Search

Find a vulnerability

Search criteria

    30 vulnerabilities found for ac7 by tenda

    CVE-2026-4974 (GCVE-0-2026-4974)

    Vulnerability from cvelistv5 – Published: 2026-03-27 19:52 – Updated: 2026-03-31 13:54
    VLAI
    Title
    Tenda AC7 POST Request SetSysTimeCfg fromSetSysTime memory corruption
    Summary
    A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-31 13:54 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.353861 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.353861 signaturepermissions-required
    https://vuldb.com/?submit.778207 third-party-advisory
    https://lavender-bicycle-a5a.notion.site/Tenda-AC… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-4974",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-31T13:54:02.284294Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-31T13:54:19.794Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-27T19:52:50.992Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-353861 | Tenda AC7 POST Request SetSysTimeCfg fromSetSysTime memory corruption",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.353861"
            },
            {
              "name": "VDB-353861 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.353861"
            },
            {
              "name": "Submit #778207 | Tenda AC7 AC7V1.0 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.778207"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromSetSysTime-32153a41781f801c95b0f8a53eaa9a1f?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-03-27T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-03-27T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-03-27T10:01:58.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 POST Request SetSysTimeCfg fromSetSysTime memory corruption"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-4974",
        "datePublished": "2026-03-27T19:52:50.992Z",
        "dateReserved": "2026-03-27T08:56:49.008Z",
        "dateUpdated": "2026-03-31T13:54:19.794Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11586 (GCVE-0-2025-11586)

    Vulnerability from cvelistv5 – Published: 2025-10-10 21:02 – Updated: 2026-02-24 06:57
    VLAI
    Title
    Tenda AC7 setNotUpgrade stack-based overflow
    Summary
    A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-14 14:52 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11586",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-14T14:52:49.421280Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-14T14:53:00.342Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T06:57:26.088Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-327908 | Tenda AC7 setNotUpgrade stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.327908"
            },
            {
              "name": "VDB-327908 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.327908"
            },
            {
              "name": "Submit #671597 | Tenda AC7 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.671597"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/setNotUpgrade.md"
            },
            {
              "tags": [
                "exploit",
                "patch"
              ],
              "url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/setNotUpgrade.md#exploit"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-10-10T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-10-10T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-10-20T18:41:48.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 setNotUpgrade stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-11586",
        "datePublished": "2025-10-10T21:02:10.890Z",
        "dateReserved": "2025-10-10T11:53:19.717Z",
        "dateUpdated": "2026-02-24T06:57:26.088Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11528 (GCVE-0-2025-11528)

    Vulnerability from cvelistv5 – Published: 2025-10-09 03:02 – Updated: 2026-02-24 06:55
    VLAI
    Title
    Tenda AC7 saveAutoQos stack-based overflow
    Summary
    A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-09 14:28 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.327666 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.327666 signaturepermissions-required
    https://vuldb.com/?submit.669859 third-party-advisory
    https://github.com/noahze01/IoT-vulnerable/blob/m… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11528",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-09T14:28:12.203338Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-09T14:33:29.636Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/saveAutoQos.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_tu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T06:55:23.480Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-327666 | Tenda AC7 saveAutoQos stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.327666"
            },
            {
              "name": "VDB-327666 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.327666"
            },
            {
              "name": "Submit #669859 | Tenda AC7 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.669859"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/saveAutoQos.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-10-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-10-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-10-09T10:44:48.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 saveAutoQos stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-11528",
        "datePublished": "2025-10-09T03:02:07.634Z",
        "dateReserved": "2025-10-08T19:05:35.549Z",
        "dateUpdated": "2026-02-24T06:55:23.480Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11527 (GCVE-0-2025-11527)

    Vulnerability from cvelistv5 – Published: 2025-10-09 02:32 – Updated: 2026-02-24 06:55
    VLAI
    Title
    Tenda AC7 fast_setting_pppoe_set stack-based overflow
    Summary
    A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-09 13:30 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.327665 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.327665 signaturepermissions-required
    https://vuldb.com/?submit.669856 third-party-advisory
    https://github.com/noahze01/IoT-vulnerable/blob/m… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11527",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-09T13:30:03.144131Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-14T14:17:21.858Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/fast_setting_pppoe_set.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_miemie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T06:55:06.629Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-327665 | Tenda AC7 fast_setting_pppoe_set stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.327665"
            },
            {
              "name": "VDB-327665 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.327665"
            },
            {
              "name": "Submit #669856 | Tenda AC7 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.669856"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/fast_setting_pppoe_set.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-10-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-10-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-10-09T10:44:48.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 fast_setting_pppoe_set stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-11527",
        "datePublished": "2025-10-09T02:32:13.681Z",
        "dateReserved": "2025-10-08T19:05:32.826Z",
        "dateUpdated": "2026-02-24T06:55:06.629Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11526 (GCVE-0-2025-11526)

    Vulnerability from cvelistv5 – Published: 2025-10-09 02:32 – Updated: 2026-02-24 06:54
    VLAI
    Title
    Tenda AC7 WifiMacFilterSet stack-based overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-09 13:30 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.327664 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.327664 signaturepermissions-required
    https://vuldb.com/?submit.669854 third-party-advisory
    https://vuldb.com/?submit.669861 third-party-advisory
    https://github.com/noahze01/IoT-vulnerable/blob/m… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11526",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-09T13:30:48.880642Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-14T14:17:36.028Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/WifiMacFilterSet.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_ (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T06:54:51.401Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-327664 | Tenda AC7 WifiMacFilterSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.327664"
            },
            {
              "name": "VDB-327664 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.327664"
            },
            {
              "name": "Submit #669854 | Tebda AC7 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.669854"
            },
            {
              "name": "Submit #669861 | Tenda AC7 V15.03.06.44 Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.669861"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/WifiMacFilterSet.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-10-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-10-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-10-09T10:44:48.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 WifiMacFilterSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-11526",
        "datePublished": "2025-10-09T02:32:10.251Z",
        "dateReserved": "2025-10-08T19:05:30.343Z",
        "dateUpdated": "2026-02-24T06:54:51.401Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11525 (GCVE-0-2025-11525)

