Search

Find a vulnerability

Search criteria

    1 vulnerability found for eTRAKiT3 by Sungard

    CVE-2016-6566 (GCVE-0-2016-6566)

    Vulnerability from cvelistv5 – Published: 2018-07-13 20:00 – Updated: 2024-08-06 01:36
    VLAI
    Title
    The Sungard eTRAKiT3 software version 3.2.1.17 may be vulnerable to SQL injection which may allow a remote unauthenticated attacker to run a subset of SQL commands against the back-end database
    Summary
    The valueAsString parameter inside the JSON payload contained by the ucLogin_txtLoginId_ClientStat POST parameter of the Sungard eTRAKiT3 software version 3.2.1.17 is not properly validated. An unauthenticated remote attacker may be able to modify the POST request and insert a SQL query which may then be executed by the backend server. eTRAKiT 3.2.1.17 was tested, but other versions may also be vulnerable.
    Severity
    No CVSS data available.
    CWE
    Assigner
    certcc CNA
    References
    URL Tags
    https://www.kb.cert.org/vuls/id/846103 third-party-advisoryx_refsource_CERT-VN
    http://www.securityfocus.com/bid/94696 vdb-entryx_refsource_BID
    Impacted products
    Vendor Product Version
    Sungard eTRAKiT3 Affected: 3.2.1.17
    Create a notification for this product.
    Date Public
    2016-12-06 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T01:36:28.063Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VU#846103",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "https://www.kb.cert.org/vuls/id/846103"
              },
              {
                "name": "94696",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/94696"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "eTRAKiT3",
              "vendor": "Sungard",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.2.1.17"
                }
              ]
            }
          ],
          "datePublic": "2016-12-06T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The valueAsString parameter inside the JSON payload contained by the ucLogin_txtLoginId_ClientStat POST parameter of the Sungard eTRAKiT3 software version 3.2.1.17 is not properly validated. An unauthenticated remote attacker may be able to modify the POST request and insert a SQL query which may then be executed by the backend server. eTRAKiT 3.2.1.17 was tested, but other versions may also be vulnerable."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-07-14T09:57:01.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "name": "VU#846103",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "https://www.kb.cert.org/vuls/id/846103"
            },
            {
              "name": "94696",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/94696"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "The Sungard eTRAKiT3 software version 3.2.1.17 may be vulnerable to SQL injection which may allow a remote unauthenticated attacker to run a subset of SQL commands against the back-end database",
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2016-6566",
              "STATE": "PUBLIC",
              "TITLE": "The Sungard eTRAKiT3 software version 3.2.1.17 may be vulnerable to SQL injection which may allow a remote unauthenticated attacker to run a subset of SQL commands against the back-end database"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "eTRAKiT3",
                          "version": {
                            "version_data": [
                              {
                                "affected": "=",
                                "version_affected": "=",
                                "version_name": "3.2.1.17",
                                "version_value": "3.2.1.17"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Sungard"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The valueAsString parameter inside the JSON payload contained by the ucLogin_txtLoginId_ClientStat POST parameter of the Sungard eTRAKiT3 software version 3.2.1.17 is not properly validated. An unauthenticated remote attacker may be able to modify the POST request and insert a SQL query which may then be executed by the backend server. eTRAKiT 3.2.1.17 was tested, but other versions may also be vulnerable."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-89"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "VU#846103",
                  "refsource": "CERT-VN",
                  "url": "https://www.kb.cert.org/vuls/id/846103"
                },
                {
                  "name": "94696",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/94696"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2016-6566",
        "datePublished": "2018-07-13T20:00:00.000Z",
        "dateReserved": "2016-08-03T00:00:00.000Z",
        "dateUpdated": "2024-08-06T01:36:28.063Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }