Refine your search

1 vulnerability found for NotionNext by notionnext-org

CVE-2026-101004 (GCVE-0-2026-101004)
Vulnerability from cvelistv5
Published
2026-09-28 05:45
Modified
2026-09-28 12:27
CWE
Summary
A security vulnerability has been detected in notionnext-org NotionNext up to 4.10.10. Affected by this issue is the function cleanCache of the file pages/api/cache.js of the component Authentication Guard. The manipulation of the argument token leads to missing authentication. The attack may be initiated remotely. Versions 4.1.0 - 4.9.5.2 allow unauthenticated exploitation due to missing method check. In versions 4.9.5.7 - 4.10.10 a guard present but only enforced when CACHE_REVALIDATION_TOKEN is set. Default deployments remain unprotected. The vendor was contacted early about this disclosure but did not respond in any way.
References
https://vuldb.com/vuln/410874 vdb-entry, technical-description
https://vuldb.com/vuln/410874/cti signature, permissions-required
https://vuldb.com/cve/CVE-2026-101004 third-party-advisory
https://vuldb.com/submit/920379 third-party-advisory
Impacted products
Vendor Product Version
notionnext-org NotionNext Version: 4.10.0
Version: 4.10.1
Version: 4.10.2
Version: 4.10.3
Version: 4.10.4
Version: 4.10.5
Version: 4.10.6
Version: 4.10.7
Version: 4.10.8
Version: 4.10.9
Version: 4.10.10
    cpe:2.3:a:notionnext-org:notionnext:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-101004",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-28T12:24:56.792981Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-28T12:27:03.397Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:notionnext-org:notionnext:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Authentication Guard"
          ],
          "product": "NotionNext",
          "vendor": "notionnext-org",
          "versions": [
            {
              "status": "affected",
              "version": "4.10.0"
            },
            {
              "status": "affected",
              "version": "4.10.1"
            },
            {
              "status": "affected",
              "version": "4.10.2"
            },
            {
              "status": "affected",
              "version": "4.10.3"
            },
            {
              "status": "affected",
              "version": "4.10.4"
            },
            {
              "status": "affected",
              "version": "4.10.5"
            },
            {
              "status": "affected",
              "version": "4.10.6"
            },
            {
              "status": "affected",
              "version": "4.10.7"
            },
            {
              "status": "affected",
              "version": "4.10.8"
            },
            {
              "status": "affected",
              "version": "4.10.9"
            },
            {
              "status": "affected",
              "version": "4.10.10"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "zyx122126 (VulDB User)"
        },
        {
          "lang": "en",
          "type": "coordinator",
          "value": "VulDB CNA Team"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in notionnext-org NotionNext up to 4.10.10. Affected by this issue is the function cleanCache of the file pages/api/cache.js of the component Authentication Guard. The manipulation of the argument token leads to missing authentication. The attack may be initiated remotely. Versions 4.1.0 - 4.9.5.2 allow unauthenticated exploitation due to missing method check. In versions 4.9.5.7 - 4.10.10 a guard present but only enforced when CACHE_REVALIDATION_TOKEN is set. Default deployments remain unprotected. The vendor was contacted early about this disclosure but did not respond in any way."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:X/RL:X/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:X/RL:X/RC:C",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P/E:ND/RL:ND/RC:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "Missing Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-28T05:45:11.793Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-410874 | notionnext-org NotionNext Authentication Guard cache.js cleanCache missing authentication",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/410874"
        },
        {
          "name": "VDB-410874 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/410874/cti"
        },
        {
          "name": "CVE-2026-101004 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-101004"
        },
        {
          "name": "Submit #920379 | notionnext-org NotionNext main branch Missing Authentication for Critical Function (CWE-306)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/920379"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-09-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-09-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-09-27T12:43:01.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "notionnext-org NotionNext Authentication Guard cache.js cleanCache missing authentication",
      "x_generator": [
        "VulDB PVTS v202609"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-101004",
    "datePublished": "2026-09-28T05:45:11.793Z",
    "dateReserved": "2026-09-27T10:37:57.027Z",
    "dateUpdated": "2026-09-28T12:27:03.397Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}