Refine your search
1 vulnerability found for com.transsion.kolun.aiservice by TECNO
CVE-2024-3701 (GCVE-0-2024-3701)
Vulnerability from cvelistv5
Published
2024-04-15 07:56
Modified
2024-08-21 03:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| TECNO | com.transsion.kolun.aiservice |
Version: 13.0.0 |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tecno-mobile:hios:13.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hios",
"vendor": "tecno-mobile",
"versions": [
{
"status": "affected",
"version": "13.0.0"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-3701",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-31T15:10:10.634794Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T15:16:51.326Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:20:01.065Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://security.tecno.com/SRC/blogdetail/236?lang=en_US"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.tecno.com/SRC/securityUpdates?type=SA"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"HiOS"
],
"product": "com.transsion.kolun.aiservice",
"vendor": "TECNO",
"versions": [
{
"status": "affected",
"version": "13.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The system application (com.transsion.kolun.aiservice) component \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003edoes not perform an authentication check\u003c/span\u003e, which allows attackers to perform malicious exploitations and affect system services."
}
],
"value": "The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T03:07:48.011Z",
"orgId": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea",
"shortName": "TECNOMobile"
},
"references": [
{
"url": "https://security.tecno.com/SRC/blogdetail/236?lang=en_US"
},
{
"url": "https://security.tecno.com/SRC/securityUpdates?type=SA"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Authentication in com.transsion.kolun.aiservice",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea",
"assignerShortName": "TECNOMobile",
"cveId": "CVE-2024-3701",
"datePublished": "2024-04-15T07:56:07.521Z",
"dateReserved": "2024-04-12T08:54:13.659Z",
"dateUpdated": "2024-08-21T03:07:48.011Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}