Refine your search
2 vulnerabilities found for System Management Unit (SMU) by Hitachi Vantara
CVE-2023-6538 (GCVE-0-2023-6538)
Vulnerability from cvelistv5
Published
2023-12-11 17:54
Modified
2024-08-02 08:35
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-285 - Improper Authorization
Summary
SMU versions prior to 14.8.7825.01 are susceptible to unintended information disclosure, through URL manipulation. Authenticated users in Storage, Server or combined Server+Storage administrative roles are able to access SMU configuration backup, that would normally be barred to those specific administrative roles.
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hitachi Vantara | System Management Unit (SMU) |
Version: 6.0 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:35:13.612Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://knowledge.hitachivantara.com/Security/System_Management_Unit_(SMU)_versions_prior_to_14.8.7825.01%2C_used_to_manage_Hitachi_Vantara_NAS_products_is_susceptible_to_unintended_information_disclosure_via_unprivileged_access_to_SMU_configuration_backup_data."
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"System Management Unit (SMU)"
],
"product": "System Management Unit (SMU)",
"vendor": "Hitachi Vantara",
"versions": [
{
"lessThan": "14.8.7825.01",
"status": "affected",
"version": "6.0",
"versionType": "Full release"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Arslan Masood"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SMU versions prior to 14.8.7825.01 are susceptible to unintended information disclosure, through URL manipulation. Authenticated users in Storage, Server or combined Server+Storage administrative roles are able to access SMU configuration backup, that would normally be barred to those specific administrative roles. "
}
],
"value": "SMU versions prior to 14.8.7825.01 are susceptible to unintended information disclosure, through URL manipulation. Authenticated users in Storage, Server or combined Server+Storage administrative roles are able to access SMU configuration backup, that would normally be barred to those specific administrative roles. "
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37 Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-285",
"description": "CWE-285: Improper Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-12T16:37:19.900Z",
"orgId": "dce6e192-ff49-4263-9134-f0beccb9bc13",
"shortName": "HITVAN"
},
"references": [
{
"url": "https://knowledge.hitachivantara.com/Security/System_Management_Unit_(SMU)_versions_prior_to_14.8.7825.01%2C_used_to_manage_Hitachi_Vantara_NAS_products_is_susceptible_to_unintended_information_disclosure_via_unprivileged_access_to_SMU_configuration_backup_data."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "System Management Unit (SMU) versions prior to 14.8.7825.01, used to manage Hitachi Vantara NAS products is susceptible to unintended information disclosure via unprivileged access to SMU configuration backup data.",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "dce6e192-ff49-4263-9134-f0beccb9bc13",
"assignerShortName": "HITVAN",
"cveId": "CVE-2023-6538",
"datePublished": "2023-12-11T17:54:11.961Z",
"dateReserved": "2023-12-05T22:12:50.307Z",
"dateUpdated": "2024-08-02T08:35:13.612Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5808 (GCVE-0-2023-5808)
Vulnerability from cvelistv5
Published
2023-12-04 23:53
Modified
2024-08-28 17:34
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-285 - Improper Authorization
Summary
SMU versions prior to 14.8.7825.01 are susceptible to unintended information disclosure, through URL manipulation. Authenticated users in a Storage administrative role are able to access HNAS configuration backup and diagnostic data, that would normally be barred to that specific administrative role.
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hitachi Vantara | System Management Unit (SMU) |
Version: 6.0 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:14:23.995Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://knowledge.hitachivantara.com/Security/System_Management_Unit_(SMU)_versions_prior_to_14.8.7825.01%2C_used_to_manage_Hitachi_Vantara_NAS_products_are_susceptible_to_unintended_information_disclosure_via_unprivileged_access_to_HNAS_configuration_backup_and_diagnostic_data."
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_vantara:system_management_unit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "system_management_unit",
"vendor": "hitachi_vantara",
"versions": [
{
"lessThan": "14.8.7825.01",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5808",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-28T17:31:42.727840Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T17:34:56.347Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"System Management Unit (SMU)"
],
"product": "System Management Unit (SMU)",
"vendor": "Hitachi Vantara",
"versions": [
{
"lessThan": "14.8.7825.01",
"status": "affected",
"version": "6.0",
"versionType": "Full release"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Arslan Masood"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SMU versions prior to 14.8.7825.01 are susceptible to unintended information disclosure, through URL manipulation. Authenticated users in a Storage administrative role are able to access HNAS configuration backup and diagnostic data, that would normally be barred to that specific administrative role."
}
],
"value": "SMU versions prior to 14.8.7825.01 are susceptible to unintended information disclosure, through URL manipulation. Authenticated users in a Storage administrative role are able to access HNAS configuration backup and diagnostic data, that would normally be barred to that specific administrative role."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37: Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-285",
"description": "CWE-285: Improper Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-12T16:36:56.916Z",
"orgId": "dce6e192-ff49-4263-9134-f0beccb9bc13",
"shortName": "HITVAN"
},
"references": [
{
"url": "https://knowledge.hitachivantara.com/Security/System_Management_Unit_(SMU)_versions_prior_to_14.8.7825.01%2C_used_to_manage_Hitachi_Vantara_NAS_products_are_susceptible_to_unintended_information_disclosure_via_unprivileged_access_to_HNAS_configuration_backup_and_diagnostic_data."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "System Management Unit (SMU) versions prior to 14.8.7825.01, used to manage Hitachi Vantara NAS products are susceptible to unintended information disclosure via unprivileged access to HNAS configuration backup and diagnostic data.",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "dce6e192-ff49-4263-9134-f0beccb9bc13",
"assignerShortName": "HITVAN",
"cveId": "CVE-2023-5808",
"datePublished": "2023-12-04T23:53:33.743Z",
"dateReserved": "2023-10-26T17:39:05.623Z",
"dateUpdated": "2024-08-28T17:34:56.347Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}