06.888Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-118468 (GCVE-0-2026-118468)
Vulnerability from cvelistv5 – Published: 2026-11-09 11:58 – Updated: 2026-11-09 11:58
VLAI
EPSS
VEX
Title
AIS XML parsers allow external entity resolution
Summary
XML parsers process attacker-influenced update manifests or network responses with external entity resolution enabled, potentially allowing XML External Entity (XXE) attacks.
Severity
CWE
Assigner
ENISA
CNA
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 6.01.1
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 6.01.1
(semver)
|
|
| CompuGroup Medical | Phronesis |
Affected:
0 , ≤ 4.51.0
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 8.33.2
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "6.01.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "6.01.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Phronesis",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "4.51.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "8.33.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Marco Sala"
},
{
"lang": "en",
"type": "coordinator",
"value": "CSIRT-IT"
},
{
"lang": "en",
"type": "finder",
"value": "ApoCert srl"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "XML parsers process attacker-influenced update manifests or network responses with external entity resolution enabled, potentially allowing XML External Entity (XXE) attacks."
}
],
"value": "XML parsers process attacker-influenced update manifests or network responses with external entity resolution enabled, potentially allowing XML External Entity (XXE) attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T11:58:12.438Z",
"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"shortName": "ENISA"
},
"references": [
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
},
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "AIS XML parsers allow external entity resolution",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"assignerShortName": "ENISA",
"cveId": "CVE-2026-118468",
"datePublished": "2026-11-09T11:58:12.438Z",
"dateReserved": "2026-10-28T08:46:25.411Z",
"dateUpdated": "2026-11-09T11:58:12.438Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-118467 (GCVE-0-2026-118467)
Vulnerability from cvelistv5 – Published: 2026-11-09 11:56 – Updated: 2026-11-09 11:56
VLAI
EPSS
VEX
Title
AIS products expose clinical and personal data via logs and telemetry
Summary
Shared telemetry and logging components store or transmit patient and doctor identifiers, clinical information, and low-entropy identifiers without adequate pseudonymization or protection.
Severity
CWE
Assigner
ENISA
CNA
References
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 1.3.1
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 1.3.1
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 1.3.1
(semver)
|
|
| CompuGroup Medical | Phronesis |
Affected:
0 , ≤ 1.3.1
(semver)
|
|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Phronesis |
Affected:
0 , ≤ 5.1.1
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"packageName": "ImxTracing",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.3.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "ImxTracing",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.3.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "ImxTracing",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.3.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "ImxTracing",
"product": "Phronesis",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.3.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Phronesis",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Marco Sala"
},
{
"lang": "en",
"type": "coordinator",
"value": "CSIRT-IT"
},
{
"lang": "en",
"type": "finder",
"value": "ApoCert srl"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eShared telemetry and logging components store or transmit patient and doctor identifiers, clinical information, and low-entropy identifiers without adequate pseudonymization or protection.\u003c/div\u003e"
}
],
"value": "Shared telemetry and logging components store or transmit patient and doctor identifiers, clinical information, and low-entropy identifiers without adequate pseudonymization or protection."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T11:56:43.635Z",
"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"shortName": "ENISA"
},
"references": [
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
},
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "AIS products expose clinical and personal data via logs and telemetry",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"assignerShortName": "ENISA",
"cveId": "CVE-2026-118467",
"datePublished": "2026-11-09T11:56:43.635Z",
"dateReserved": "2026-10-28T08:46:25.411Z",
"dateUpdated": "2026-11-09T11:56:43.635Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-118465 (GCVE-0-2026-118465)
Vulnerability from cvelistv5 – Published: 2026-11-09 11:53 – Updated: 2026-11-09 11:53
VLAI
EPSS
VEX
Title
AIS products use vendor-wide hard-coded database credentials
Summary
Shared components expose hard-coded Access, workgroup, CCBasic, DBISAM, and related database credentials that are identical across installations.
Severity
CWE
Assigner
ENISA
CNA
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Phronesis |
Affected:
0 , ≤ 5.1.1
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Phronesis",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Marco Sala"
},
{
"lang": "en",
"type": "coordinator",
"value": "CSIRT-IT"
},
{
"lang": "en",
"type": "finder",
"value": "ApoCert srl"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Shared components expose hard-coded Access, workgroup, CCBasic, DBISAM, and related database credentials that are identical across installations."
