Refine your search

4 vulnerabilities found for Unitronics UniStream Pro/UniLogic by Unitronics

CVE-2026-45452 (GCVE-0-2026-45452)
Vulnerability from cvelistv5
Published
2026-10-15 15:25
Modified
2026-10-15 17:59
CWE
  • CWE-134 - Use of Externally-Controlled format string
Summary
Use of Externally-Controlled format string vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
Impacted products
Vendor Product Version
Unitronics Unitronics UniStream Pro/UniLogic Version: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-45452",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-15T17:58:47.636535Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-15T17:59:46.210Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unitronics UniStream Pro/UniLogic",
          "vendor": "Unitronics",
          "versions": [
            {
              "status": "affected",
              "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "SemanticGuard"
        }
      ],
      "datePublic": "2026-10-15T15:13:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of Externally-Controlled format string vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
            }
          ],
          "value": "Use of Externally-Controlled format string vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-134",
              "description": "CWE-134 Use of Externally-Controlled format string",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-15T15:25:54.445Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003e\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.42.220 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e"
            }
          ],
          "value": "Upgrade UniLogic and UniStream to version 1.42.220 or above"
        }
      ],
      "source": {
        "advisory": "ILVN-2025-0264",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics - CWE-134 Use of Externally-Controlled format string",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2026-45452",
    "datePublished": "2026-10-15T15:25:54.445Z",
    "dateReserved": "2026-05-12T15:11:23.921Z",
    "dateUpdated": "2026-10-15T17:59:46.210Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-45451 (GCVE-0-2026-45451)
Vulnerability from cvelistv5
Published
2026-10-15 15:23
Modified
2026-10-15 18:00
CWE
  • CWE-287 - Improper Authentication
Summary
: Improper Authentication vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
Impacted products
Vendor Product Version
Unitronics Unitronics UniStream Pro/UniLogic Version: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-45451",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-15T18:00:17.370132Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-15T18:00:27.448Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unitronics UniStream Pro/UniLogic",
          "vendor": "Unitronics",
          "versions": [
            {
              "status": "affected",
              "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "SemanticGuard"
        }
      ],
      "datePublic": "2026-10-15T15:13:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": ": Improper Authentication vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
            }
          ],
          "value": ": Improper Authentication vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-15T15:23:55.464Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003e\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.42.220 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e"
            }
          ],
          "value": "Upgrade UniLogic and UniStream to version 1.42.220 or above"
        }
      ],
      "source": {
        "advisory": "ILVN-2025-0263",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics - CWE-287: Improper Authentication",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2026-45451",
    "datePublished": "2026-10-15T15:23:55.464Z",
    "dateReserved": "2026-05-12T15:11:23.921Z",
    "dateUpdated": "2026-10-15T18:00:27.448Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-45450 (GCVE-0-2026-45450)
Vulnerability from cvelistv5
Published
2026-10-15 15:21
Modified
2026-10-15 18:01
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
Impacted products
Vendor Product Version
Unitronics Unitronics UniStream Pro/UniLogic Version: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-45450",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-15T18:00:51.546802Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-15T18:01:17.303Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unitronics UniStream Pro/UniLogic",
          "vendor": "Unitronics",
          "versions": [
            {
              "status": "affected",
              "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "SemanticGuard"
        }
      ],
      "datePublic": "2026-10-15T15:13:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": ": Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
            }
          ],
          "value": ": Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-15T15:21:41.203Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003e\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.42.220 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e"
            }
          ],
          "value": "Upgrade UniLogic and UniStream to version 1.42.220 or above"
        }
      ],
      "source": {
        "advisory": "ILVN-2025-0262",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics - CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2026-45450",
    "datePublished": "2026-10-15T15:21:41.203Z",
    "dateReserved": "2026-05-12T15:11:23.921Z",
    "dateUpdated": "2026-10-15T18:01:17.303Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-45449 (GCVE-0-2026-45449)
Vulnerability from cvelistv5
Published
2026-10-15 15:18
Modified
2026-10-15 18:06
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
Impacted products
Vendor Product Version
Unitronics Unitronics UniStream Pro/UniLogic Version: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-45449",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-15T18:05:49.669716Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-15T18:06:03.223Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unitronics UniStream Pro/UniLogic",
          "vendor": "Unitronics",
          "versions": [
            {
              "status": "affected",
              "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "SemanticGuard"
        }
      ],
      "datePublic": "2026-10-15T15:13:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": ": Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
            }
          ],
          "value": ": Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-15T15:18:59.438Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.41.329 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e"
            }
          ],
          "value": "Upgrade UniLogic and UniStream to version 1.41.329 or above"
        }
      ],
      "source": {
        "advisory": "ILVN-2025-0261",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics - CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2026-45449",
    "datePublished": "2026-10-15T15:18:59.438Z",
    "dateReserved": "2026-05-12T15:11:23.921Z",
    "dateUpdated": "2026-10-15T18:06:03.223Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}