Refine your search
153 vulnerabilities found for JT2Go by Siemens
CVE-2024-41902 (GCVE-0-2024-41902)
Vulnerability from cvelistv5
Published
2024-10-08 08:40
Modified
2024-10-08 18:03
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been identified in JT2Go (All versions < V2406.0003). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41902",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-08T18:02:30.732549Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T18:03:27.584Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2406.0003). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:40:18.170Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-626178.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41902",
"datePublished": "2024-10-08T08:40:18.170Z",
"dateReserved": "2024-07-23T10:56:51.267Z",
"dateUpdated": "2024-10-08T18:03:27.584Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-7066 (GCVE-0-2023-7066)
Vulnerability from cvelistv5
Published
2024-08-12 21:46
Modified
2025-08-27 20:42
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
Summary
The affected applications contain an out of bounds read past the end of
an allocated structure while parsing specially crafted PDF files. This
could allow an attacker to execute code in the context of the current
process.
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: 0 < V14.3.0.8 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-7066",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-14T13:56:38.749766Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:53.230Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.1.0.14",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "V14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "V14.3.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "V2312.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "MoyunSec reported this vulnerability to Siemens."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected applications contain an out of bounds read past the end of \nan allocated structure while parsing specially crafted PDF files. This \ncould allow an attacker to execute code in the context of the current \nprocess."
}
],
"value": "The affected applications contain an out of bounds read past the end of \nan allocated structure while parsing specially crafted PDF files. This \ncould allow an attacker to execute code in the context of the current \nprocess."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T21:46:38.910Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-722010.html"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\nSiemens has released new versions for the affected products and recommends to update to the latest versions.\n\n:\u003c/p\u003e\u003cul\u003e\u003cli\u003eTeamcenter Visualization V14.1: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.1.0.14 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.2: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.2.0.10 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eJT2Go: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://plm.sw.siemens.com/en-US/plmcomponents/jt/jt2go/\"\u003eV14.3.0.8 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V14.3: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV14.3.0.8 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization V2312: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eV2312.0002 or later version\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\nFor more information see the associated Siemens security advisory SSA-722010\n\n\n\n\u003cbr\u003e"
}
],
"value": "Siemens has released new versions for the affected products and recommends to update to the latest versions.\n\n:\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.14 or later version https://support.sw.siemens.com/ \n * Teamcenter Visualization V14.2: Update to V14.2.0.10 or later version https://support.sw.siemens.com/ \n * JT2Go: Update to V14.3.0.8 or later version https://plm.sw.siemens.com/en-US/plmcomponents/jt/jt2go/ \n * Teamcenter Visualization V14.3: Update to V14.3.0.8 or later version https://support.sw.siemens.com/ \n * Teamcenter Visualization V2312: Update to V2312.0002 or later version https://support.sw.siemens.com/ \n\n\n\nFor more information see the associated Siemens security advisory SSA-722010"
}
],
"source": {
"advisory": "ICSA-24-193-03",
"discovery": "EXTERNAL"
},
"title": "Siemens Teamcenter Visualization and JT2Go Out-of-bounds Read",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo reduce risk, Siemens \nrecommends users not open untrusted PDF files in affected applications.\u003cbr\u003e\u003c/p\u003e\u003cul\u003e\n\u003c/ul\u003e\n\u003cp\u003eAs a general security measure, Siemens recommends protecting network \naccess to devices with appropriate mechanisms. To operate the devices in\n a protected IT environment, Siemens recommends configuring the \nenvironment according to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eSiemens\u0027 operational guidelines for industrial security\u003c/a\u003e and following recommendations in the product manuals.\u003c/p\u003e\n\u003cp\u003eAdditional information on industrial security by Siemens can be found on the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eSiemens industrial security webpage\u003c/a\u003e\u003c/p\u003eFor more information see the associated Siemens security advisory SSA-722010\n\n\u003cbr\u003e"
}
],
"value": "To reduce risk, Siemens \nrecommends users not open untrusted PDF files in affected applications.\n\n\n\n\n\n\nAs a general security measure, Siemens recommends protecting network \naccess to devices with appropriate mechanisms. To operate the devices in\n a protected IT environment, Siemens recommends configuring the \nenvironment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security and following recommendations in the product manuals.\n\n\nAdditional information on industrial security by Siemens can be found on the Siemens industrial security webpage https://www.siemens.com/industrialsecurity \n\nFor more information see the associated Siemens security advisory SSA-722010"
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-7066",
"datePublished": "2024-08-12T21:46:38.910Z",