}
],
"value": "Shared components expose hard-coded Access, workgroup, CCBasic, DBISAM, and related database credentials that are identical across installations."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T11:53:06.273Z",
"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"shortName": "ENISA"
},
"references": [
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
},
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "AIS products use vendor-wide hard-coded database credentials",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"assignerShortName": "ENISA",
"cveId": "CVE-2026-118465",
"datePublished": "2026-11-09T11:53:06.273Z",
"dateReserved": "2026-10-28T08:46:25.411Z",
"dateUpdated": "2026-11-09T11:53:06.273Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-118464 (GCVE-0-2026-118464)
Vulnerability from cvelistv5 – Published: 2026-11-09 11:52 – Updated: 2026-11-09 11:52
VLAI
EPSS
VEX
Title
AIS shared cryptographic services use fixed cryptographic secrets
Summary
Shared cryptographic services use fixed vendor-wide secrets, deterministic IVs, null salts, and reversible transformations to protect credentials, IPC data, configuration values, and clinical fields.
Severity
CWE
Assigner
ENISA
CNA
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Phronesis |
Affected:
0 , ≤ 5.1.1
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Phronesis",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Marco Sala"
},
{
"lang": "en",
"type": "coordinator",
"value": "CSIRT-IT"
},
{
"lang": "en",
"type": "finder",
"value": "ApoCert srl"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Shared cryptographic services use fixed vendor-wide secrets, deterministic IVs, null salts, and reversible transformations to protect credentials, IPC data, configuration values, and clinical fields."
}
],
"value": "Shared cryptographic services use fixed vendor-wide secrets, deterministic IVs, null salts, and reversible transformations to protect credentials, IPC data, configuration values, and clinical fields."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T11:52:32.717Z",
"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"shortName": "ENISA"
},
"references": [
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
},
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "AIS shared cryptographic services use fixed cryptographic secrets",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"assignerShortName": "ENISA",
"cveId": "CVE-2026-118464",
"datePublished": "2026-11-09T11:52:32.717Z",
"dateReserved": "2026-10-28T08:46:25.411Z",
"dateUpdated": "2026-11-09T11:52:32.717Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-118462 (GCVE-0-2026-118462)
Vulnerability from cvelistv5 – Published: 2026-11-09 11:51 – Updated: 2026-11-09 11:51
VLAI
EPSS
VEX
Title
AIS update mechanism executes unverified code
Summary
Update components download and execute code without proper authenticity verification, relying on ignored hashes or forgeable checksums. Some update paths also permit archive traversal or script execution.
Severity
CWE
Assigner
ENISA
CNA
References
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 1.3.0
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 1.3.0
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 1.3.0
(semver)
|
|
| CompuGroup Medical | Phronesis |
Affected:
0 , ≤ 1.3.0
(semver)
|
|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 2.12.0
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 2.12.0
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 2.12.0
(semver)
|
|
| CompuGroup Medical | Phronesis |
Affected:
0 , ≤ 2.12.0
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"packageName": "cgm.files.delivery",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.3.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.files.delivery",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.3.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.files.delivery",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.3.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.files.delivery",
"product": "Phronesis",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.3.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.liveupdates",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "2.12.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.liveupdates",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "2.12.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.liveupdates",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "2.12.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.liveupdates",
"product": "Phronesis",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "2.12.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Marco Sala"
},
{
"lang": "en",
"type": "coordinator",
"value": "CSIRT-IT"
},
{
"lang": "en",
"type": "finder",
"value": "ApoCert srl"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update components download and execute code without proper authenticity verification, relying on ignored hashes or forgeable checksums. Some update paths also permit archive traversal or script execution."
}
],
"value": "Update components download and execute code without proper authenticity verification, relying on ignored hashes or forgeable checksums. Some update paths also permit archive traversal or script execution."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T11:51:58.643Z",
"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"shortName": "ENISA"
},
"references": [
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
},
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "AIS update mechanism executes unverified code",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"assignerShortName": "ENISA",
"cveId": "CVE-2026-118462",
"datePublished": "2026-11-09T11:51:58.643Z",
"dateReserved": "2026-10-28T08:46:25.411Z",
"dateUpdated": "2026-11-09T11:51:58.643Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-118461 (GCVE-0-2026-118461)
Vulnerability from cvelistv5 – Published: 2026-11-09 11:49 – Updated: 2026-11-09 11:49
VLAI
EPSS
VEX
Title
AIS PersonnelService client performs unauthenticated doctor-specific operations
Summary
The shared client accepts caller-controlled doctor identifiers for read and write operations without requiring authentication or authorization credentials.
