7 vulnerabilities found for OnCell G3150A-LTE Series by Moxa
CVE-2026-111461 (GCVE-0-2026-111461)
Vulnerability from cvelistv5
Published
2026-10-27 07:17
Modified
2026-10-27 07:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
An OS command injection vulnerability exists inĀ OnCell G3150A-LTE Series. When the SMS management functionality is enabled and configured, a remote attacker with the required privileges could exploit insufficient input validation in the SMS management functionality to execute arbitrary commands on the affected device.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Moxa | OnCell G3150A-LTE Series |
Version: 1.0.0 < |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "OnCell G3150A-LTE Series",
"vendor": "Moxa",
"versions": [
{
"status": "affected",
"version": "1.0.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:moxa:oncell_g3150a-lte_series:1.0.0:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Abhinav Agarwal"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An OS command injection vulnerability exists in\u0026nbsp;OnCell G3150A-LTE Series. When the SMS management functionality is enabled and configured, a remote attacker with the required privileges could exploit insufficient input validation in the SMS management functionality to execute arbitrary commands on the affected device."
}
],
"value": "An OS command injection vulnerability exists in\u00a0OnCell G3150A-LTE Series. When the SMS management functionality is enabled and configured, a remote attacker with the required privileges could exploit insufficient input validation in the SMS management functionality to execute arbitrary commands on the affected device."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88: OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-27T07:17:01.566Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-269510-cve-2026-111459-cve-2026-111460-cve-2026-111461-vulnerabilities-in-moxa-remote-connect-suite-mrc-client"
}
],
"source": {
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "SMS upgrade argument reaches system() unescaped in OnCell G3150A-LTE Series",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePlease refer to\u0026nbsp;the following mitigation measures to reduce the risk of exploitation:\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003cspan\u003eFor \u003c/span\u003e\u003cspan\u003eCVE-2026-111461, k\u003c/span\u003e\u003cspan\u003eeep the SMS functionality disabled unless it is required for operation. This functionality is disabled by default. If it is not needed, Moxa recommends leaving it disabled to reduce the risk of exploitation.\u003c/span\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Please refer to\u00a0the following mitigation measures to reduce the risk of exploitation:\n\n * \n\nFor CVE-2026-111461, keep the SMS functionality disabled unless it is required for operation. This functionality is disabled by default. If it is not needed, Moxa recommends leaving it disabled to reduce the risk of exploitation."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2026-111461",
"datePublished": "2026-10-27T07:17:01.566Z",
"dateReserved": "2026-10-16T05:36:39.412Z",
"dateUpdated": "2026-10-27T07:17:01.566Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-111460 (GCVE-0-2026-111460)
Vulnerability from cvelistv5
Published
2026-10-27 07:13
Modified
2026-10-27 07:13
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-321 - Use of Hard-coded Cryptographic Key
Summary
A hard-coded cryptographic key vulnerability exists in the OnCell G3150A-LTE Series. Under certain conditions, an unauthenticated remote attacker could obtain shared cryptographic key material and use it to impersonate affected devicesĀ that have not regenerated their cryptographic keys, potentially compromising the confidentiality and integrity of management communications.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Moxa | OnCell G3150A-LTE Series |
Version: 1.0.0 < |
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "OnCell G3150A-LTE Series",
"vendor": "Moxa",
"versions": [
{
"status": "affected",
"version": "1.0.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:moxa:oncell_g3150a-lte_series:1.0.0:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Abhinav Agarwal"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A hard-coded cryptographic key vulnerability exists in the OnCell G3150A-LTE Series. Under certain conditions, an unauthenticated remote attacker could obtain shared cryptographic key material and use it to impersonate affected devices\u0026nbsp;that have not regenerated their cryptographic keys, potentially compromising the confidentiality and integrity of management communications."
