Refine your search

1 vulnerability found for VxWorks 7 by Wind River

CVE-2026-97686 (GCVE-0-2026-97686)
Vulnerability from cvelistv5
Published
2026-09-28 18:48
Modified
2026-09-28 21:41
CWE
  • CWE-772 - Missing release of resource after effective lifetime
Summary
Wind River VxWorks 7 prior to 26.09, specific system call arguments can result in the IPNET subsystem failing to properly release allocated kernel memory and system file descriptors before terminating the calling application. Fixed in Version 26.09.
Impacted products
Vendor Product Version
Wind River VxWorks 7 Version: VxWorks 7
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-97686",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-28T19:25:35.769605Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-28T19:25:43.054Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "RTOS"
          ],
          "product": "VxWorks 7",
          "vendor": "Wind River",
          "versions": [
            {
              "status": "affected",
              "version": "VxWorks 7"
            }
          ]
        }
      ],
      "datePublic": "2026-09-28T18:39:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Wind River VxWorks 7 prior to 26.09, specific system call arguments can result in the IPNET subsystem failing to properly release allocated kernel memory and system file descriptors before terminating the calling application. Fixed in Version 26.09.\u0026nbsp;\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\n\n\u003cdiv\u003e\n\n\n\n\u003c/div\u003e"
            }
          ],
          "value": "Wind River VxWorks 7 prior to 26.09, specific system call arguments can result in the IPNET subsystem failing to properly release allocated kernel memory and system file descriptors before terminating the calling application. Fixed in Version 26.09."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-469",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-469 HTTP DoS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-772",
              "description": "CWE-772 Missing release of resource after effective lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-28T21:41:50.103Z",
        "orgId": "0bf9931a-6ebf-4f48-bd14-39ee5e1d61f8",
        "shortName": "WindRiver"
      },
      "references": [
        {
          "url": "https://support2.windriver.com/index.php?page=cve\u0026order_by=cve_modified_date\u0026order_way=asc#list"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "VxWorks 7 Memory Resource leak",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0bf9931a-6ebf-4f48-bd14-39ee5e1d61f8",
    "assignerShortName": "WindRiver",
    "cveId": "CVE-2026-97686",
    "datePublished": "2026-09-28T18:48:23.773Z",
    "dateReserved": "2026-09-24T21:12:17.354Z",
    "dateUpdated": "2026-09-28T21:41:50.103Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}