    Vulnerability from cvelistv5 – Published: 2025-10-09 01:32 – Updated: 2026-02-24 06:54
    VLAI
    Title
    Tenda AC7 SetUpnpCfg stack-based overflow
    Summary
    A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-09 18:13 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.327663 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.327663 signaturepermissions-required
    https://vuldb.com/?submit.669853 third-party-advisory
    https://vuldb.com/?submit.669860 third-party-advisory
    https://github.com/noahze01/IoT-vulnerable/blob/m… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11525",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-09T18:13:20.190849Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-09T18:14:22.911Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T06:54:36.276Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-327663 | Tenda AC7 SetUpnpCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.327663"
            },
            {
              "name": "VDB-327663 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.327663"
            },
            {
              "name": "Submit #669853 | Tebda AC7 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.669853"
            },
            {
              "name": "Submit #669860 | Tenda AC7 V15.03.06.44 Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.669860"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/SetUpnpCfg.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-10-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-10-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-10-09T10:44:48.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 SetUpnpCfg stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-11525",
        "datePublished": "2025-10-09T01:32:06.484Z",
        "dateReserved": "2025-10-08T19:05:27.715Z",
        "dateUpdated": "2026-02-24T06:54:36.276Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11524 (GCVE-0-2025-11524)

    Vulnerability from cvelistv5 – Published: 2025-10-09 01:02 – Updated: 2026-02-24 06:54
    VLAI
    Title
    Tenda AC7 SetDDNSCfg stack-based overflow
    Summary
    A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-09 19:17 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.327662 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.327662 signaturepermissions-required
    https://vuldb.com/?submit.669852 third-party-advisory
    https://github.com/noahze01/IoT-vulnerable/blob/m… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11524",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-09T19:17:16.686477Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-09T19:18:13.658Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T06:54:21.080Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-327662 | Tenda AC7 SetDDNSCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.327662"
            },
            {
              "name": "VDB-327662 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.327662"
            },
            {
              "name": "Submit #669852 | Tenda AC7 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.669852"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/SetDDNSCfg.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-10-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-10-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-10-09T10:44:48.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 SetDDNSCfg stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-11524",
        "datePublished": "2025-10-09T01:02:11.216Z",
        "dateReserved": "2025-10-08T19:05:24.887Z",
        "dateUpdated": "2026-02-24T06:54:21.080Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11523 (GCVE-0-2025-11523)

    Vulnerability from cvelistv5 – Published: 2025-10-09 01:02 – Updated: 2026-02-24 06:54
    VLAI
    Title
    Tenda AC7 AdvSetLanip command injection
    Summary
    A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-10-09 19:19 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.327661 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.327661 signaturepermissions-required
    https://vuldb.com/?submit.669849 third-party-advisory
    https://github.com/noahze01/IoT-vulnerable/blob/m… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11523",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-09T19:19:16.900187Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-09T19:19:43.118Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-24T06:54:08.150Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-327661 | Tenda AC7 AdvSetLanip command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.327661"
            },
            {
              "name": "VDB-327661 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.327661"
            },
            {
              "name": "Submit #669849 | Tenda AC7 V15.03.06.44 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.669849"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/AdvSetLanip.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-10-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-10-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-10-10T07:35:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 AdvSetLanip command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-11523",
        "datePublished": "2025-10-09T01:02:07.640Z",
        "dateReserved": "2025-10-08T19:05:20.207Z",
        "dateUpdated": "2026-02-24T06:54:08.150Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-9023 (GCVE-0-2025-9023)

    Vulnerability from cvelistv5 – Published: 2025-08-15 08:32 – Updated: 2025-08-15 16:01
    VLAI
    Title
    Tenda AC7/AC18 SetLEDCfg formSetSchedLed buffer overflow
    Summary
    A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-08-15 15:59 UTC
    CWE
    Assigner
    VulDB CNA
    References
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.05.19
    Affected: 15.03.06.44
    Create a notification for this product.
    Tenda AC18 Affected: 15.03.05.19
    Affected: 15.03.06.44
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9023",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-15T15:59:19.714899Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-15T16:01:28.497Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.19"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            },
            {
              "product": "AC18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.19"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "zezhifu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Dabei betrifft es die Funktion formSetSchedLed der Datei /goform/SetLEDCfg. Durch Beeinflussen des Arguments Time mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-15T08:32:07.431Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-320088 | Tenda AC7/AC18 SetLEDCfg formSetSchedLed buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.320088"
            },
            {
              "name": "VDB-320088 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.320088"
            },
            {
              "name": "Submit #629692 | Tenda AC7 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.629692"
            },
            {
              "name": "Submit #629696 | Tenda AC18 V15.03.05.19(6318) Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.629696"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/zezhifu1/cve_report/blob/main/AC7/formsetschedled.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/zezhifu1/cve_report/blob/main/AC18/formsetschedled.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-08-14T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-08-14T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-08-14T09:13:33.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7/AC18 SetLEDCfg formSetSchedLed buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-9023",
        "datePublished": "2025-08-15T08:32:07.431Z",
        "dateReserved": "2025-08-14T07:07:03.862Z",
        "dateUpdated": "2025-08-15T16:01:28.497Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-8017 (GCVE-0-2025-8017)

