Refine your search

1 vulnerability found for com.transsion.kolun.aiservice by TECNO

CVE-2024-3701 (GCVE-0-2024-3701)
Vulnerability from cvelistv5
Published
2024-04-15 07:56
Modified
2024-08-21 03:07
Severity ?
CWE
  • CWE-306 - Missing Authentication for Critical Function
Summary
The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tecno-mobile:hios:13.0.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "hios",
            "vendor": "tecno-mobile",
            "versions": [
              {
                "status": "affected",
                "version": "13.0.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-3701",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-31T15:10:10.634794Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-287",
                "description": "CWE-287 Improper Authentication",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-31T15:16:51.326Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:20:01.065Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.tecno.com/SRC/blogdetail/236?lang=en_US"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.tecno.com/SRC/securityUpdates?type=SA"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "HiOS"
          ],
          "product": "com.transsion.kolun.aiservice",
          "vendor": "TECNO",
          "versions": [
            {
              "status": "affected",
              "version": "13.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The system application (com.transsion.kolun.aiservice) component \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003edoes not perform an authentication check\u003c/span\u003e, which allows attackers to perform malicious exploitations and affect system services."
            }
          ],
          "value": "The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-21T03:07:48.011Z",
        "orgId": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea",
        "shortName": "TECNOMobile"
      },
      "references": [
        {
          "url": "https://security.tecno.com/SRC/blogdetail/236?lang=en_US"
        },
        {
          "url": "https://security.tecno.com/SRC/securityUpdates?type=SA"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper Authentication in com.transsion.kolun.aiservice",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea",
    "assignerShortName": "TECNOMobile",
    "cveId": "CVE-2024-3701",
    "datePublished": "2024-04-15T07:56:07.521Z",
    "dateReserved": "2024-04-12T08:54:13.659Z",
    "dateUpdated": "2024-08-21T03:07:48.011Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}