Refine your search

27 vulnerabilities found for RUGGEDCOM CROSSBOW by Siemens

CVE-2026-89206 (GCVE-0-2026-89206)
Vulnerability from cvelistv5
Published
2026-10-13 09:19
Modified
2026-10-13 16:20
CWE
  • CWE-602 - Client-Side Enforcement of Server-Side Security
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform server-side authorization checks for requests to modify the state of scheduled actions. This could allow an authenticated attacker with minimal privileges to retry, stop, or delete scheduled tasks without proper authorization.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-89206",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-13T15:49:00.234601Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-13T16:20:07.016Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly perform server-side authorization checks for requests to modify the state of scheduled actions. This could allow an authenticated attacker with minimal privileges to retry, stop, or delete scheduled tasks without proper authorization."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-602",
              "description": "CWE-602: Client-Side Enforcement of Server-Side Security",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:19:10.792Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-89206",
    "datePublished": "2026-10-13T09:19:10.792Z",
    "dateReserved": "2026-09-11T07:45:20.919Z",
    "dateUpdated": "2026-10-13T16:20:07.016Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-89205 (GCVE-0-2026-89205)
Vulnerability from cvelistv5
Published
2026-10-13 09:19
Modified
2026-10-13 10:55
CWE
  • CWE-602 - Client-Side Enforcement of Server-Side Security
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform server-side authorization checks for requests to schedule special operations. This could allow an authenticated attacker with minimal privileges to schedule unauthorized operations on devices.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-89205",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-13T10:51:23.960181Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-13T10:55:08.403Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly perform server-side authorization checks for requests to schedule special operations. This could allow an authenticated attacker with minimal privileges to schedule unauthorized operations on devices."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-602",
              "description": "CWE-602: Client-Side Enforcement of Server-Side Security",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:19:09.692Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-89205",
    "datePublished": "2026-10-13T09:19:09.692Z",
    "dateReserved": "2026-09-11T07:45:20.919Z",
    "dateUpdated": "2026-10-13T10:55:08.403Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-89204 (GCVE-0-2026-89204)
Vulnerability from cvelistv5
Published
2026-10-13 09:19
Modified
2026-10-13 16:20
CWE
  • CWE-639 - Authorization Bypass Through User-Controlled Key
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to database queries used for subnet management. This could allow an authenticated attacker to read, modify, or delete subnet configurations, leading to unauthorized information disclosure and data manipulation.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-89204",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-13T15:49:09.830394Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-13T16:20:07.151Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly restrict access to database queries used for subnet management. This could allow an authenticated attacker to read, modify, or delete subnet configurations, leading to unauthorized information disclosure and data manipulation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-639",
              "description": "CWE-639: Authorization Bypass Through User-Controlled Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:19:08.604Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-89204",
    "datePublished": "2026-10-13T09:19:08.604Z",
    "dateReserved": "2026-09-11T07:45:20.919Z",
    "dateUpdated": "2026-10-13T16:20:07.151Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-89203 (GCVE-0-2026-89203)
Vulnerability from cvelistv5
Published
2026-10-13 09:19
Modified
2026-10-13 12:59
CWE
  • CWE-201 - Insertion of Sensitive Information Into Sent Data
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to various database queries, allowing users to retrieve system-wide information that is not intended for their privilege level. This could allow an authenticated attacker to gather sensitive information about the system's infrastructure, including details on all devices, substations, users, and scheduled activities.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-89203",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-13T12:59:31.162993Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-13T12:59:52.711Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly restrict access to various database queries, allowing users to retrieve system-wide information that is not intended for their privilege level. This could allow an authenticated attacker to gather sensitive information about the system\u0027s infrastructure, including details on all devices, substations, users, and scheduled activities."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-201",
              "description": "CWE-201: Insertion of Sensitive Information Into Sent Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:19:07.497Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-89203",
    "datePublished": "2026-10-13T09:19:07.497Z",
    "dateReserved": "2026-09-11T07:45:20.919Z",
    "dateUpdated": "2026-10-13T12:59:52.711Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-89202 (GCVE-0-2026-89202)
Vulnerability from cvelistv5
Published
2026-10-13 09:19
Modified
2026-10-16 17:17
CWE
  • CWE-639 - Authorization Bypass Through User-Controlled Key
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform authorization checks for device disconnection requests. This could allow an authenticated attacker with minimal privileges to disconnect active sessions of other users, including administrators, leading to a denial of service.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-89202",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-16T17:01:46.556256Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-16T17:17:49.500Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly perform authorization checks for device disconnection requests. This could allow an authenticated attacker with minimal privileges to disconnect active sessions of other users, including administrators, leading to a denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-639",
              "description": "CWE-639: Authorization Bypass Through User-Controlled Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:19:06.397Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-89202",
    "datePublished": "2026-10-13T09:19:06.397Z",
    "dateReserved": "2026-09-11T07:45:20.919Z",
    "dateUpdated": "2026-10-16T17:17:49.500Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-89201 (GCVE-0-2026-89201)
Vulnerability from cvelistv5
Published
2026-10-13 09:19
Modified
2026-10-14 19:28
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in device group or facility names processed during the Bulk Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-89201",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-14T19:27:53.203857Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-14T19:28:00.768Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly validate or sanitize input in device group or facility names processed during the Bulk Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:19:05.287Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-89201",
    "datePublished": "2026-10-13T09:19:05.287Z",
    "dateReserved": "2026-09-11T07:45:20.919Z",
    "dateUpdated": "2026-10-14T19:28:00.768Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-89200 (GCVE-0-2026-89200)
Vulnerability from cvelistv5
Published
2026-10-13 09:19
Modified
2026-10-13 10:56
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in the Name and Value fields for custom file labels. This could allow an authenticated attacker with administrative privileges to execute arbitrary SQL commands on the underlying database.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-89200",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-13T10:56:38.316796Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-13T10:56:50.972Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly validate or sanitize input in the Name and Value fields for custom file labels. This could allow an authenticated attacker with administrative privileges to execute arbitrary SQL commands on the underlying database."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:19:04.165Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-89200",
    "datePublished": "2026-10-13T09:19:04.165Z",
    "dateReserved": "2026-09-11T07:45:20.919Z",
    "dateUpdated": "2026-10-13T10:56:50.972Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-89199 (GCVE-0-2026-89199)
Vulnerability from cvelistv5
Published
2026-10-13 09:19
Modified
2026-10-13 16:20
CWE
  • CWE-639 - Authorization Bypass Through User-Controlled Key
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to sensitive configuration items via specific database queries. This could allow an authenticated attacker to retrieve administrative credentials for various internal systems, leading to unauthorized information disclosure and privilege escalation.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-89199",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-13T15:49:43.544073Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-13T16:20:07.271Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly restrict access to sensitive configuration items via specific database queries. This could allow an authenticated attacker to retrieve administrative credentials for various internal systems, leading to unauthorized information disclosure and privilege escalation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-639",
              "description": "CWE-639: Authorization Bypass Through User-Controlled Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:19:03.033Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-89199",
    "datePublished": "2026-10-13T09:19:03.033Z",
    "dateReserved": "2026-09-11T07:45:20.919Z",
    "dateUpdated": "2026-10-13T16:20:07.271Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-89198 (GCVE-0-2026-89198)
Vulnerability from cvelistv5
Published
2026-10-13 09:19
Modified
2026-10-13 12:59
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize the filename of firmware files uploaded to the system. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-89198",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-13T12:58:41.126504Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-13T12:59:04.508Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly validate or sanitize the filename of firmware files uploaded to the system. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:19:01.894Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-89198",
    "datePublished": "2026-10-13T09:19:01.894Z",
    "dateReserved": "2026-09-11T07:45:20.918Z",
    "dateUpdated": "2026-10-13T12:59:04.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-89197 (GCVE-0-2026-89197)
Vulnerability from cvelistv5
Published
2026-10-13 09:19
Modified
2026-10-16 17:17
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in the Value field of notification conditions processed during the Notification Profile configuration. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-89197",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-16T17:00:06.629650Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-16T17:17:58.161Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly validate or sanitize input in the Value field of notification conditions processed during the Notification Profile configuration. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:19:00.790Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-89197",
    "datePublished": "2026-10-13T09:19:00.790Z",
    "dateReserved": "2026-09-11T07:45:20.918Z",
    "dateUpdated": "2026-10-16T17:17:58.161Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-89196 (GCVE-0-2026-89196)
Vulnerability from cvelistv5
Published
2026-10-13 09:18
Modified
2026-10-14 19:26
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in facility names processed during the Bulk Import/Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V6.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-89196",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-14T19:26:33.554482Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-14T19:26:44.566Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V6.0). Affected devices do not properly validate or sanitize input in facility names processed during the Bulk Import/Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:18:59.688Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-508506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-89196",
    "datePublished": "2026-10-13T09:18:59.688Z",
    "dateReserved": "2026-09-11T07:45:20.918Z",
    "dateUpdated": "2026-10-14T19:26:44.566Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-27947 (GCVE-0-2024-27947)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 00:41
CWE
  • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems could allow log messages to be forwarded to a specific client under certain circumstances. An attacker could leverage this vulnerability to forward log messages to a specific compromised client.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V5.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_crossbow:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_crossbow",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "5.5",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27947",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:11:20.368566Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:46:57.751Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:55.819Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.5). The affected systems could allow log messages to be forwarded to a specific client under certain circumstances. An attacker could leverage this vulnerability to forward log messages to a specific compromised client."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:24:06.218Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-27947",
    "datePublished": "2024-05-14T10:02:16.725Z",
    "dateReserved": "2024-02-28T16:38:00.193Z",
    "dateUpdated": "2024-08-02T00:41:55.819Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27946 (GCVE-0-2024-27946)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 00:41
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Downloading files overwrites files with the same name in the installation directory of the affected systems. The filename for the target file can be specified, thus arbitrary files can be overwritten by an attacker with the required privileges.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V5.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_crossbow:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_crossbow",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "5.5",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27946",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:10:45.471706Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:46:45.178Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:55.909Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.5). Downloading files overwrites files with the same name in the \r\ninstallation directory of the affected systems. The filename for \r\nthe target file can be specified, thus arbitrary files can be \r\noverwritten by an attacker with the required privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:24:04.948Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-27946",
    "datePublished": "2024-05-14T10:02:15.551Z",
    "dateReserved": "2024-02-28T16:38:00.193Z",
    "dateUpdated": "2024-08-02T00:41:55.909Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27945 (GCVE-0-2024-27945)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 00:41
CWE
  • CWE-73 - External Control of File Name or Path
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The bulk import feature of the affected systems allow a privileged user to upload files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V5.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_crossbow:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_crossbow",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "5.5",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27945",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:05:16.300573Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:47:11.549Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:55.904Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.5). The bulk import feature of the affected systems allow a privileged user to upload files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-73",
              "description": "CWE-73: External Control of File Name or Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:24:03.800Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-27945",
    "datePublished": "2024-05-14T10:02:14.365Z",
    "dateReserved": "2024-02-28T16:38:00.193Z",
    "dateUpdated": "2024-08-02T00:41:55.904Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27944 (GCVE-0-2024-27944)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 00:41
CWE
  • CWE-73 - External Control of File Name or Path
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload firmware files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V5.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_crossbow:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_crossbow",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "5.5",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27944",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:11:51.980476Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:47:03.078Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:55.820Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.5). The affected systems allow a privileged user to upload firmware files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-73",
              "description": "CWE-73: External Control of File Name or Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:24:02.656Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-27944",
    "datePublished": "2024-05-14T10:02:13.176Z",
    "dateReserved": "2024-02-28T16:38:00.193Z",
    "dateUpdated": "2024-08-02T00:41:55.820Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27943 (GCVE-0-2024-27943)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 00:41
CWE
  • CWE-73 - External Control of File Name or Path
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload generic files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V5.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_crossbow:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_crossbow",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "5.5",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27943",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:12:14.963106Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:47:29.491Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:55.786Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.5). The affected systems allow a privileged user to upload generic files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-73",
              "description": "CWE-73: External Control of File Name or Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:24:01.461Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-27943",
    "datePublished": "2024-05-14T10:02:11.931Z",
    "dateReserved": "2024-02-28T16:38:00.193Z",
    "dateUpdated": "2024-08-02T00:41:55.786Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27942 (GCVE-0-2024-27942)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 00:41
CWE
  • CWE-306 - Missing Authentication for Critical Function
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow any unauthenticated client to disconnect any active user from the server. An attacker could use this vulnerability to prevent any user to perform actions in the system, causing a denial of service situation.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V5.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_crossbow:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_crossbow",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "5.5",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27942",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:13:06.993213Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:47:24.431Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:55.821Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.5). The affected systems allow any unauthenticated client to disconnect any active user from the server. An attacker could use this vulnerability to prevent any user to perform actions in the system, causing a denial of service situation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:24:00.296Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-27942",
    "datePublished": "2024-05-14T10:02:10.764Z",
    "dateReserved": "2024-02-28T16:38:00.192Z",
    "dateUpdated": "2024-08-02T00:41:55.821Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27941 (GCVE-0-2024-27941)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 00:41
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected client systems do not properly sanitize input data before sending it to the SQL server. An attacker could use this vulnerability to compromise the whole database.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V5.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_crossbow:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_crossbow",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "5.5",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27941",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:13:26.925260Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:46:35.926Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:55.801Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.5). The affected client systems do not properly sanitize input data before sending it to the SQL server. An attacker could use this vulnerability to compromise the whole database."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:23:59.115Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-27941",
    "datePublished": "2024-05-14T10:02:09.602Z",
    "dateReserved": "2024-02-28T16:38:00.192Z",
    "dateUpdated": "2024-08-02T00:41:55.801Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27940 (GCVE-0-2024-27940)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 00:41
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow any authenticated user to send arbitrary SQL commands to the SQL server. An attacker could use this vulnerability to compromise the whole database.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V5.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_crossbow:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_crossbow",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "5.5",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27940",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:13:49.665028Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:46:23.391Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:55.962Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.5). The affected systems allow any authenticated user to send arbitrary SQL commands to the SQL server. An attacker could use this vulnerability to compromise the whole database."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:23:57.950Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-27940",
    "datePublished": "2024-05-14T10:02:08.412Z",
    "dateReserved": "2024-02-28T16:38:00.192Z",
    "dateUpdated": "2024-08-02T00:41:55.962Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27939 (GCVE-0-2024-27939)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 00:41
CWE
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow the upload of arbitrary files of any unauthenticated user. An attacker could leverage this vulnerability and achieve arbitrary code execution with system privileges.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V5.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_crossbow:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_crossbow",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "5.5",
                "status": "affected",
                "version": "-",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27939",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T13:14:26.996528Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:47:23.121Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:55.764Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.5). The affected systems allow the upload of arbitrary files of any unauthenticated user. An attacker could leverage this vulnerability and achieve arbitrary code execution with system privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "CWE-862: Missing Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:23:56.803Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-916916.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-27939",
    "datePublished": "2024-05-14T10:02:07.190Z",
    "dateReserved": "2024-02-28T16:38:00.192Z",
    "dateUpdated": "2024-08-02T00:41:55.764Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-37373 (GCVE-0-2023-37373)
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2025-02-27 21:10
CWE
  • CWE-306 - Missing Authentication for Critical Function
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications accept unauthenticated file write messages. An unauthenticated remote attacker could write arbitrary files to the affected application's file system.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: All versions < V5.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:09:34.314Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-472630.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-37373",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T21:50:59.302142Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T21:10:15.750Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.4). The affected applications accept unauthenticated file write messages. An unauthenticated remote attacker could write arbitrary files to the affected application\u0027s file system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:28.582Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-472630.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-37373",
    "datePublished": "2023-08-08T09:20:28.582Z",
    "dateReserved": "2023-07-03T09:11:22.346Z",
    "dateUpdated": "2025-02-27T21:10:15.750Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-37372 (GCVE-0-2023-37372)
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2025-02-27 21:10
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an unauthenticated remote attackers to execute arbitrary SQL queries on the server database.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: All versions < V5.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:09:34.197Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-472630.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-37372",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T21:51:11.615536Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T21:10:21.124Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.4). The affected applications is vulnerable to SQL injection. This could allow an unauthenticated remote attackers to execute arbitrary SQL queries on the server database."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:27.473Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-472630.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-37372",
    "datePublished": "2023-08-08T09:20:27.473Z",
    "dateReserved": "2023-07-03T09:11:22.346Z",
    "dateUpdated": "2025-02-27T21:10:21.124Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-27411 (GCVE-0-2023-27411)
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2025-02-27 21:10
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an authenticated remote attackers to execute arbitrary SQL queries on the server database and escalate privileges.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: All versions < V5.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:09:43.334Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-472630.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-27411",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T21:54:20.267618Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T21:10:28.041Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.4). The affected applications is vulnerable to SQL injection. This could allow an authenticated remote attackers to execute arbitrary SQL queries on the server database and escalate privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:16.661Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-472630.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-27411",
    "datePublished": "2023-08-08T09:20:16.661Z",
    "dateReserved": "2023-03-01T14:07:57.359Z",
    "dateUpdated": "2025-02-27T21:10:28.041Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-27463 (GCVE-0-2023-27463)
Vulnerability from cvelistv5
Published
2023-03-14 09:32
Modified
2025-02-27 18:59
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.3). The audit log form of affected applications is vulnerable to SQL injection. This could allow authenticated remote attackers to execute arbitrary SQL queries on the server database.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: All versions < V5.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:09:43.475Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-320629.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-27463",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-27T18:59:15.597009Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T18:59:38.671Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.3). The audit log form of affected applications is vulnerable to SQL injection. This could allow authenticated remote attackers to execute arbitrary SQL queries on the server database."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-14T09:32:09.667Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-320629.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-27463",
    "datePublished": "2023-03-14T09:32:09.667Z",
    "dateReserved": "2023-03-01T17:29:28.824Z",
    "dateUpdated": "2025-02-27T18:59:38.671Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-27462 (GCVE-0-2023-27462)
Vulnerability from cvelistv5
Published
2023-03-14 09:32
Modified
2025-02-27 15:59
CWE
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.3). The client query handler of the affected application fails to check for proper permissions for specific read queries. This could allow authenticated remote attackers to access data they are not authorized for.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: All versions < V5.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:09:43.431Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-320629.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-27462",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-27T15:59:39.445388Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T15:59:48.613Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.3). The client query handler of the affected application fails to check for proper permissions for specific read queries. This could allow authenticated remote attackers to access data they are not authorized for."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.1,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "CWE-862: Missing Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-14T09:32:08.607Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-320629.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-27462",
    "datePublished": "2023-03-14T09:32:08.607Z",
    "dateReserved": "2023-03-01T17:29:28.823Z",
    "dateUpdated": "2025-02-27T15:59:48.613Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-27310 (GCVE-0-2023-27310)
Vulnerability from cvelistv5
Published
2023-03-14 09:31
Modified
2025-02-27 19:01
CWE
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). The client query handler of the affected application fails to check for proper permissions when assigning groups to user accounts. This could allow an authenticated remote attacker to assign administrative groups to otherwise non-privileged user accounts.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: All versions < V5.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:09:42.950Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-260625.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-27310",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-27T19:00:56.736160Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T19:01:06.092Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.2). The client query handler of the affected application fails to check for proper permissions when assigning groups to user accounts. This could allow an authenticated remote attacker to assign administrative groups to otherwise non-privileged user accounts."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "CWE-862: Missing Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-14T09:31:58.178Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-260625.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-27310",
    "datePublished": "2023-03-14T09:31:58.178Z",
    "dateReserved": "2023-02-28T09:05:35.296Z",
    "dateUpdated": "2025-02-27T19:01:06.092Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-27309 (GCVE-0-2023-27309)
Vulnerability from cvelistv5
Published
2023-03-14 09:31
Modified
2025-02-27 15:00
CWE
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). The client query handler of the affected application fails to check for proper permissions for specific write queries. This could allow an authenticated remote attacker to perform unauthorized actions.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: All versions < V5.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:09:43.454Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-260625.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-27309",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-27T14:59:44.203179Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T15:00:08.924Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM CROSSBOW",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions \u003c V5.2). The client query handler of the affected application fails to check for proper permissions for specific write queries. This could allow an authenticated remote attacker to perform unauthorized actions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "CWE-862: Missing Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-14T09:31:57.134Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-260625.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-27309",
    "datePublished": "2023-03-14T09:31:57.134Z",
    "dateReserved": "2023-02-28T09:05:35.296Z",
    "dateUpdated": "2025-02-27T15:00:08.924Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}