"dateReserved": "2023-12-21T19:40:53.933Z",
"dateUpdated": "2025-08-27T20:42:53.230Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37997 (GCVE-0-2024-37997)
Vulnerability from cvelistv5
Published
2024-07-09 12:05
Modified
2025-08-27 20:42
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT Open |
Version: 0 < V11.5 |
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt_open:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt_open",
"vendor": "siemens",
"versions": [
{
"lessThan": "V11.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:plm_xml_sdk:v7.1.0.0014:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "plm_xml_sdk",
"vendor": "siemens",
"versions": [
{
"status": "affected",
"version": "V7.1.0.014"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37997",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T13:19:33.793225Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:54.635Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:04:24.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT Open",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PLM XML SDK",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.0.014",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions \u003c V11.5), JT2Go (All versions \u003c V2406.0003), PLM XML SDK (All versions \u003c V7.1.0.014), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.13), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.11), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:40:15.076Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-959281.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-37997",
"datePublished": "2024-07-09T12:05:06.114Z",
"dateReserved": "2024-06-11T08:32:52.184Z",
"dateUpdated": "2025-08-27T20:42:54.635Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37996 (GCVE-0-2024-37996)
Vulnerability from cvelistv5
Published
2024-07-09 12:05
Modified
2025-08-27 20:42
Severity ?
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L
4.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
4.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-476 - NULL Pointer Dereference
Summary
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XML files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT Open |
Version: 0 < V11.5 |
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37996",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-15T18:31:15.685735Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:54.503Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:04:24.762Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT Open",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PLM XML SDK",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.0.014",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0008",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions \u003c V11.5), JT2Go (All versions \u003c V2406.0003), PLM XML SDK (All versions \u003c V7.1.0.014), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.13), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.11), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0003). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XML files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:40:13.781Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-959281.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-37996",
"datePublished": "2024-07-09T12:05:04.781Z",
"dateReserved": "2024-06-11T08:32:52.184Z",
"dateUpdated": "2025-08-27T20:42:54.503Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-34086 (GCVE-0-2024-34086)
Vulnerability from cvelistv5
Published
2024-05-14 10:03
Modified
2024-08-02 02:42
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-787 - Out-of-bounds Write
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file.
This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: 0 < V2312.0001 |
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "V14.1.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.3.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-34086",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T15:19:05.198442Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T18:22:25.821Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:42:59.863Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.1.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file.\r\nThis could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:55.854Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-34086",
"datePublished": "2024-05-14T10:03:10.774Z",
"dateReserved": "2024-04-30T09:05:07.900Z",
"dateUpdated": "2024-08-02T02:42:59.863Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-34085 (GCVE-0-2024-34085)
Vulnerability from cvelistv5
Published
2024-05-14 10:03
Modified
2024-08-02 02:42
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: 0 < V2312.0001 |
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.1.0.13",
"status": "affected",
"version": "14.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "14.2.0.10",
"status": "affected",
"version": "14.2",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "2312.0001",
"status": "affected",
"version": "2312",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-34085",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T14:07:42.511828Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T18:03:43.492Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:42:59.891Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.1.0.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0001), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.13), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.10), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.7), Teamcenter Visualization V2312 (All versions \u003c V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:54.668Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-661579.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-34085",
"datePublished": "2024-05-14T10:03:09.574Z",
"dateReserved": "2024-04-30T09:05:07.900Z",
"dateUpdated": "2024-08-02T02:42:59.891Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32637 (GCVE-0-2024-32637)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-13 07:54
Severity ?
