Refine your search

2 vulnerabilities found for W18E by Tenda

CVE-2026-118238 (GCVE-0-2026-118238)
Vulnerability from cvelistv5
Published
2026-10-30 15:08
Modified
2026-10-30 17:07
Summary
The Tenda W18E web management server is vulnerable to OS command injection via the "diagnose" packet-capture feature due to improper validation of JSON fields. An authenticated user can inject shell metacharacters into the protocol or targetDevice fields, which are later concatenated into a tcpdump command and executed with root privileges. This vulnerability can be exploited without authentication if the device is in a factory-reset state.
Impacted products
Vendor Product Version
Tenda W18E Version: V16.01.0.20
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.2,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2026-118238",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-30T17:07:03.133377Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-78",
                "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-30T17:07:06.917Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W18E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "V16.01.0.20"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Tenda W18E web management server is vulnerable to OS command injection via the \"diagnose\" packet-capture feature due to improper validation of JSON fields. An authenticated user can inject shell metacharacters into the protocol or targetDevice fields, which are later concatenated into a tcpdump command and executed with root privileges. This vulnerability can be exploited without authentication if the device is in a factory-reset state."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-30T15:08:41.752Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "url": "https://cushz.github.io/en/exploit-development/2026/10/27/hacking-routers-for-fun-and-not-profit.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2026-118238",
      "x_generator": {
        "engine": "VINCE 3.0.52",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2026-118238"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2026-118238",
    "datePublished": "2026-10-30T15:08:41.752Z",
    "dateReserved": "2026-10-27T19:49:03.088Z",
    "dateUpdated": "2026-10-30T17:07:06.917Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-3203 (GCVE-0-2025-3203)
Vulnerability from cvelistv5
Published
2025-04-04 02:31
Modified
2025-04-04 15:45
CWE
Summary
A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the argument Password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
Impacted products
Vendor Product Version
Tenda W18E Version: 16.01.0.11
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3203",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-04T15:44:52.340781Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-04T15:45:15.623Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/ZIKH26/tmp_store_reports/blob/main/tenda-w18e.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W18E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.01.0.11"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "ZIKH26 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the argument Password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda W18E 16.01.0.11 wurde eine problematische Schwachstelle entdeckt. Betroffen ist die Funktion formSetAccountList der Datei /goform/setModules. Durch Manipulieren des Arguments Password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-04T02:31:09.829Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-303157 | Tenda W18E setModules formSetAccountList stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.303157"
        },
        {
          "name": "VDB-303157 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.303157"
        },
        {
          "name": "Submit #545883 | Tenda W18E W18E V2.0-V16.01.0.11 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.545883"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/ZIKH26/tmp_store_reports/blob/main/tenda-w18e.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-04-03T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-04-03T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-04-03T15:02:25.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W18E setModules formSetAccountList stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-3203",
    "datePublished": "2025-04-04T02:31:09.829Z",
    "dateReserved": "2025-04-03T12:57:22.556Z",
    "dateUpdated": "2025-04-04T15:45:15.623Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}