    Vulnerability from cvelistv5 – Published: 2025-07-22 13:32 – Updated: 2025-07-22 13:47
    VLAI
    Title
    Tenda AC7 httpd setMacFilterCfg formSetMacFilterCfg stack-based overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-07-22 13:47 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.317220 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.317220 signaturepermissions-required
    https://vuldb.com/?submit.619364 third-party-advisory
    https://github.com/Thir0th/Thir0th-CVE/blob/main/… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-8017",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-22T13:47:30.375394Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-22T13:47:43.904Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "httpd"
              ],
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "liuchangwei (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 ausgemacht. Es betrifft die Funktion formSetMacFilterCfg der Datei /goform/setMacFilterCfg der Komponente httpd. Mit der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-22T13:32:07.104Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-317220 | Tenda AC7 httpd setMacFilterCfg formSetMacFilterCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.317220"
            },
            {
              "name": "VDB-317220 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.317220"
            },
            {
              "name": "Submit #619364 | Tenda AC7  \u003c= Firmware v1.0_v15.03.06.44 RCE",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.619364"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Thir0th/Thir0th-CVE/blob/main/Tenda_AC7%20V1.0_V15.03.06.44%20has%20a%20stack%20overflow%20vulnerability%20in%20parse_macfilter_rule.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-07-22T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-07-22T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-07-22T09:21:05.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 httpd setMacFilterCfg formSetMacFilterCfg stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-8017",
        "datePublished": "2025-07-22T13:32:07.104Z",
        "dateReserved": "2025-07-22T07:15:51.690Z",
        "dateUpdated": "2025-07-22T13:47:43.904Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-5862 (GCVE-0-2025-5862)

    Vulnerability from cvelistv5 – Published: 2025-06-09 05:00 – Updated: 2025-06-09 13:23
    VLAI
    Title
    Tenda AC7 setPptpUserList formSetPPTPUserList buffer overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-09 13:23 UTC
    CWE
    Assigner
    VulDB CNA
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5862",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-09T13:23:54.451652Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-09T13:23:57.463Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetPPTPUserList-20a53a41781f806ca124cbdf99bff931"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_miemie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine kritische Schwachstelle wurde in Tenda AC7 15.03.06.44 gefunden. Es geht hierbei um die Funktion formSetPPTPUserList der Datei /goform/setPptpUserList. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-09T05:00:20.243Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-311621 | Tenda AC7 setPptpUserList formSetPPTPUserList buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.311621"
            },
            {
              "name": "VDB-311621 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.311621"
            },
            {
              "name": "Submit #591980 | Tenda AC7 V1.0 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.591980"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetPPTPUserList-20a53a41781f806ca124cbdf99bff931?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-08T15:30:36.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 setPptpUserList formSetPPTPUserList buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5862",
        "datePublished": "2025-06-09T05:00:20.243Z",
        "dateReserved": "2025-06-08T13:25:28.966Z",
        "dateUpdated": "2025-06-09T13:23:57.463Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-5861 (GCVE-0-2025-5861)

    Vulnerability from cvelistv5 – Published: 2025-06-09 04:31 – Updated: 2025-06-09 13:24
    VLAI
    Title
    Tenda AC7 AdvSetLanip fromadvsetlanip buffer overflow
    Summary
    A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-09 13:24 UTC
    CWE
    Assigner
    VulDB CNA
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5861",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-09T13:24:25.807553Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-09T13:24:28.589Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromadvsetlanip-20a53a41781f80038f4fc4b9d927eb9a"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_backup (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "In Tenda AC7 15.03.06.44 wurde eine kritische Schwachstelle gefunden. Es geht um die Funktion fromadvsetlanip der Datei /goform/AdvSetLanip. Dank Manipulation des Arguments lanMask mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-09T04:31:06.939Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-311620 | Tenda AC7 AdvSetLanip fromadvsetlanip buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.311620"
            },
            {
              "name": "VDB-311620 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.311620"
            },
            {
              "name": "Submit #591960 | Tenda AC7 V1.0 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.591960"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromadvsetlanip-20a53a41781f80038f4fc4b9d927eb9a?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-08T15:30:34.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 AdvSetLanip fromadvsetlanip buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-5861",
        "datePublished": "2025-06-09T04:31:06.939Z",
        "dateReserved": "2025-06-08T13:25:26.572Z",
        "dateUpdated": "2025-06-09T13:24:28.589Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-4810 (GCVE-0-2025-4810)

    Vulnerability from cvelistv5 – Published: 2025-05-16 20:31 – Updated: 2025-05-17 02:25
    VLAI
    Title
    Tenda AC7 SetRebootTimer formSetRebootTimer stack-based overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-17 02:24 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.309265 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.309265 signaturepermissions-required
    https://vuldb.com/?submit.573643 third-party-advisory
    https://lavender-bicycle-a5a.notion.site/Tenda-AC… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-4810",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-17T02:24:15.430149Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-17T02:25:49.517Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_tu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "In Tenda AC7 15.03.06.44 wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion formSetRebootTimer der Datei /goform/SetRebootTimer. Dank der Manipulation des Arguments reboot_time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-16T20:31:06.542Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-309265 | Tenda AC7 SetRebootTimer formSetRebootTimer stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.309265"
            },
            {
              "name": "VDB-309265 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.309265"
            },
            {
              "name": "Submit #573643 | Tenda AC7 V1.0 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.573643"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetRebootTimer-1ed53a41781f80f78851c1c9dfc4f216?pvs=4"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-05-16T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-05-16T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-05-16T10:49:18.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 SetRebootTimer formSetRebootTimer stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-4810",
        "datePublished": "2025-05-16T20:31:06.542Z",
        "dateReserved": "2025-05-16T08:44:12.481Z",
        "dateUpdated": "2025-05-17T02:25:49.517Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-4809 (GCVE-0-2025-4809)