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L
4.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
4.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-476 - NULL Pointer Dereference
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: 0 < V2312.0005 |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ps_iges_parasolid_translator_component",
"vendor": "siemens",
"versions": [
{
"lessThan": "v27.1.215 ",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32637",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:33.414539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-18T18:07:35.849Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.086Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:07.678Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32637",
"datePublished": "2024-05-14T10:02:44.682Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:07.678Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32636 (GCVE-0-2024-32636)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-13 07:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-125 - Out-of-bounds Read
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: 0 < V2312.0005 |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.208",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.173",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32636",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:41.622204Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:29:19.950Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.376Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:06.352Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32636",
"datePublished": "2024-05-14T10:02:43.480Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:06.352Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32635 (GCVE-0-2024-32635)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-13 07:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-125 - Out-of-bounds Read
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: 0 < V2312.0005 |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.256",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.208",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.173",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32635",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:37:49.970409Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:27:51.096Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:13:40.417Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:05.071Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32635",
"datePublished": "2024-05-14T10:02:42.291Z",
"dateReserved": "2024-04-16T10:52:15.707Z",
"dateUpdated": "2024-08-13T07:54:05.071Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26277 (GCVE-0-2024-26277)
Vulnerability from cvelistv5
Published
2024-04-09 08:34
Modified
2024-08-13 07:54
Severity ?
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L
4.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
4.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-476 - NULL Pointer Dereference
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: 0 < V2312.0004 |
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26277",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-09T19:51:56.120704Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:49:18.998Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:18.954Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:03.735Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26277",
"datePublished": "2024-04-09T08:34:38.896Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:03.735Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26276 (GCVE-0-2024-26276)
Vulnerability from cvelistv5
Published
2024-04-09 08:34
Modified
2024-08-13 07:54
Severity ?
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L
4.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
4.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: 0 < V2312.0004 |
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.254",
"status": "affected",
"version": "35.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.0.207",
"status": "affected",
"version": "36.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "36.1.147",
"status": "affected",
"version": "36.1",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26276",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:40:25.505191Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T14:53:58.636Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:18.871Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:02.376Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26276",
"datePublished": "2024-04-09T08:34:37.744Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:02.376Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-26275 (GCVE-0-2024-26275)
Vulnerability from cvelistv5
Published
2024-04-09 08:34
Modified
2024-08-13 07:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-125 - Out-of-bounds Read
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: 0 < V2312.0004 |
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "jt2go",
"vendor": "siemens",
"versions": [
{
"lessThan": "2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:teamcenter_visualization:14.2:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:teamcenter_visualization:14.3:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:teamcenter_visualization:2312:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "teamcenter_visualization",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "14.2",
"versionType": "custom"
},
{
"lessThan": "14.3.0.9",
"status": "affected",
"version": "14.3",
"versionType": "custom"
},
{
"lessThan": "2312.0004",
"status": "affected",
"version": "2312",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-26275",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-09T15:24:40.222186Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T18:33:02.344Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:07:19.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V35.1.254",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.0.207",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V36.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.1.147",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.2.0.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V14.3.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0004",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0004), Parasolid V35.1 (All versions \u003c V35.1.254), Parasolid V36.0 (All versions \u003c V36.0.207), Parasolid V36.1 (All versions \u003c V36.1.147), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.9), Teamcenter Visualization V2312 (All versions \u003c V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-13T07:54:00.911Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-26275",
"datePublished": "2024-04-09T08:34:36.604Z",
"dateReserved": "2024-02-15T10:54:03.168Z",
"dateUpdated": "2024-08-13T07:54:00.911Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51746 (GCVE-0-2023-51746)
