Refine your search

1 vulnerability found for Nova 430H eNodeB (model pBS3101SH) by Baicells

CVE-2026-96274 (GCVE-0-2026-96274)
Vulnerability from cvelistv5
Published
2026-09-29 19:29
Modified
2026-09-29 21:01
CWE
Summary
In Baicells Nova 430H, an unauthenticated device within radio range can send a malformed uplink message during connection setup that contains an invalid NAS payload. Because the eNodeB does not properly validate this payload, it forwards the message to the core network, which can trigger a shutdown of the signaling association for the cell. This results in a temporary service disruption until the eNodeB and core network re-establish connectivity.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-96274",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-29T20:57:13.860311Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-29T21:01:58.604Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nova 430H eNodeB  (model pBS3101SH)",
          "vendor": "Baicells",
          "versions": [
            {
              "lessThanOrEqual": "BaiBLQ_3.0.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Qiqing Huang reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In Baicells Nova 430H, an unauthenticated device within radio range can send a malformed uplink message during connection setup that contains an invalid NAS payload. Because the eNodeB does not properly validate this payload, it forwards the message to the core network, which can trigger a shutdown of the signaling association for the cell. This results in a temporary service disruption until the eNodeB and core network re-establish connectivity.\u0026nbsp;\u003cbr\u003e"
            }
          ],
          "value": "In Baicells Nova 430H, an unauthenticated device within radio range can send a malformed uplink message during connection setup that contains an invalid NAS payload. Because the eNodeB does not properly validate this payload, it forwards the message to the core network, which can trigger a shutdown of the signaling association for the cell. This results in a temporary service disruption until the eNodeB and core network re-establish connectivity."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248 Uncaught exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-29T19:29:13.172Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-272-04"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Uncaught exception in Baicells Nova 430H",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-96274",
    "datePublished": "2026-09-29T19:29:13.172Z",
    "dateReserved": "2026-09-22T20:38:24.656Z",
    "dateUpdated": "2026-09-29T21:01:58.604Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}