}
],
"value": "A hard-coded cryptographic key vulnerability exists in the OnCell G3150A-LTE Series. Under certain conditions, an unauthenticated remote attacker could obtain shared cryptographic key material and use it to impersonate affected devices\u00a0that have not regenerated their cryptographic keys, potentially compromising the confidentiality and integrity of management communications."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37: Retrieves Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321: Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-27T07:13:51.550Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-269510-cve-2026-111459-cve-2026-111460-cve-2026-111461-vulnerabilities-in-moxa-remote-connect-suite-mrc-client"
}
],
"source": {
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Static HTTPS private key and CA private key in firmware in OnCell G3150A-LTE Series",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePlease refer to\u0026nbsp;the following mitigation measures to reduce the risk of exploitation:\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eFor CVE-2026-111460, reset the affected device to regenerate the device certificate and associated cryptographic key material.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Please refer to\u00a0the following mitigation measures to reduce the risk of exploitation:\n\n * \n\nFor CVE-2026-111460, reset the affected device to regenerate the device certificate and associated cryptographic key material."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2026-111460",
"datePublished": "2026-10-27T07:13:51.550Z",
"dateReserved": "2026-10-16T05:36:37.951Z",
"dateUpdated": "2026-10-27T07:13:51.550Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-4641 (GCVE-0-2024-4641)
Vulnerability from cvelistv5
Published
2024-06-25 09:23
Modified
2024-08-01 20:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-134 - Use of Externally-Controlled Format String
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Moxa | OnCell G3150A-LTE Series |
Version: 1.0 < |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "oncell_g3470a-lte-us",
"vendor": "moxa",
"versions": [
{
"lessThanOrEqual": "1.7.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4641",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-26T17:38:59.616518Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-26T17:39:20.742Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:47:41.226Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "OnCell G3150A-LTE Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "1.7.7",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Nikita Abramov from Positive Technologies"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service."
}
],
"value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service."
}
],
"impacts": [
{
"capecId": "CAPEC-135",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-135: Format String Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134: Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-25T09:23:30.502Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
}
],
"value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n\n\n\n * OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "OnCell G3470A-LTE Series: Authenticated Format String Errors",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Moxa recommends users to implement the following mitigations if necessary: \n\n * Minimize network exposure to ensure the device is not accessible from the Internet. \n * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n * The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2024-4641",
"datePublished": "2024-06-25T09:23:30.502Z",
"dateReserved": "2024-05-08T00:44:45.219Z",
"dateUpdated": "2024-08-01T20:47:41.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4640 (GCVE-0-2024-4640)
Vulnerability from cvelistv5
Published
2024-06-25 09:19
Modified
2024-08-01 20:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Moxa | OnCell G3150A-LTE Series |
Version: 1.0 < |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4640",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-25T13:15:03.203557Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-25T13:15:08.856Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:47:41.484Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "OnCell G3150A-LTE Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "1.7.7",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Nikita Abramov from Positive Technologies"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash."
}
],
"value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100: Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-25T09:19:08.712Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
}
],
"value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n\n\n\n * OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "OnCell G3470A-LTE Series: Authenticated Command Injection via sendTestEmail",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Moxa recommends users to implement the following mitigations if necessary: \n\n * Minimize network exposure to ensure the device is not accessible from the Internet. \n * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n * The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2024-4640",
"datePublished": "2024-06-25T09:19:08.712Z",
"dateReserved": "2024-05-08T00:44:43.828Z",
"dateUpdated": "2024-08-01T20:47:41.484Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4639 (GCVE-0-2024-4639)
Vulnerability from cvelistv5
Published
2024-06-25 09:15
Modified
2024-08-01 20:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Moxa | OnCell G3150A-LTE Series |
Version: 1.0 < |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4639",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-25T13:34:53.804173Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-25T13:35:01.665Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:47:41.194Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "OnCell G3150A-LTE Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "1.7.7",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Nikita Abramov from Positive Technologies"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
}
],
"value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
}
],
"impacts": [
{
"capecId": "CAPEC-248",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-248: Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-25T09:15:03.229Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003cbr\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n * OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "OnCell G3470A-LTE Series: Authenticated Command Injection via webDelIPSec",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Moxa recommends users to implement the following mitigations if necessary: \n\n * Minimize network exposure to ensure the device is not accessible from the Internet. \n * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n * The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2024-4639",
