Summary
There is an improper authentication vulnerability in some Hikvision DVR products. Due to the improper implementation of authentication for the serial port, an attacker with physical access could exploit this vulnerability by connecting to the affected products and run a series of commands.
Impacted products
Vendor Product Version
Hikvision DS-7104HGHI-F1 Version: Versions below V4.30.122_201107 (including V4.30.122_201107)
Create a notification for this product.
   Hikvision DS-7204HGHI-F1 Version: Versions below V4.30.122_201107 (including V4.30.122_201107)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-66174",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-19T15:41:12.037984Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-287",
                "description": "CWE-287 Improper Authentication",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-19T15:41:32.976Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-7104HGHI-F1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.30.122_201107 (including V4.30.122_201107)"
            }
          ]
        },
        {
          "product": "DS-7204HGHI-F1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.30.122_201107 (including V4.30.122_201107)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aaron J Jose"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is an improper authentication vulnerability in some Hikvision DVR products. Due to the improper implementation of authentication for the serial port, an attacker with physical access could exploit this vulnerability by connecting to the affected products and run a series of commands."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-19T06:45:55.453Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/serial-port-privilege-escalation-vulnerabilities-in-some-hikvision-nvr-devices/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2025-66174",
    "datePublished": "2025-12-19T06:39:51.404Z",
    "dateReserved": "2025-11-24T08:59:35.903Z",
    "dateUpdated": "2025-12-19T15:41:32.976Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-66173 (GCVE-0-2025-66173)
Vulnerability from cvelistv5
Published
2025-12-19 06:39
Modified
2025-12-19 15:40
Summary
There is a privilege escalation vulnerability in some Hikvision DVR products. Due to the improper implementation of authentication for the serial port, an attacker with physical access could exploit this vulnerability by connecting to the affected products and gaining access to an unrestricted shell environment.
Impacted products
Vendor Product Version
Hikvision DS-7104HGHI-F1 Version: Versions below V4.30.122_201107 (including V4.30.122_201107)
Create a notification for this product.
   Hikvision DS-7204HGHI-F1 Version: Versions below V4.30.122_201107 (including V4.30.122_201107)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-66173",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-19T15:40:25.549400Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-269",
                "description": "CWE-269 Improper Privilege Management",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-19T15:40:52.217Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DS-7104HGHI-F1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.30.122_201107 (including V4.30.122_201107)"
            }
          ]
        },
        {
          "product": "DS-7204HGHI-F1",
          "vendor": "Hikvision",
          "versions": [
            {
              "status": "affected",
              "version": "Versions below V4.30.122_201107 (including V4.30.122_201107)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aaron J Jose"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a privilege escalation vulnerability in some Hikvision DVR products. Due to the improper implementation of authentication for the serial port, an attacker with physical access could exploit this vulnerability by connecting to the affected products and gaining access to an unrestricted shell environment."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-19T06:45:40.814Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/serial-port-privilege-escalation-vulnerabilities-in-some-hikvision-nvr-devices/"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2025-66173",
    "datePublished": "2025-12-19T06:39:38.504Z",
    "dateReserved": "2025-11-24T08:59:35.902Z",
    "dateUpdated": "2025-12-19T15:40:52.217Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}