Vulnerabilites related to B&R Industrial Automation - Technology Guarding
CVE-2024-0220 (GCVE-0-2024-0220)
Vulnerability from cvelistv5
Published
2024-02-22 10:15
Modified
2024-09-19 17:24
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| ► | B&R Industrial Automation | Automation Studio |
Version: 4.0 |
||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:15.976Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "automation_studio",
"vendor": "br-automation",
"versions": [
{
"lessThan": "4.6",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0220",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-22T16:23:26.378691Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T16:52:09.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Upgrade Service"
],
"product": "Automation Studio",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThan": "4.6",
"status": "affected",
"version": "4.0",
"versionType": "patch"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Technology Guarding",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThan": "1.4.0",
"status": "affected",
"version": "1.0.0",
"versionType": "patch"
}
]
}
],
"datePublic": "2024-02-22T10:10:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "B\u0026amp;R Automation Studio Upgrade Service and B\u0026amp;R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.\n\n\u003cbr\u003e"
}
],
"value": "B\u0026R Automation Studio Upgrade Service and B\u0026R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1240",
"description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T17:24:51.723Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf"
}
],
"source": {
"advisory": "2023-P019",
"discovery": "INTERNAL"
},
"title": "B\u0026R products use insufficient communication encryption",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2024-0220",
"datePublished": "2024-02-22T10:15:44.750Z",
"dateReserved": "2024-01-03T15:46:41.224Z",
"dateUpdated": "2024-09-19T17:24:51.723Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}