CWE-920
Weakness AllowedImproper Restriction of Power Consumption
Abstraction: Base · Status: Incomplete
The product operates in an environment in which power is a limited resource that cannot be automatically replenished - or has financial restrictions - but the product does not properly restrict the amount of power that its operation consumes.
In environments such as embedded or mobile devices, power can be a limited resource such as a battery, which cannot be automatically replenished by the product itself, and the device might not always be directly attached to a reliable power source. If the product uses too much power too quickly, then this could cause the device (and subsequently, the product) to stop functioning until power is restored, or increase the financial burden on the device owner because of increased power costs.
Technical nuance
Various components of a product or device could consume power, such as:
Display
CPU
Disk I/O
GPS
Sound
Microphone
USB interface
Dimensions
- Behavior-Property: Improper
- Behavior-Type: Restriction
- Resource-Type: Power
- Behavior-Type: Consumption
Mapping guidance
This CWE entry is at the Base level of abstraction, which is a preferred level of abstraction for mapping to the root causes of vulnerabilities.
Carefully read both the name and description to ensure that this mapping is an appropriate fit. Do not try to 'force' a mapping to a lower-level Base/Variant simply to comply with this preferred level of abstraction.
Modes of introduction
Content history
Suggested mappings to ISA/IEC 62443.
updated Relationships
updated Applicable_Platforms, Relationships
updated Description
updated Relationships, Taxonomy_Mappings
updated Mapping_Notes
updated Weakness_Ordinalities
updated Common_Consequences, Description, Dimensions, Technical_Nuance
1 vulnerability references this CWE, most recent first.
CVE-2017-12714 (GCVE-0-2017-12714)
Vulnerability from cvelistv5 – Published: 2018-04-25 13:00 – Updated: 2024-09-17 00:16- CWE-920 - Improper Restriction of power consumption CWE-920
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01 | x_refsource_MISC |
| http://www.securityfocus.com/bid/100523 | vdb-entryx_refsource_BID |
| Vendor | Product | Version | |
|---|---|---|---|
| Abbott Laboratories | Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI. |
Affected:
All versions of pacemakers manufactured prior to August 28, 2017
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T18:43:56.537Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/100523"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
"vendor": "Abbott Laboratories",
"versions": [
{
"status": "affected",
"version": "All versions of pacemakers manufactured prior to August 28, 2017"
}
]
}
],
"datePublic": "2017-08-29T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted \"RF wake-up\" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-920",
"description": "Improper Restriction of power consumption CWE-920",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-26T09:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/100523"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2017-08-29T00:00:00",
"ID": "CVE-2017-12714",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.",
"version": {
"version_data": [
{
"version_value": "All versions of pacemakers manufactured prior to August 28, 2017"
}
]
}
}
]
},
"vendor_name": "Abbott Laboratories"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted \"RF wake-up\" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Restriction of power consumption CWE-920"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-241-01"
},
{
"name": "100523",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/100523"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-12714",
"datePublished": "2018-04-25T13:00:00.000Z",
"dateReserved": "2017-08-09T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:16:50.163Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
No mitigation information available for this CWE.
No CAPEC attack patterns related to this CWE.