"datePublished": "2024-06-25T09:15:03.229Z",
"dateReserved": "2024-05-08T00:44:42.405Z",
"dateUpdated": "2024-08-01T20:47:41.194Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6094 (GCVE-0-2023-6094)
Vulnerability from cvelistv5
Published
2023-12-31 09:57
Modified
2024-08-26 20:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Summary
A vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Moxa | OnCell G3150A-LTE Series |
Version: 1.0 < |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:21:17.204Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-6094",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-26T20:21:02.392909Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-26T20:21:09.811Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "OnCell G3150A-LTE Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "1.3",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.\u003c/p\u003e"
}
],
"value": "A vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. The vulnerability results from lack of protection for sensitive information during transmission. An attacker eavesdropping on the traffic between the web browser and server may obtain sensitive information. This type of attack could be executed to gather sensitive information or to facilitate a subsequent attack against the target.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-117",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-117: Interception"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-04T15:08:08.275Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "OnCell G3150A-LTE Series: Web Server Transmits Cleartext Credentials",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSince Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093 and CVE-2023-6094. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \u003c/p\u003e\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eReduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003ePlace control system networks and remote devices behind firewalls, isolating them from business networks. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003eWhen remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Since Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093 and CVE-2023-6094. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \n\nMoxa recommends users to implement the following mitigations if necessary: \n\n * Reduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \n\n\n * Place control system networks and remote devices behind firewalls, isolating them from business networks. \n\n\n * When remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\n\n\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2023-6094",
"datePublished": "2023-12-31T09:57:27.448Z",
"dateReserved": "2023-11-13T02:17:37.177Z",
"dateUpdated": "2024-08-26T20:21:09.811Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6093 (GCVE-0-2023-6093)
Vulnerability from cvelistv5
Published
2023-12-31 09:53
Modified
2024-08-02 08:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-1021 - Improper Restriction of Rendered UI Layers or Frames
Summary
A clickjacking vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. This vulnerability is caused by incorrectly restricts frame objects, which can lead to user confusion about which interface the user is interacting with. This vulnerability may lead the attacker to trick the user into interacting with the application.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Moxa | OnCell G3150A-LTE Series |
Version: 1.0 < |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:21:17.143Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "OnCell G3150A-LTE Series",
"vendor": "Moxa",
"versions": [
{
"lessThanOrEqual": "1.3",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA clickjacking vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. This vulnerability is caused by incorrectly restricts frame objects, which can lead to user confusion about which interface the user is interacting with. This vulnerability may lead the attacker to trick the user into interacting with the application.\u003c/p\u003e"
}
],
"value": "A clickjacking vulnerability has been identified in OnCell G3150A-LTE Series firmware versions v1.3 and prior. This vulnerability is caused by incorrectly restricts frame objects, which can lead to user confusion about which interface the user is interacting with. This vulnerability may lead the attacker to trick the user into interacting with the application.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-103",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-103: Clickjacking"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1021",
"description": "CWE-1021: Improper Restriction of Rendered UI Layers or Frames",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-04T14:59:17.638Z",
"orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"shortName": "Moxa"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/oncell-g3150a-lte-series-multiple-web-application-vulnerabilities-and-security-enhancement"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "OnCell G3150A-LTE Series: Clickjacking Vulnerability",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003e\u003c/p\u003e\u003cp\u003eSince Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \u0026nbsp;\u003c/p\u003e\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eReduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003ePlace control system networks and remote devices behind firewalls, isolating them from business networks. \u003c/p\u003e\u003c/li\u003e\u003cli\u003e\u003cp\u003eWhen remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
}
],
"value": "\n\n\nSince Oncell G3150A-LTE has been phased out, we don\u2019t have any plans to address CVE 2023-6093. We recommend that users follow the mitigation measures below to deploy the product in an appropriate product security context. \u00a0\n\nMoxa recommends users to implement the following mitigations if necessary: \n\n * Reduce network exposure by ensuring that all control system devices and systems are not accessible from the Internet. \n\n\n * Place control system networks and remote devices behind firewalls, isolating them from business networks. \n\n\n * When remote access is necessary, employ secure methods such as Virtual Private Networks (VPNs). It is important to note that VPNs may have vulnerabilities and should be kept up to date with the latest available version. Remember that the security of a VPN depends on the security of its connected devices.\n\n\n\n\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
"assignerShortName": "Moxa",
"cveId": "CVE-2023-6093",
"datePublished": "2023-12-31T09:53:04.790Z",
"dateReserved": "2023-11-13T02:17:35.853Z",
"dateUpdated": "2024-08-02T08:21:17.143Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}