Vulnerabilites related to Siemens - SCALANCE M-800
CVE-2021-25676 (GCVE-0-2021-25676)
Vulnerability from cvelistv5
Published
2021-03-15 17:03
Modified
2024-08-03 20:11
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Summary
A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically.
References
| ► | URL | Tags | ||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ► | Siemens | RUGGEDCOM RM1224 |
Version: V6.3 |
||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:11:27.563Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-296266.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "RUGGEDCOM RM1224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V6.3"
}
]
},
{
"product": "SCALANCE M-800",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V6.3"
}
]
},
{
"product": "SCALANCE S615",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V6.3"
}
]
},
{
"product": "SCALANCE SC-600",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003e= V2.1 and \u003c V2.1.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions \u003e= V2.1 and \u003c V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307: Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:21",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-296266.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-25676",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "RUGGEDCOM RM1224",
"version": {
"version_data": [
{
"version_value": "V6.3"
}
]
}
},
{
"product_name": "SCALANCE M-800",
"version": {
"version_data": [
{
"version_value": "V6.3"
}
]
}
},
{
"product_name": "SCALANCE S615",
"version": {
"version_data": [
{
"version_value": "V6.3"
}
]
}
},
{
"product_name": "SCALANCE SC-600",
"version": {
"version_data": [
{
"version_value": "All Versions \u003e= V2.1 and \u003c V2.1.3"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions \u003e= V2.1 and \u003c V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-307: Improper Restriction of Excessive Authentication Attempts"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-296266.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-296266.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-02",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-25676",
"datePublished": "2021-03-15T17:03:31",
"dateReserved": "2021-01-21T00:00:00",
"dateUpdated": "2024-08-03T20:11:27.563Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-25667 (GCVE-0-2021-25667)
Vulnerability from cvelistv5
Published
2021-03-15 17:03
Modified
2024-08-03 20:11
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
References
| ► | URL | Tags | ||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ► | Siemens | RUGGEDCOM RM1224 |
Version: All versions >= V4.3 and < V6.4 |
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:11:27.468Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "RUGGEDCOM RM1224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.3 and \u003c V6.4"
}
]
},
{
"product": "SCALANCE M-800",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.3 and \u003c V6.4"
}
]
},
{
"product": "SCALANCE S615",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V4.3 and \u003c V6.4"
}
]
},
{
"product": "SCALANCE SC-600 Family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.0 and \u003c V2.1.3"
}
]
},
{
"product": "SCALANCE XB-200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1"
}
]
},
{
"product": "SCALANCE XC-200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1"
}
]
},
{
"product": "SCALANCE XF-200BA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1"
}
]
},
{
"product": "SCALANCE XM400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.2"
}
]
},
{
"product": "SCALANCE XP-200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1"
}
]
},
{
"product": "SCALANCE XR-300WG",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1"
}
]
},
{
"product": "SCALANCE XR500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:20",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-25667",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "RUGGEDCOM RM1224",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V4.3 and \u003c V6.4"
}
]
}
},
{
"product_name": "SCALANCE M-800",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V4.3 and \u003c V6.4"
}
]
}
},
{
"product_name": "SCALANCE S615",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V4.3 and \u003c V6.4"
}
]
}
},
{
"product_name": "SCALANCE SC-600 Family",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.0 and \u003c V2.1.3"
}
]
}
},
{
"product_name": "SCALANCE XB-200",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE XC-200",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE XF-200BA",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE XM400",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V6.2"
}
]
}
},
{
"product_name": "SCALANCE XP-200",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE XR-300WG",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE XR500",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V6.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-25667",
"datePublished": "2021-03-15T17:03:31",
"dateReserved": "2021-01-21T00:00:00",
"dateUpdated": "2024-08-03T20:11:27.468Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}