    Vulnerability from cvelistv5 – Published: 2025-05-16 20:00 – Updated: 2025-05-17 02:29
    VLAI
    Title
    Tenda AC7 setMacFilterCfg fromSafeSetMacFilter stack-based overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-17 02:29 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.309264 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.309264 signaturepermissions-required
    https://vuldb.com/?submit.573642 third-party-advisory
    https://lavender-bicycle-a5a.notion.site/Tenda-AC… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-4809",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-17T02:29:39.364436Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-17T02:29:55.165Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_miemie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 ausgemacht. Betroffen hiervon ist die Funktion fromSafeSetMacFilter der Datei /goform/setMacFilterCfg. Durch Beeinflussen des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-16T20:00:14.307Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-309264 | Tenda AC7 setMacFilterCfg fromSafeSetMacFilter stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.309264"
            },
            {
              "name": "VDB-309264 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.309264"
            },
            {
              "name": "Submit #573642 | Tenda AC7 V1.0 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.573642"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromSafeSetMacFilter-1ed53a41781f80cbbf13c8d4cc405ed1?pvs=4"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-05-16T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-05-16T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-05-16T10:49:17.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 setMacFilterCfg fromSafeSetMacFilter stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-4809",
        "datePublished": "2025-05-16T20:00:14.307Z",
        "dateReserved": "2025-05-16T08:44:09.877Z",
        "dateUpdated": "2025-05-17T02:29:55.165Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3346 (GCVE-0-2025-3346)

    Vulnerability from cvelistv5 – Published: 2025-04-07 09:31 – Updated: 2025-04-07 16:11
    VLAI
    Title
    Tenda AC7 SetPptpServerCfg formSetPPTPServer buffer overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-07 16:11 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.303560 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.303560 signaturepermissions-required
    https://vuldb.com/?submit.551927 third-party-advisory
    https://github.com/CH13hh/tmp_store_cc/blob/main/… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3346",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-07T16:11:19.829467Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-07T16:11:42.026Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "CH13hh (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine kritische Schwachstelle wurde in Tenda AC7 15.03.06.44 ausgemacht. Davon betroffen ist die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Durch Manipulation des Arguments pptp_server_start_ip/pptp_server_end_ip mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-07T09:31:08.740Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-303560 | Tenda AC7 SetPptpServerCfg formSetPPTPServer buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.303560"
            },
            {
              "name": "VDB-303560 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.303560"
            },
            {
              "name": "Submit #551927 | Shenzhen Tenda Technology Co.,Ltd. AC7 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.551927"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/CH13hh/tmp_store_cc/blob/main/AC7formSetPPTPServer/formSetPPTPServer.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-04-06T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-04-06T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-04-06T16:43:57.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 SetPptpServerCfg formSetPPTPServer buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-3346",
        "datePublished": "2025-04-07T09:31:08.740Z",
        "dateReserved": "2025-04-06T14:38:54.203Z",
        "dateUpdated": "2025-04-07T16:11:42.026Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-1851 (GCVE-0-2025-1851)

    Vulnerability from cvelistv5 – Published: 2025-03-03 05:00 – Updated: 2025-03-03 17:19
    VLAI
    Title
    Tenda AC7 SetFirewallCfg formSetFirewallCfg stack-based overflow
    Summary
    A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-03-03 17:19 UTC
    CWE
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.298119 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.298119 signaturepermissions-required
    https://vuldb.com/?submit.505271 third-party-advisory
    https://github.com/Raining-101/IOT_cve/blob/main/… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.0
    Affected: 15.03.06.1
    Affected: 15.03.06.2
    Affected: 15.03.06.3
    Affected: 15.03.06.4
    Affected: 15.03.06.5
    Affected: 15.03.06.6
    Affected: 15.03.06.7
    Affected: 15.03.06.8
    Affected: 15.03.06.9
    Affected: 15.03.06.10
    Affected: 15.03.06.11
    Affected: 15.03.06.12
    Affected: 15.03.06.13
    Affected: 15.03.06.14
    Affected: 15.03.06.15
    Affected: 15.03.06.16
    Affected: 15.03.06.17
    Affected: 15.03.06.18
    Affected: 15.03.06.19
    Affected: 15.03.06.20
    Affected: 15.03.06.21
    Affected: 15.03.06.22
    Affected: 15.03.06.23
    Affected: 15.03.06.24
    Affected: 15.03.06.25
    Affected: 15.03.06.26
    Affected: 15.03.06.27
    Affected: 15.03.06.28
    Affected: 15.03.06.29
    Affected: 15.03.06.30
    Affected: 15.03.06.31
    Affected: 15.03.06.32
    Affected: 15.03.06.33
    Affected: 15.03.06.34
    Affected: 15.03.06.35
    Affected: 15.03.06.36
    Affected: 15.03.06.37
    Affected: 15.03.06.38
    Affected: 15.03.06.39
    Affected: 15.03.06.40
    Affected: 15.03.06.41
    Affected: 15.03.06.42
    Affected: 15.03.06.43
    Affected: 15.03.06.44
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-1851",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-03T17:19:37.187929Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-03T17:19:41.764Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/Raining-101/IOT_cve/blob/main/ac7_V15.03.06.44_SetFirewallCfg.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.0"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.1"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.2"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.3"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.4"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.5"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.6"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.7"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.8"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.9"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.10"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.11"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.12"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.13"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.14"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.15"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.16"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.17"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.18"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.19"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.20"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.21"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.22"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.23"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.24"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.25"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.26"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.27"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.28"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.29"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.30"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.31"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.32"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.33"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.34"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.35"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.36"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.37"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.38"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.39"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.40"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.41"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.42"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.43"
                },
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Raining101 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 bis 15.03.06.44 gefunden. Betroffen hiervon ist die Funktion formSetFirewallCfg der Datei /goform/SetFirewallCfg. Durch Manipulieren des Arguments firewallEn mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-03T05:00:07.574Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-298119 | Tenda AC7 SetFirewallCfg formSetFirewallCfg stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.298119"
            },
            {
              "name": "VDB-298119 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.298119"
            },
            {
              "name": "Submit #505271 | Tenda ac7 V15.03.06.44 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.505271"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Raining-101/IOT_cve/blob/main/ac7_V15.03.06.44_SetFirewallCfg.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-03-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-03-02T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-03-02T21:09:38.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 SetFirewallCfg formSetFirewallCfg stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-1851",
        "datePublished": "2025-03-03T05:00:07.574Z",
        "dateReserved": "2025-03-02T20:04:35.439Z",
        "dateUpdated": "2025-03-03T17:19:41.764Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-10280 (GCVE-0-2024-10280)

