Common Weakness Enumeration

CWE-920

Weakness Allowed

Improper Restriction of Power Consumption

Abstraction: Base · Status: Incomplete

The product operates in an environment in which power is a limited resource that cannot be automatically replenished - or has financial restrictions - but the product does not properly restrict the amount of power that its operation consumes.

In environments such as embedded or mobile devices, power can be a limited resource such as a battery, which cannot be automatically replenished by the product itself, and the device might not always be directly attached to a reliable power source. If the product uses too much power too quickly, then this could cause the device (and subsequently, the product) to stop functioning until power is restored, or increase the financial burden on the device owner because of increased power costs.

Technical nuance

Various components of a product or device could consume power, such as:

Display

CPU

Disk I/O

GPS

Sound

Microphone

USB interface

Dimensions

  • Behavior-Property: Improper
  • Behavior-Type: Restriction
  • Resource-Type: Power
  • Behavior-Type: Consumption
Mapping guidance

This CWE entry is at the Base level of abstraction, which is a preferred level of abstraction for mapping to the root causes of vulnerabilities.

Carefully read both the name and description to ensure that this mapping is an appropriate fit. Do not try to 'force' a mapping to a lower-level Base/Variant simply to comply with this preferred level of abstraction.

Relationships and members
ChildOf: CWE-400 · View CWE-1000
ChildOf: CWE-400 · View CWE-1003
Modes of introduction
Architecture and Design
Content history
Submission: CWE Content Team · MITRE · 2013-06-11 · CWE 2.5
Contribution: "Mapping CWE to 62443" Sub-Working Group · CWE-CAPEC ICS/OT SIG · 2023-04-25 · CWE 4.11

Suggested mappings to ISA/IEC 62443.

Modification: CWE Content Team · MITRE · 2019-06-20 · CWE 3.3

updated Relationships

Modification: CWE Content Team · MITRE · 2020-02-24 · CWE 4.0

updated Applicable_Platforms, Relationships

Modification: CWE Content Team · MITRE · 2023-01-31 · CWE 4.10

updated Description

Modification: CWE Content Team · MITRE · 2023-04-27 · CWE 4.11

updated Relationships, Taxonomy_Mappings

Modification: CWE Content Team · MITRE · 2023-06-29 · CWE 4.12

updated Mapping_Notes

Modification: CWE Content Team · MITRE · 2025-12-11 · CWE 4.19

updated Weakness_Ordinalities

Modification: CWE Content Team · MITRE · 2026-10-28 · CWE 5.0

updated Common_Consequences, Description, Dimensions, Technical_Nuance

1 vulnerability references this CWE, most recent first.

CVE-2017-12714 (GCVE-0-2017-12714)

Vulnerability from cvelistv5 – Published: 2018-04-25 13:00 – Updated: 2024-09-17 00:16
VLAI
Summary
Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
Severity
No CVSS data available.
CWE
  • CWE-920 - Improper Restriction of power consumption CWE-920
Assigner
icscert CNA
References
Impacted products
Vendor Product Version
Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI. Affected: All versions of pacemakers manufactured prior to August 28, 2017
Create a notification for this product.
Date Public
2017-08-29 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T18:43:56.537Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
          },
          {
            "name": "100523",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100523"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
          "vendor": "Abbott Laboratories",
          "versions": [
            {
              "status": "affected",
              "version": "All versions of pacemakers manufactured prior to August 28, 2017"
            }
          ]
        }
      ],
      "datePublic": "2017-08-29T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted \"RF wake-up\" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-920",
              "description": "Improper Restriction of power consumption CWE-920",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-26T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
        },
        {
          "name": "100523",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100523"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2017-08-29T00:00:00",
          "ID": "CVE-2017-12714",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions of pacemakers manufactured prior to August 28, 2017"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Abbott Laboratories"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted \"RF wake-up\" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Restriction of power consumption CWE-920"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
            },
            {
              "name": "100523",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100523"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-12714",
    "datePublished": "2018-04-25T13:00:00.000Z",
    "dateReserved": "2017-08-09T00:00:00.000Z",
    "dateUpdated": "2024-09-17T00:16:50.163Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

No mitigation information available for this CWE.

No CAPEC attack patterns related to this CWE.