Vulnerabilites related to Grandstream - UCM Series
CVE-2024-0840 (GCVE-0-2024-0840)
Vulnerability from cvelistv5
Published
2024-04-29 18:42
Modified
2024-08-01 18:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-141 - Improper Neutralization of Parameter/Argument Delimiters
Summary
The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Grandstream | UCM Series |
Version: 0 < <1.0.20.52 |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ucm6202_firmware",
"vendor": "grandstream",
"versions": [
{
"lessThan": "1.0.20.52",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ucm6204_firmware",
"vendor": "grandstream",
"versions": [
{
"lessThan": "1.0.20.52",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ucm6208_firmware",
"vendor": "grandstream",
"versions": [
{
"lessThan": "1.0.20.52",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:grandstream:ucm6510_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ucm6510_firmware",
"vendor": "grandstream",
"versions": [
{
"lessThan": "1.0.20.52",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0840",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-01T19:17:53.854809Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T13:09:24.386Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:18:18.719Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://vulncheck.com/advisories/grand-stream-param-injection"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UCM Series",
"vendor": "Grandstream",
"versions": [
{
"lessThan": "\u003c1.0.20.52",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Jacob Baines (VulnCheck)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\u003cbr\u003e"
}
],
"value": "The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\n"
}
],
"impacts": [
{
"capecId": "CAPEC-137",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-137 Parameter Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-141",
"description": "CWE-141 Improper Neutralization of Parameter/Argument Delimiters",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-29T18:42:57.112Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"url": "https://vulncheck.com/advisories/grand-stream-param-injection"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to firmware version 1.0.20.52 or later. Ensure the web interface is not exposed to the internet.\u003cbr\u003e"
}
],
"value": "Upgrade to firmware version 1.0.20.52 or later. Ensure the web interface is not exposed to the internet.\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"timeline": [
{
"lang": "en",
"time": "2024-01-25T17:00:00.000Z",
"value": "VulnCheck reports the vulnerability to Grandstream"
},
{
"lang": "en",
"time": "2024-01-26T02:00:00.000Z",
"value": "Grandstream acknowledges receipt"
},
{
"lang": "en",
"time": "2024-02-08T04:42:00.000Z",
"value": "Grandstream shares a patch build"
},
{
"lang": "en",
"time": "2024-04-26T04:11:00.000Z",
"value": "Grandstream releases 1.0.20.52"
}
],
"title": "Grandstream UCM Series IP PBX HTTP Parameter Injection",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-0840",
"datePublished": "2024-04-29T18:42:57.112Z",
"dateReserved": "2024-01-23T21:10:19.364Z",
"dateUpdated": "2024-08-01T18:18:18.719Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}