Refine your search

4 vulnerabilities found for Siemens License Server (SLS) by Siemens

CVE-2026-69109 (GCVE-0-2026-69109)
Vulnerability from cvelistv5
Published
2026-08-11 12:20
Modified
2026-08-11 18:09
CWE
  • CWE-35 - Path Traversal: '.../...//'
Summary
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.3). The affected application is vulnerable to a path traversal vulnerability due to lack of sanitization of user input. This could allow a remote attacker to access arbitrary files on the application.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-69109",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-11T18:09:26.390232Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-11T18:09:36.165Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Siemens License Server (SLS)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Siemens License Server (SLS) (All versions \u003c V5.3). The affected application is vulnerable to a path traversal vulnerability due to lack of sanitization of user input. This could allow a remote attacker to access arbitrary files on the application."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-35",
              "description": "CWE-35: Path Traversal: \u0027.../...//\u0027",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-11T12:20:31.599Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-077553.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-69109",
    "datePublished": "2026-08-11T12:20:31.599Z",
    "dateReserved": "2026-08-03T13:13:45.768Z",
    "dateUpdated": "2026-08-11T18:09:36.165Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-69108 (GCVE-0-2026-69108)
Vulnerability from cvelistv5
Published
2026-08-11 12:20
Modified
2026-08-11 14:47
CWE
  • CWE-732 - Incorrect Permission Assignment for Critical Resource
Summary
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.1). The affected application is vulnerable to a local privilege escalation due to an insecure sudoers policy. This could allow an attacker to execute arbitrary commands and plant malicious files as root, leading to full system compromise.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-69108",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-11T14:47:11.495449Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-11T14:47:32.332Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Siemens License Server (SLS)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Siemens License Server (SLS) (All versions \u003c V5.1). The affected application is vulnerable to a local privilege escalation due to an insecure sudoers policy. This could allow an attacker to execute arbitrary commands and plant malicious files as root, leading to full system compromise."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-11T12:20:30.526Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-077553.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-69108",
    "datePublished": "2026-08-11T12:20:30.526Z",
    "dateReserved": "2026-08-03T13:10:24.060Z",
    "dateUpdated": "2026-08-11T14:47:32.332Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-30000 (GCVE-0-2025-30000)
Vulnerability from cvelistv5
Published
2025-04-08 08:22
Modified
2025-04-08 13:25
CWE
  • CWE-295 - Improper Certificate Validation
Summary
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application does not properly restrict permissions of the users. This could allow a lowly-privileged attacker to escalate their privileges.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30000",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T13:25:03.184802Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T13:25:21.043Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Siemens License Server (SLS)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Siemens License Server (SLS) (All versions \u003c V4.3). The affected application does not properly restrict permissions of the users. This could allow a lowly-privileged attacker to escalate their privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-295",
              "description": "CWE-295: Improper Certificate Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T08:22:29.519Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-525431.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-30000",
    "datePublished": "2025-04-08T08:22:29.519Z",
    "dateReserved": "2025-03-13T14:30:18.938Z",
    "dateUpdated": "2025-04-08T13:25:21.043Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-29999 (GCVE-0-2025-29999)
Vulnerability from cvelistv5
Published
2025-04-08 08:22
Modified
2025-04-08 13:26
CWE
  • CWE-269 - Improper Privilege Management
Summary
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application searches for executable files in the application folder without proper validation. This could allow an attacker to execute arbitrary code with administrative privileges by placing a malicious executable in the same directory.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-29999",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T13:25:44.643425Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T13:26:14.840Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Siemens License Server (SLS)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Siemens License Server (SLS) (All versions \u003c V4.3). The affected application searches for executable files in the application folder without proper validation.\r\nThis could allow an attacker to execute arbitrary code with administrative privileges by placing a malicious executable in the same directory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269: Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T08:22:28.099Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-525431.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-29999",
    "datePublished": "2025-04-08T08:22:28.099Z",
    "dateReserved": "2025-03-13T14:30:18.938Z",
    "dateUpdated": "2025-04-08T13:26:14.840Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}