Refine your search
1 vulnerability found for WF2419 by Netis
CVE-2025-9119 (GCVE-0-2025-9119)
Vulnerability from cvelistv5
Published
2025-08-18 20:32
Modified
2025-08-18 20:40
Severity ?
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was determined in Netis WF2419 1.2.29433. This vulnerability affects unknown code of the file /index.htm of the component Wireless Settings Page. This manipulation of the argument SSID with the input <img/src/onerror=prompt(8)> causes cross site scripting. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9119",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-18T20:40:22.687014Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-18T20:40:32.927Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Wireless Settings Page"
],
"product": "WF2419",
"vendor": "Netis",
"versions": [
{
"status": "affected",
"version": "1.2.29433"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Fergod (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Netis WF2419 1.2.29433. This vulnerability affects unknown code of the file /index.htm of the component Wireless Settings Page. This manipulation of the argument SSID with the input \u003cimg/src/onerror=prompt(8)\u003e causes cross site scripting. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Netis WF2419 1.2.29433 gefunden. Dies betrifft einen unbekannten Teil der Datei /index.htm der Komponente Wireless Settings Page. Durch Beeinflussen des Arguments SSID mit der Eingabe \u003cimg/src/onerror=prompt(8)\u003e mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-18T20:32:05.688Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-320456 | Netis WF2419 Wireless Settings index.htm cross site scripting",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.320456"
},
{
"name": "VDB-320456 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.320456"
},
{
"name": "Submit #628410 | Netis WF2419 V1.2.29433 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.628410"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-08-18T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-08-18T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-08-18T17:20:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netis WF2419 Wireless Settings index.htm cross site scripting"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-9119",
"datePublished": "2025-08-18T20:32:05.688Z",
"dateReserved": "2025-08-18T15:15:51.402Z",
"dateUpdated": "2025-08-18T20:40:32.927Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}