Common Weakness Enumeration
CWE-1390
Allowed-with-ReviewWeak Authentication
Abstraction: Class · Status: Incomplete
The product uses an authentication mechanism to restrict access to specific users or identities, but the mechanism does not sufficiently prove that the claimed identity is correct.
111 vulnerabilities reference this CWE, most recent first.
CVE-2022-43400 (GCVE-0-2022-43400)
Vulnerability from cvelistv5 – Published: 2022-10-21 00:00 – Updated: 2025-05-07 15:56
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Siveillance Video Mobile Server V2022 R2 (All versions < V22.2a (80)). The mobile server component of affected applications improperly handles the log in for Active Directory accounts that are part of Administrators group. This could allow an unauthenticated remote attacker to access the application without a valid account.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-07 15:56 UTC
CWE
- CWE-1390 - None
Assigner
siemens
CNA
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Siveillance Video Mobile Server V2022 R2 |
Affected:
All versions < V22.2a (80)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:32:58.062Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-640732.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-43400",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-07T15:56:21.699875Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-07T15:56:50.791Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Siveillance Video Mobile Server V2022 R2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V22.2a (80)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Siveillance Video Mobile Server V2022 R2 (All versions \u003c V22.2a (80)). The mobile server component of affected applications improperly handles the log in for Active Directory accounts that are part of Administrators group. This could allow an unauthenticated remote attacker to access the application without a valid account."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1390",
"description": "CWE-1390: None",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-21T00:00:00.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-640732.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43400",
"datePublished": "2022-10-21T00:00:00.000Z",
"dateReserved": "2022-10-18T00:00:00.000Z",
"dateUpdated": "2025-05-07T15:56:50.791Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
No mitigation information available for this CWE.
No CAPEC attack patterns related to this CWE.