    Vulnerability from cvelistv5 – Published: 2024-10-23 13:31 – Updated: 2024-10-23 17:41
    VLAI
    Title
    Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference
    Summary
    A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-23 17:28 UTC
    CWE
    • CWE-476 - NULL Pointer Dereference
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.281555 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.281555 signaturepermissions-required
    https://vuldb.com/?submit.426417 third-party-advisory
    https://github.com/JohenanLi/router_vuls/blob/mai… exploit
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda AC6 Affected: 20241022
    Create a notification for this product.
    Tenda AC7 Affected: 20241022
    Create a notification for this product.
    Tenda AC8 Affected: 20241022
    Create a notification for this product.
    Tenda AC9 Affected: 20241022
    Create a notification for this product.
    Tenda AC10 Affected: 20241022
    Create a notification for this product.
    Tenda AC10U Affected: 20241022
    Create a notification for this product.
    Tenda AC15 Affected: 20241022
    Create a notification for this product.
    Tenda AC18 Affected: 20241022
    Create a notification for this product.
    Tenda AC500 Affected: 20241022
    Create a notification for this product.
    Tenda AC1206 Affected: 20241022
    Create a notification for this product.
    tenda ac6_firmware Affected: 15.03.06.23
        cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac8_firmware Affected: 16.03.34.06
        cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac8_firmware Affected: 16.03.34.09
        cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac10_firmware Affected: 16.03.48.23
    Affected: 16.03.48.19
    Affected: 16.03.48.20
    Affected: 16.03.48.13
        cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac1206_firmware Affected: 15.03.06.23
        cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac9_firmware Affected: 15.03.06.42
    Affected: 15.03.05.19\(6318_\)
    Affected: 15.03.05.14
    Affected: 15.03.2.13
        cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac18_firmware Affected: 15.03.05.05
        cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac18_firmware Affected: 15.03.05.19\(6318\)
        cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\(6318\):*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac500_firmware Affected: 2.0.1.9\(1307\)
        cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\(1307\):*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac500_firmware Affected: 1.0.0.16
        cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac500_firmware Affected: 1.0.0.14
        cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac10u_firmware Affected: 15.03.06.48
        cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac10u_firmware Affected: 15.03.06.49
        cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac7_firmware Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac15_firmware Affected: 15.03.05.18
        cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*
    Create a notification for this product.
    tenda ac15_firmware Affected: 15.03.05.19
        cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac6_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.23"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac8_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "16.03.34.06"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac8_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "16.03.34.09"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac10_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "16.03.48.23"
                  },
                  {
                    "status": "affected",
                    "version": "16.03.48.19"
                  },
                  {
                    "status": "affected",
                    "version": "16.03.48.20"
                  },
                  {
                    "status": "affected",
                    "version": "16.03.48.13"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac1206_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.23"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac9_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.42"
                  },
                  {
                    "status": "affected",
                    "version": "15.03.05.19\\(6318_\\)"
                  },
                  {
                    "status": "affected",
                    "version": "15.03.05.14"
                  },
                  {
                    "status": "affected",
                    "version": "15.03.2.13"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac18_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.05.05"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac18_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.05.19\\(6318\\)"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac500_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.0.1.9\\(1307\\)"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac500_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.16"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac500_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.0.0.14"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac10u_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.48"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac10u_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.49"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac15_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.05.18"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac15_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.05.19"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-10280",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-23T17:28:19.760214Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-23T17:41:57.370Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC6",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20241022"
                }
              ]
            },
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20241022"
                }
              ]
            },
            {
              "product": "AC8",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20241022"
                }
              ]
            },
            {
              "product": "AC9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20241022"
                }
              ]
            },
            {
              "product": "AC10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20241022"
                }
              ]
            },
            {
              "product": "AC10U",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20241022"
                }
              ]
            },
            {
              "product": "AC15",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20241022"
                }
              ]
            },
            {
              "product": "AC18",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20241022"
                }
              ]
            },
            {
              "product": "AC500",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20241022"
                }
              ]
            },
            {
              "product": "AC1206",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "20241022"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "minipython (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.8,
                "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "NULL Pointer Dereference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-23T13:31:07.315Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.281555"
            },
            {
              "name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.281555"
            },
            {
              "name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.426417"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-10-23T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-10-23T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-10-23T08:07:55.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-10280",
        "datePublished": "2024-10-23T13:31:07.315Z",
        "dateReserved": "2024-10-23T06:02:03.363Z",
        "dateUpdated": "2024-10-23T17:41:57.370Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2903 (GCVE-0-2024-2903)