Severity
CWE
Assigner
ENISA
CNA
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 1.10.0
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 1.10.0
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 1.10.0
(semver)
|
|
| CompuGroup Medical | Phronesis |
Affected:
0 , ≤ 1.10.0
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.connector",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.10.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.connector",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.10.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.connector",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.10.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.connector",
"product": "Phronesis",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "1.10.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Marco Sala"
},
{
"lang": "en",
"type": "coordinator",
"value": "CSIRT-IT"
},
{
"lang": "en",
"type": "finder",
"value": "ApoCert srl"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The shared client accepts caller-controlled doctor identifiers for read and write operations without requiring authentication or authorization credentials."
}
],
"value": "The shared client accepts caller-controlled doctor identifiers for read and write operations without requiring authentication or authorization credentials."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8,
"baseSeverity": "HIGH",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T11:49:12.134Z",
"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"shortName": "ENISA"
},
"references": [
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
},
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "AIS PersonnelService client performs unauthenticated doctor-specific operations",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"assignerShortName": "ENISA",
"cveId": "CVE-2026-118461",
"datePublished": "2026-11-09T11:49:12.134Z",
"dateReserved": "2026-10-28T08:46:25.411Z",
"dateUpdated": "2026-11-09T11:49:12.134Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-118460 (GCVE-0-2026-118460)
Vulnerability from cvelistv5 – Published: 2026-11-09 11:48 – Updated: 2026-11-09 11:48
VLAI
EPSS
VEX
Title
AIS embedded private keys enable practitioner impersonation
Summary
Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests.
Severity
CWE
Assigner
ENISA
CNA
References
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 6.09.1
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 6.09.1
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 6.09.1
(semver)
|
|
| CompuGroup Medical | Phronesis |
Affected:
0 , ≤ 6.09.1
(semver)
|
|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Phronesis |
Affected:
0 , ≤ 5.1.1
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.farmaci",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "6.09.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.farmaci",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "6.09.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.farmaci",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "6.09.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.farmaci",
"product": "Phronesis",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "6.09.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Phronesis",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Marco Sala"
},
{
"lang": "en",
"type": "coordinator",
"value": "CSIRT-IT"
},
{
"lang": "en",
"type": "finder",
"value": "ApoCert srl"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests."
}
],
"value": "Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8,
"baseSeverity": "HIGH",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T11:48:31.899Z",
"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"shortName": "ENISA"
},
"references": [
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
},
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "AIS embedded private keys enable practitioner impersonation",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"assignerShortName": "ENISA",
"cveId": "CVE-2026-118460",
"datePublished": "2026-11-09T11:48:31.899Z",
"dateReserved": "2026-10-28T08:46:25.411Z",
"dateUpdated": "2026-11-09T11:48:31.899Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-118459 (GCVE-0-2026-118459)
Vulnerability from cvelistv5 – Published: 2026-11-09 11:47 – Updated: 2026-11-09 11:47
VLAI
EPSS
VEX
Title
AIS PasswordSOS permits authentication without legitimate credentials
Summary
A time-derived emergency password can be derived from publicly available application code, enabling authentication without legitimate credentials.
Severity
CWE
Assigner
ENISA
CNA
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| CompuGroup Medical | Infantia |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Profim |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Venere |
Affected:
0 , ≤ 5.1.1
(semver)
|
|
| CompuGroup Medical | Phronesis |
Affected:
0 , ≤ 5.1.1
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Infantia",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Profim",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Venere",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"product": "Phronesis",
"vendor": "CompuGroup Medical",
"versions": [
{
"lessThanOrEqual": "5.1.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Marco Sala"
},
{
"lang": "en",
"type": "coordinator",
"value": "CSIRT-IT"
},
{
"lang": "en",
"type": "finder",
"value": "ApoCert srl"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A time-derived emergency password can be derived from publicly available application code, enabling authentication without legitimate credentials."
}
],
"value": "A time-derived emergency password can be derived from publicly available application code, enabling authentication without legitimate credentials."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-640",
"description": "CWE-640",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-09T11:47:11.721Z",
"orgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"shortName": "ENISA"
},
"references": [
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html"
},
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "AIS PasswordSOS permits authentication without legitimate credentials",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"assignerShortName": "ENISA",
"cveId": "CVE-2026-118459",
"datePublished": "2026-11-09T11:47:11.721Z",
"dateReserved": "2026-10-28T08:46:25.411Z",
"dateUpdated": "2026-11-09T11:47:11.721Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}