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2024-09-04 15:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.3.0.6 |
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:48:11.101Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51746",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-04T15:13:57.367529Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-04T15:14:05.889Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:18.333Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-51746",
"datePublished": "2024-01-09T10:00:18.333Z",
"dateReserved": "2023-12-22T11:30:22.672Z",
"dateUpdated": "2024-09-04T15:14:05.889Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51745 (GCVE-0-2023-51745)
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2025-06-03 14:31
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.3.0.6 |
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:40:34.255Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51745",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T18:45:55.954048Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-03T14:31:19.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:17.032Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-51745",
"datePublished": "2024-01-09T10:00:17.032Z",
"dateReserved": "2023-12-22T11:30:22.671Z",
"dateUpdated": "2025-06-03T14:31:19.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51744 (GCVE-0-2023-51744)
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2025-06-09 20:32
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-476 - NULL Pointer Dereference
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.3.0.6 |
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:40:34.169Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51744",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T20:30:16.453695Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T20:32:57.525Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476: NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:15.708Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-51744",
"datePublished": "2024-01-09T10:00:15.708Z",
"dateReserved": "2023-12-22T11:30:22.671Z",
"dateUpdated": "2025-06-09T20:32:57.525Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-51439 (GCVE-0-2023-51439)
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2025-04-17 17:54
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-125 - Out-of-bounds Read
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.3.0.6 |
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:32:10.018Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-51439",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-10T18:29:28.656739Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-17T17:54:26.450Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.9"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.6), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.13), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.12), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.9), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.6). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T10:00:14.394Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-794653.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-51439",
"datePublished": "2024-01-09T10:00:14.394Z",
"dateReserved": "2023-12-19T11:47:14.991Z",
"dateUpdated": "2025-04-17T17:54:26.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-38405 (GCVE-0-2021-38405)
Vulnerability from cvelistv5
Published
2023-11-21 18:19
Modified
2024-08-04 01:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
The Datalogics APDFL library used in affected products is vulnerable to memory corruption condition while parsing specially crafted PDF files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: 0 < 13.2.0.7 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:37:16.588Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-041-07"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "13.2.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"lessThan": "12.4.0.13",
"status": "affected",
"version": "12.4",
"versionType": "custom"
},
{
"lessThan": "13.1.0.8",
"status": "affected",
"version": "13.1",
"versionType": "custom"
},
{
"lessThan": "13.2.0.7",
"status": "affected",
"version": "13.2",
"versionType": "custom"
},
{
"lessThan": "13.3.0.1",
"status": "affected",
"version": "13.3",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Mat Powell of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to Siemens and CISA."
}
],
"datePublic": "2022-06-16T16:46:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Datalogics APDFL library used in affected products is vulnerable to memory corruption condition\u0026nbsp;while parsing specially crafted PDF files. An attacker could leverage this vulnerability to execute code\u0026nbsp;in the context of the current process."
}
],
"value": "The Datalogics APDFL library used in affected products is vulnerable to memory corruption condition\u00a0while parsing specially crafted PDF files. An attacker could leverage this vulnerability to execute code\u00a0in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-21T18:19:10.557Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-041-07"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003eSiemens has released updates for some of the affected products and \nrecommends updating to the latest versions. Siemens is preparing further\n updates and recommends specific countermeasures for products where \nupdates are not yet available.\u003c/p\u003e\n\u003cul\u003e\u003cli\u003eJT2Go: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\"\u003eUpdate to v13.2.0.7\u003c/a\u003e\u0026nbsp;or later version\u003c/li\u003e\u003cli\u003eTeamcenter Visualization v13.1: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to v13.1.0.9 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003eTeamcenter Visualization v13.2: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to v13.2.0.7 or later version\u003c/a\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization v13.3: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to v13.3.0.1 or later version\u003c/a\u003e\u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ePlease see Siemens security advisory \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\"\u003eSSA-301589\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: var(--wht);\"\u003efor more information.\u003c/span\u003e\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Siemens has released updates for some of the affected products and \nrecommends updating to the latest versions. Siemens is preparing further\n updates and recommends specific countermeasures for products where \nupdates are not yet available.