    Vulnerability from cvelistv5 – Published: 2024-03-26 20:31 – Updated: 2024-08-15 15:54
    VLAI
    Title
    Tenda AC7 GetParentControlInfo stack-based overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-15 15:52 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257946 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257946 signaturepermissions-required
    https://vuldb.com/?submit.300452 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7 Affected: 15.03.06.44
        cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.219Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257946 | Tenda AC7 GetParentControlInfo stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257946"
              },
              {
                "name": "VDB-257946 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257946"
              },
              {
                "name": "Submit #300452 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300452"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2903",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-15T15:52:57.072819Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-15T15:54:17.573Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 ausgemacht. Hiervon betroffen ist die Funktion GetParentControlInfo der Datei /goform/GetParentControlInfo. Durch das Manipulieren des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T20:31:04.040Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257946 | Tenda AC7 GetParentControlInfo stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257946"
            },
            {
              "name": "VDB-257946 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257946"
            },
            {
              "name": "Submit #300452 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300452"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:31:50.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 GetParentControlInfo stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2903",
        "datePublished": "2024-03-26T20:31:04.040Z",
        "dateReserved": "2024-03-26T09:26:47.360Z",
        "dateUpdated": "2024-08-15T15:54:17.573Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2902 (GCVE-0-2024-2902)

    Vulnerability from cvelistv5 – Published: 2024-03-26 20:00 – Updated: 2024-08-12 13:35
    VLAI
    Title
    Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-04-15 19:37 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257945 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257945 signaturepermissions-required
    https://vuldb.com/?submit.300449 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7_firmware Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.155Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257945 | Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257945"
              },
              {
                "name": "VDB-257945 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257945"
              },
              {
                "name": "Submit #300449 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300449"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2902",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-15T19:37:20.952602Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-12T13:35:50.633Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine kritische Schwachstelle wurde in Tenda AC7 15.03.06.44 gefunden. Davon betroffen ist die Funktion fromSetWifiGusetBasic der Datei /goform/WifiGuestSet. Mittels Manipulieren des Arguments shareSpeed mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T20:00:08.534Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257945 | Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257945"
            },
            {
              "name": "VDB-257945 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257945"
            },
            {
              "name": "Submit #300449 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300449"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:31:44.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2902",
        "datePublished": "2024-03-26T20:00:08.534Z",
        "dateReserved": "2024-03-26T09:26:38.442Z",
        "dateUpdated": "2024-08-12T13:35:50.633Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2901 (GCVE-0-2024-2901)

    Vulnerability from cvelistv5 – Published: 2024-03-26 20:00 – Updated: 2024-08-29 19:09
    VLAI
    Title
    Tenda AC7 openSchedWifi setSchedWifi stack-based overflow
    Summary
    A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-20 20:50 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257944 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257944 signaturepermissions-required
    https://vuldb.com/?submit.300367 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7 Affected: 15.03.06.44
        cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.161Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257944 | Tenda AC7 openSchedWifi setSchedWifi stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257944"
              },
              {
                "name": "VDB-257944 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257944"
              },
              {
                "name": "Submit #300367 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300367"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2901",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-20T20:50:19.200809Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-29T19:09:39.749Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda AC7 15.03.06.44 wurde eine kritische Schwachstelle gefunden. Hierbei betrifft es die Funktion setSchedWifi der Datei /goform/openSchedWifi. Mittels dem Manipulieren des Arguments schedEndTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T20:00:06.887Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257944 | Tenda AC7 openSchedWifi setSchedWifi stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257944"
            },
            {
              "name": "VDB-257944 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257944"
            },
            {
              "name": "Submit #300367 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300367"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:31:39.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 openSchedWifi setSchedWifi stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2901",
        "datePublished": "2024-03-26T20:00:06.887Z",
        "dateReserved": "2024-03-26T09:26:24.727Z",
        "dateUpdated": "2024-08-29T19:09:39.749Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2900 (GCVE-0-2024-2900)

    Vulnerability from cvelistv5 – Published: 2024-03-26 19:31 – Updated: 2024-08-01 19:25
    VLAI
    Title
    Tenda AC7 saveParentControlInfo stack-based overflow
    Summary
    A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-01 18:06 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257943 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257943 signaturepermissions-required
    https://vuldb.com/?submit.300364 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7_firmware Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2900",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-01T18:06:26.520903Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:08:23.914Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.144Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257943 | Tenda AC7 saveParentControlInfo stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257943"
              },
              {
                "name": "VDB-257943 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257943"
              },
              {
                "name": "Submit #300364 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300364"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 gefunden. Dabei betrifft es die Funktion saveParentControlInfo der Datei /goform/saveParentControlInfo. Durch Manipulation des Arguments deviceId/time/urls mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T19:31:04.524Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257943 | Tenda AC7 saveParentControlInfo stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257943"
            },
            {
              "name": "VDB-257943 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257943"
            },
            {
              "name": "Submit #300364 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300364"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:31:26.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 saveParentControlInfo stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2900",
        "datePublished": "2024-03-26T19:31:04.524Z",
        "dateReserved": "2024-03-26T09:26:11.290Z",
        "dateUpdated": "2024-08-01T19:25:42.144Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2899 (GCVE-0-2024-2899)

