Refine your search

1 vulnerability found for Temperature Monitor Utility by BioStar

CVE-2026-94142 (GCVE-0-2026-94142)
Vulnerability from cvelistv5
Published
2026-09-21 04:45
Modified
2026-09-21 19:37
CWE
Summary
A security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200. Affected by this vulnerability is the function sub_1105C of the file BS_HWMIO64_W10.sys of the component IOCTL Handler. Such manipulation of the argument PhysicalAddress leads to write-what-where condition. The attack needs to be performed locally. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
References
https://vuldb.com/vuln/408057 vdb-entry, technical-description
https://vuldb.com/vuln/408057/cti signature, permissions-required
https://vuldb.com/cve/CVE-2026-94142 third-party-advisory
https://vuldb.com/submit/893919 third-party-advisory
Impacted products
Vendor Product Version
BioStar Temperature Monitor Utility Version: 1.2.1806.2200
    cpe:2.3:a:biostar:temperature_monitor_utility:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-94142",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-21T19:37:26.086862Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-21T19:37:32.406Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://vuldb.com/submit/893919"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:biostar:temperature_monitor_utility:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "IOCTL Handler"
          ],
          "product": "Temperature Monitor Utility",
          "vendor": "BioStar",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.1806.2200"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Bigcat (VulDB User)"
        },
        {
          "lang": "en",
          "type": "coordinator",
          "value": "VulDB CNA Team"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200. Affected by this vulnerability is the function sub_1105C of the file BS_HWMIO64_W10.sys of the component IOCTL Handler. Such manipulation of the argument PhysicalAddress leads to write-what-where condition. The attack needs to be performed locally. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:L/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-123",
              "description": "Write-what-where Condition",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-21T04:45:07.782Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-408057 | BioStar Temperature Monitor Utility IOCTL BS_HWMIO64_W10.sys sub_1105C write-what-where",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/408057"
        },
        {
          "name": "VDB-408057 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/408057/cti"
        },
        {
          "name": "CVE-2026-94142 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-94142"
        },
        {
          "name": "Submit #893919 | BioStar Temperature Monitor Utility 1.2.1806.2200 Arbitrary Kernel Memory Read/Write",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/893919"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-09-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-09-20T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-09-20T22:07:53.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "BioStar Temperature Monitor Utility IOCTL BS_HWMIO64_W10.sys sub_1105C write-what-where",
      "x_generator": [
        "VulDB PVTS v202609"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-94142",
    "datePublished": "2026-09-21T04:45:07.782Z",
    "dateReserved": "2026-09-20T20:02:48.391Z",
    "dateUpdated": "2026-09-21T19:37:32.406Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}