CWE-685

Function Call With Incorrect Number of Arguments

The product calls a function, procedure, or routine, but the caller specifies too many arguments, or too few arguments, which may lead to undefined behavior and resultant weaknesses.

CVE-2026-11389 (GCVE-0-2026-11389)
Vulnerability from cvelistv5
Published
2026-09-22 17:50
Modified
2026-09-22 18:49
CWE
  • CWE-125 - Out-of-bounds Read
  • CWE-685 - Function Call With Incorrect Number of Arguments
  • CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Summary
Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type ('Type Confusion') vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers. This issue affects Connext Professional: from 7.4.0 before 7.7.0.1, from 7.3.0 before 7.3.1.6.
Impacted products
Vendor Product Version
RTI Connext Professional Version: 7.4.0   < 7.7.0.1
Version: 7.3.0   < 7.3.1.6
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11389",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-22T18:49:09.272083Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-22T18:49:15.593Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Core Libraries"
          ],
          "packageName": "connext_professional",
          "packageURL": "pkg:generic/connext_professional",
          "product": "Connext Professional",
          "vendor": "RTI",
          "versions": [
            {
              "lessThan": "7.7.0.1",
              "status": "affected",
              "version": "7.4.0",
              "versionType": "custom"
            },
            {
              "lessThan": "7.3.1.6",
              "status": "affected",
              "version": "7.3.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rti:connext_professional:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "7.7.0.1",
                  "versionStartIncluding": "7.4.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rti:connext_professional:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "7.3.1.6",
                  "versionStartIncluding": "7.3.0",
                  "vulnerable": true
                }
              ],
              "negated": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2026-09-15T17:47:56.507Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027) vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers.\u003cp\u003eThis issue affects Connext Professional: from 7.4.0 before 7.7.0.1, from 7.3.0 before 7.3.1.6.\u003c/p\u003e"
            }
          ],
          "value": "Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027) vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers. This issue affects Connext Professional: from 7.4.0 before 7.7.0.1, from 7.3.0 before 7.3.1.6."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-540",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-540 Overread Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "Security Extensions Enabled"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-685",
              "description": "CWE-685 Function Call With Incorrect Number of Arguments",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-22T17:50:16.392Z",
        "orgId": "3f572a00-62e2-4423-959a-7ea25eff1638",
        "shortName": "RTI"
      },
      "references": [
        {
          "url": "https://www.rti.com/vulnerabilities/#cve-2026-11389"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027) vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers.",
      "x_generator": {
        "engine": "RTI Lubna 1.18.7"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3f572a00-62e2-4423-959a-7ea25eff1638",
    "assignerShortName": "RTI",
    "cveId": "CVE-2026-11389",
    "datePublished": "2026-09-22T17:50:16.392Z",
    "dateReserved": "2026-06-05T15:43:42.378Z",
    "dateUpdated": "2026-09-22T18:49:15.593Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-18458 (GCVE-0-2026-18458)
Vulnerability from cvelistv5
Published
2026-09-22 17:50
Modified
2026-09-22 18:48
CWE
  • CWE-125 - Out-of-bounds Read
  • CWE-685 - Function Call With Incorrect Number of Arguments
  • CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Summary
Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type ('Type Confusion') vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers. This issue affects Connext Professional: from 7.4.0 before 7.7.0.1, from 7.3.0 before 7.3.1.6, from 6.1.2.21 before 6.1.*.
Impacted products
Vendor Product Version
RTI Connext Professional Version: 7.4.0   < 7.7.0.1
Version: 7.3.0   < 7.3.1.6
Version: 6.1.2.21   < 6.1.*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-18458",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-22T18:48:21.717194Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-22T18:48:29.246Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Core Libraries"
          ],
          "packageName": "connext_professional",
          "packageURL": "pkg:generic/connext_professional",
          "product": "Connext Professional",
          "vendor": "RTI",
          "versions": [
            {
              "lessThan": "7.7.0.1",
              "status": "affected",
              "version": "7.4.0",
              "versionType": "custom"
            },
            {
              "lessThan": "7.3.1.6",
              "status": "affected",
              "version": "7.3.0",
              "versionType": "custom"
            },
            {
              "lessThan": "6.1.*",
              "status": "affected",
              "version": "6.1.2.21",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:rti:connext_professional:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "7.7.0.1",
                  "versionStartIncluding": "7.4.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rti:connext_professional:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "7.3.1.6",
                  "versionStartIncluding": "7.3.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:rti:connext_professional:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "6.1.*",
                  "versionStartIncluding": "6.1.2.21",
                  "vulnerable": true
                }
              ],
              "negated": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2026-09-15T17:47:50.129Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027) vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers.\u003cp\u003eThis issue affects Connext Professional: from 7.4.0 before 7.7.0.1, from 7.3.0 before 7.3.1.6, from 6.1.2.21 before 6.1.*.\u003c/p\u003e"
            }
          ],
          "value": "Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027) vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers. This issue affects Connext Professional: from 7.4.0 before 7.7.0.1, from 7.3.0 before 7.3.1.6, from 6.1.2.21 before 6.1.*."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-540",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-540 Overread Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "Security Extensions Enabled"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-685",
              "description": "CWE-685 Function Call With Incorrect Number of Arguments",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-22T17:50:17.977Z",
        "orgId": "3f572a00-62e2-4423-959a-7ea25eff1638",
        "shortName": "RTI"
      },
      "references": [
        {
          "url": "https://www.rti.com/vulnerabilities/#cve-2026-18458"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027) vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers.",
      "x_generator": {
        "engine": "RTI Lubna 1.18.7"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3f572a00-62e2-4423-959a-7ea25eff1638",
    "assignerShortName": "RTI",
    "cveId": "CVE-2026-18458",
    "datePublished": "2026-09-22T17:50:17.977Z",
    "dateReserved": "2026-07-31T07:29:34.430Z",
    "dateUpdated": "2026-09-22T18:48:29.246Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

Mitigation

Phase: Testing

Description:

  • Because this function call often produces incorrect behavior it will usually be detected during testing or normal operation of the product. During testing exercise all possible control paths will typically expose this weakness except in rare cases when the incorrect function call accidentally produces the correct results or if the provided argument type is very similar to the expected argument type.

No CAPEC attack patterns related to this CWE.

Back to CWE stats page