    Vulnerability from cvelistv5 – Published: 2024-03-26 19:00 – Updated: 2025-04-10 18:28
    VLAI
    Title
    Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow
    Summary
    A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-16 17:43 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257942 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257942 signaturepermissions-required
    https://vuldb.com/?submit.300362 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7 Affected: 15.03.06.44
        cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2899",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-16T17:43:12.540684Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-10T18:28:47.028Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.223Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257942 | Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257942"
              },
              {
                "name": "VDB-257942 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257942"
              },
              {
                "name": "Submit #300362 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300362"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWirelessRepeat.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine kritische Schwachstelle wurde in Tenda AC7 15.03.06.44 entdeckt. Dies betrifft die Funktion fromSetWirelessRepeat der Datei /goform/WifiExtraSet. Durch die Manipulation des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T19:00:07.170Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257942 | Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257942"
            },
            {
              "name": "VDB-257942 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257942"
            },
            {
              "name": "Submit #300362 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300362"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWirelessRepeat.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:31:13.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2899",
        "datePublished": "2024-03-26T19:00:07.170Z",
        "dateReserved": "2024-03-26T09:26:06.184Z",
        "dateUpdated": "2025-04-10T18:28:47.028Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2898 (GCVE-0-2024-2898)

    Vulnerability from cvelistv5 – Published: 2024-03-26 18:31 – Updated: 2024-08-01 19:25
    VLAI
    Title
    Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow
    Summary
    A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-16 21:02 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257941 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257941 signaturepermissions-required
    https://vuldb.com/?submit.300361 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7_firmware Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2898",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-16T21:02:27.145376Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-16T21:03:00.476Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.160Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257941 | Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257941"
              },
              {
                "name": "VDB-257941 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257941"
              },
              {
                "name": "Submit #300361 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300361"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetRouteStatic.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda AC7 15.03.06.44 wurde eine kritische Schwachstelle entdeckt. Das betrifft die Funktion fromSetRouteStatic der Datei /goform/SetStaticRouteCfg. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T18:31:05.622Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257941 | Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257941"
            },
            {
              "name": "VDB-257941 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257941"
            },
            {
              "name": "Submit #300361 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300361"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetRouteStatic.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:31:07.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2898",
        "datePublished": "2024-03-26T18:31:05.622Z",
        "dateReserved": "2024-03-26T09:26:00.834Z",
        "dateUpdated": "2024-08-01T19:25:42.160Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2897 (GCVE-0-2024-2897)

    Vulnerability from cvelistv5 – Published: 2024-03-26 18:31 – Updated: 2024-08-01 19:25
    VLAI
    Title
    Tenda AC7 WriteFacMac formWriteFacMac os command injection
    Summary
    A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-04-15 14:30 UTC
    CWE
    • CWE-78 - OS Command Injection
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257940 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257940 signaturepermissions-required
    https://vuldb.com/?submit.300360 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2897",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-15T14:30:45.791519Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:30:55.078Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.169Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257940 | Tenda AC7 WriteFacMac formWriteFacMac os command injection",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257940"
              },
              {
                "name": "VDB-257940 | CTI Indicators (IOB, IOC, TTP, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257940"
              },
              {
                "name": "Submit #300360 | Tenda AC7 V1.0 V15.03.06.44 command injection",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300360"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWriteFacMac.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 entdeckt. Es betrifft die Funktion formWriteFacMac der Datei /goform/WriteFacMac. Dank Manipulation des Arguments mac mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T18:31:04.287Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257940 | Tenda AC7 WriteFacMac formWriteFacMac os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257940"
            },
            {
              "name": "VDB-257940 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257940"
            },
            {
              "name": "Submit #300360 | Tenda AC7 V1.0 V15.03.06.44 command injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300360"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWriteFacMac.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:31:02.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 WriteFacMac formWriteFacMac os command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2897",
        "datePublished": "2024-03-26T18:31:04.287Z",
        "dateReserved": "2024-03-26T09:25:55.503Z",
        "dateUpdated": "2024-08-01T19:25:42.169Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2896 (GCVE-0-2024-2896)

    Vulnerability from cvelistv5 – Published: 2024-03-26 18:00 – Updated: 2024-08-01 19:25
    VLAI
    Title
    Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-26 19:44 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257939 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257939 signaturepermissions-required
    https://vuldb.com/?submit.300359 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7 Affected: 15.03.06.44
        cpe:2.3:h:tenda:ac7:15.03.06.44:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:ac7:15.03.06.44:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2896",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-26T19:44:29.669077Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-26T19:49:54.294Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.175Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257939 | Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257939"
              },
              {
                "name": "VDB-257939 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257939"
              },
              {
                "name": "Submit #300359 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300359"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsStart.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda AC7 15.03.06.44 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formWifiWpsStart der Datei /goform/WifiWpsStart. Dank der Manipulation des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T18:00:06.676Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257939 | Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257939"
            },
            {
              "name": "VDB-257939 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257939"
            },
            {
              "name": "Submit #300359 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300359"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsStart.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:30:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2896",
        "datePublished": "2024-03-26T18:00:06.676Z",
        "dateReserved": "2024-03-26T09:25:50.265Z",
        "dateUpdated": "2024-08-01T19:25:42.175Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2895 (GCVE-0-2024-2895)

    Vulnerability from cvelistv5 – Published: 2024-03-26 17:31 – Updated: 2024-08-01 19:25
    VLAI
    Title
    Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-05 19:51 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257938 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257938 signaturepermissions-required
    https://vuldb.com/?submit.300358 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7_firmware Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2895",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-05T19:51:36.570635Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-05T19:52:13.147Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.160Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257938 | Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257938"
              },
              {
                "name": "VDB-257938 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257938"
              },
              {
                "name": "Submit #300358 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300358"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda AC7 15.03.06.44 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formWifiWpsOOB der Datei /goform/WifiWpsOOB. Durch Beeinflussen des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T17:31:04.304Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257938 | Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257938"
            },
            {
              "name": "VDB-257938 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257938"
            },
            {
              "name": "Submit #300358 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300358"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:30:51.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2895",
        "datePublished": "2024-03-26T17:31:04.304Z",
        "dateReserved": "2024-03-26T09:25:44.223Z",
        "dateUpdated": "2024-08-01T19:25:42.160Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2894 (GCVE-0-2024-2894)

