Search

Find a vulnerability

Search criteria

    1 vulnerability found for WTV776-HB6035 Web Interface by Siemens

    CVE-2026-89207 (GCVE-0-2026-89207)

    Vulnerability from cvelistv5 – Published: 2026-09-16 07:59 – Updated: 2026-09-16 18:13
    VLAI
    Summary
    A vulnerability has been identified in WTV676-HB6035 Web Interface (All versions < V3.94), WTV776-HB6035 Web Interface (All versions < V4.17). Affected devices do not properly validate input received from backend services. This could allow an unauthenticated remote attacker to force the device into protection mode, which results in losing remote connectivity functions (Web Access).
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-16 18:13 UTC
    CWE
    • CWE-1287 - Improper Validation of Specified Type of Input
    Assigner
    siemens CNA
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-89207",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-16T18:13:09.211468Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-16T18:13:23.189Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "WTV676-HB6035 Web Interface",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.94",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "WTV776-HB6035 Web Interface",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.17",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in WTV676-HB6035 Web Interface (All versions \u003c V3.94), WTV776-HB6035 Web Interface (All versions \u003c V4.17). Affected devices do not properly validate input received from backend services.\r\nThis could allow an unauthenticated remote attacker to force the device into protection mode, which results in losing remote connectivity functions (Web Access)."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1287",
                  "description": "CWE-1287: Improper Validation of Specified Type of Input",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-16T07:59:08.075Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-823812.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-89207",
        "datePublished": "2026-09-16T07:59:08.075Z",
        "dateReserved": "2026-09-11T07:45:20.919Z",
        "dateUpdated": "2026-09-16T18:13:23.189Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }