Refine your search

1 vulnerability found for Plantronics Hub by Poly

CVE-2024-6147 (GCVE-0-2024-6147)
Vulnerability from cvelistv5
Published
2024-06-20 20:11
Modified
2024-08-01 21:33
CWE
  • CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Summary
Poly Plantronics Hub Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Poly Plantronics Hub. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the Spokes Update Service. By creating a symbolic link, an attacker can abuse the service to delete a file. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-18271.
References
Impacted products
Vendor Product Version
Poly Plantronics Hub Version: 3.24.2 Build 36336
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:plantronics:plantronics_hub:*:*:*:*:*:windows:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "plantronics_hub",
            "vendor": "plantronics",
            "versions": [
              {
                "status": "affected",
                "version": "3.24.2 Build 36336"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6147",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T19:21:00.721267Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T19:40:03.741Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:33:04.947Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "ZDI-24-802",
            "tags": [
              "x_research-advisory",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-802/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Plantronics Hub",
          "vendor": "Poly",
          "versions": [
            {
              "status": "affected",
              "version": "3.24.2 Build 36336"
            }
          ]
        }
      ],
      "dateAssigned": "2024-06-18T21:11:49.104Z",
      "datePublic": "2024-06-18T23:32:18.515Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Poly Plantronics Hub Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Poly Plantronics Hub. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the Spokes Update Service. By creating a symbolic link, an attacker can abuse the service to delete a file. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-18271."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-59",
              "description": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-20T20:11:52.626Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-802",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-802/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "Michael DePlante (@izobashi) of Trend Micro\u0027s Zero Day Initiative"
      },
      "title": "Poly Plantronics Hub Link Following Local Privilege Escalation Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-6147",
    "datePublished": "2024-06-20T20:11:52.626Z",
    "dateReserved": "2024-06-18T21:11:49.077Z",
    "dateUpdated": "2024-08-01T21:33:04.947Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}