    Vulnerability from cvelistv5 – Published: 2024-03-26 17:00 – Updated: 2024-08-15 18:17
    VLAI
    Title
    Tenda AC7 SetNetControlList formSetQosBand stack-based overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-15 18:15 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257937 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257937 signaturepermissions-required
    https://vuldb.com/?submit.300357 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7_firmware Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.177Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257937 | Tenda AC7 SetNetControlList formSetQosBand stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257937"
              },
              {
                "name": "VDB-257937 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257937"
              },
              {
                "name": "Submit #300357 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300357"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2894",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-15T18:15:35.740727Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-15T18:17:10.564Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine Schwachstelle in Tenda AC7 15.03.06.44 ausgemacht. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion formSetQosBand der Datei /goform/SetNetControlList. Durch das Beeinflussen des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T17:00:07.831Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257937 | Tenda AC7 SetNetControlList formSetQosBand stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257937"
            },
            {
              "name": "VDB-257937 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257937"
            },
            {
              "name": "Submit #300357 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300357"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:30:46.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 SetNetControlList formSetQosBand stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2894",
        "datePublished": "2024-03-26T17:00:07.831Z",
        "dateReserved": "2024-03-26T09:25:39.103Z",
        "dateUpdated": "2024-08-15T18:17:10.564Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2893 (GCVE-0-2024-2893)

    Vulnerability from cvelistv5 – Published: 2024-03-26 16:31 – Updated: 2024-08-12 13:37
    VLAI
    Title
    Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow
    Summary
    A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-04-15 19:38 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257936 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257936 signaturepermissions-required
    https://vuldb.com/?submit.300356 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7_firmware Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.172Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257936 | Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257936"
              },
              {
                "name": "VDB-257936 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257936"
              },
              {
                "name": "Submit #300356 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300356"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetDeviceName_devName.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2893",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-15T19:38:25.903653Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-12T13:37:09.831Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Tenda AC7 15.03.06.44 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Durch Manipulieren des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T16:31:04.545Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257936 | Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257936"
            },
            {
              "name": "VDB-257936 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257936"
            },
            {
              "name": "Submit #300356 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300356"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetDeviceName_devName.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:30:40.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2893",
        "datePublished": "2024-03-26T16:31:04.545Z",
        "dateReserved": "2024-03-26T09:25:34.223Z",
        "dateUpdated": "2024-08-12T13:37:09.831Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2892 (GCVE-0-2024-2892)

    Vulnerability from cvelistv5 – Published: 2024-03-26 16:00 – Updated: 2024-08-29 19:09
    VLAI
    Title
    Tenda AC7 setcfm formSetCfm stack-based overflow
    Summary
    A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-20 20:56 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257935 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257935 signaturepermissions-required
    https://vuldb.com/?submit.300355 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7 Affected: 15.03.06.44
        cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.154Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257935 | Tenda AC7 setcfm formSetCfm stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257935"
              },
              {
                "name": "VDB-257935 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257935"
              },
              {
                "name": "Submit #300355 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300355"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetCfm.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2892",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-20T20:56:27.735043Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-29T19:09:59.106Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_miemie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda AC7 15.03.06.44 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um die Funktion formSetCfm der Datei /goform/setcfm. Durch das Manipulieren des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T16:00:05.583Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257935 | Tenda AC7 setcfm formSetCfm stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257935"
            },
            {
              "name": "VDB-257935 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257935"
            },
            {
              "name": "Submit #300355 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300355"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetCfm.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:30:35.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 setcfm formSetCfm stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2892",
        "datePublished": "2024-03-26T16:00:05.583Z",
        "dateReserved": "2024-03-26T09:25:27.601Z",
        "dateUpdated": "2024-08-29T19:09:59.106Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-2891 (GCVE-0-2024-2891)

    Vulnerability from cvelistv5 – Published: 2024-03-26 14:00 – Updated: 2024-08-01 19:25
    VLAI
    Title
    Tenda AC7 QuickIndex formQuickIndex stack-based overflow
    Summary
    A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-01 18:36 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    VulDB CNA
    References
    URL Tags
    https://vuldb.com/?id.257934 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.257934 signaturepermissions-required
    https://vuldb.com/?submit.300354 third-party-advisory
    https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
    Impacted products
    Vendor Product Version
    Tenda AC7 Affected: 15.03.06.44
    Create a notification for this product.
    tenda ac7_firmware Affected: 15.03.06.44
        cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac7_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.44"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2891",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-01T18:36:55.001433Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:37:43.390Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:42.202Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257934 | Tenda AC7 QuickIndex formQuickIndex stack-based overflow",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257934"
              },
              {
                "name": "VDB-257934 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257934"
              },
              {
                "name": "Submit #300354 | Tenda AC7 AC7V1.0 V15.03.06.44 buffer overflow",
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?submit.300354"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC7",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.44"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_miemie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine Schwachstelle in Tenda AC7 15.03.06.44 gefunden. Sie wurde als kritisch eingestuft. Betroffen hiervon ist die Funktion formQuickIndex der Datei /goform/QuickIndex. Mittels Manipulieren des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-26T14:00:07.492Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257934 | Tenda AC7 QuickIndex formQuickIndex stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257934"
            },
            {
              "name": "VDB-257934 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257934"
            },
            {
              "name": "Submit #300354 | Tenda AC7 AC7V1.0 V15.03.06.44 buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.300354"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-26T10:30:30.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC7 QuickIndex formQuickIndex stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2891",
        "datePublished": "2024-03-26T14:00:07.492Z",
        "dateReserved": "2024-03-26T09:25:25.245Z",
        "dateUpdated": "2024-08-01T19:25:42.202Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }