Refine your search
1 vulnerability found for X300 by TOZED
CVE-2026-108576 (GCVE-0-2026-108576)
Vulnerability from cvelistv5
Published
2026-10-11 12:15
Modified
2026-10-13 19:59
Severity ?
10.0 (Critical) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/RC:R
10.0 (Critical) - CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/RC:R
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/RC:R
10.0 (Critical) - CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/RC:R
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in TOZED X300 up to 6.01.3. This vulnerability affects the function process_ping of the component IPPingDiagnostics Handler. The manipulation of the argument Host results in os command injection. The attack can be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-108576",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-13T19:59:03.698604Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-13T19:59:21.894Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:tozed:x300:*:*:*:*:*:*:*:*"
],
"modules": [
"IPPingDiagnostics Handler"
],
"product": "X300",
"vendor": "TOZED",
"versions": [
{
"status": "affected",
"version": "6.01.0"
},
{
"status": "affected",
"version": "6.01.1"
},
{
"status": "affected",
"version": "6.01.2"
},
{
"status": "affected",
"version": "6.01.3"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "danish1162 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in TOZED X300 up to 6.01.3. This vulnerability affects the function process_ping of the component IPPingDiagnostics Handler. The manipulation of the argument Host results in os command injection. The attack can be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 10,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-11T12:15:13.822Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-416233 | TOZED X300 IPPingDiagnostics process_ping os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/416233"
},
{
"name": "VDB-416233 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/416233/cti"
},
{
"name": "CVE-2026-108576 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-108576"
},
{
"name": "Submit #956290 | Tozed Kangwei ZLT X300 6.01.3 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/956290"
},
{
"tags": [
"related"
],
"url": "https://github.com/danish1162/CVE-2026-2035703-x300/security/advisories/GHSA-qcpp-vfr2-v242"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-10-10T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-10-10T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-10T17:47:19.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOZED X300 IPPingDiagnostics process_ping os command injection",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-108576",
"datePublished": "2026-10-11T12:15:13.822Z",
"dateReserved": "2026-10-10T15:41:51.290Z",
"dateUpdated": "2026-10-13T19:59:21.894Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}