\n\n\n * JT2Go: Update to v13.2.0.7 https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html \u00a0or later version\n * Teamcenter Visualization v13.1: Update to v13.1.0.9 or later version https://support.sw.siemens.com/ \n * Teamcenter Visualization v13.2: Update to v13.2.0.7 or later version https://support.sw.siemens.com/ \n * Teamcenter Visualization v13.3: Update to v13.3.0.1 or later version https://support.sw.siemens.com/ \n\n\n\nPlease see Siemens security advisory SSA-301589 https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf \u00a0for more information."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Siemens Solid Edge, JT2Go, and Teamcenter Visualization Improper Restriction of Operations within the Bounds of a Memory Buffer",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003eSiemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:\u003c/p\u003e\n\u003cul\u003e\u003cli\u003eAvoid opening untrusted files from unknown sources in affected products.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eAs a general security measure, Siemens strongly recommends \nprotecting network access to devices with appropriate mechanisms. In \norder to operate the devices in a protected IT environment, Siemens \nrecommends configuring the environment according to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf\"\u003eSiemens\u2019 operational guidelines for industrial security\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e, and to follow the recommendations in the product manuals.\u003c/span\u003e\u003c/p\u003e\n\u003cp\u003eAdditional information on industrial security by Siemens can be found on the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eSiemens industrial security webpage\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003c/span\u003e\u003c/p\u003e\n\u003cp\u003ePlease see Siemens security advisory \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf\"\u003eSSA-301589\u003c/a\u003e\u0026nbsp;\u003cspan style=\"background-color: var(--wht);\"\u003efor more information.\u003c/span\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:\n\n\n * Avoid opening untrusted files from unknown sources in affected products.\n\n\n\nAs a general security measure, Siemens strongly recommends \nprotecting network access to devices with appropriate mechanisms. In \norder to operate the devices in a protected IT environment, Siemens \nrecommends configuring the environment according to Siemens\u2019 operational guidelines for industrial security https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf , and to follow the recommendations in the product manuals.\n\n\nAdditional information on industrial security by Siemens can be found on the Siemens industrial security webpage https://www.siemens.com/industrialsecurity .\n\n\nPlease see Siemens security advisory SSA-301589 https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf \u00a0for more information."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-38405",
"datePublished": "2023-11-21T18:19:10.557Z",
"dateReserved": "2021-08-10T19:21:41.085Z",
"dateUpdated": "2024-08-04T01:37:16.588Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38076 (GCVE-0-2023-38076)
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.3.0.1 |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.747Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:28.851Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38076",
"datePublished": "2023-09-12T09:32:20.160Z",
"dateReserved": "2023-07-12T13:18:53.823Z",
"dateUpdated": "2024-08-02T17:30:13.747Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38075 (GCVE-0-2023-38075)
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-416 - Use After Free
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.3.0.1 |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.592Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416: Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:27.558Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38075",
"datePublished": "2023-09-12T09:32:19.039Z",
"dateReserved": "2023-07-12T13:18:53.823Z",
"dateUpdated": "2024-08-02T17:30:13.592Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38074 (GCVE-0-2023-38074)
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20840)
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.3.0.1 |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.057Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20840)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:26.239Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38074",
"datePublished": "2023-09-12T09:32:17.948Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:14.057Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38073 (GCVE-0-2023-38073)
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20826)
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.3.0.1 |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.105Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20826)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:24.893Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38073",
"datePublished": "2023-09-12T09:32:16.855Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:14.105Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38072 (GCVE-0-2023-38072)
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-787 - Out-of-bounds Write
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20825)
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.3.0.1 |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.939Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20825)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:23.586Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38072",
"datePublished": "2023-09-12T09:32:15.739Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:13.939Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38071 (GCVE-0-2023-38071)
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-11-25 21:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824)
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.3.0.1 |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:13.596Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38071",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-25T21:17:44.338467Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T21:17:56.790Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:22.297Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38071",
"datePublished": "2023-09-12T09:32:14.673Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-11-25T21:17:56.790Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38070 (GCVE-0-2023-38070)
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-08-02 17:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818)
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.3.0.1 |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:30:14.028Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.3.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0010"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0004"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.3.0.1), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.6), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0010), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-14T11:03:21.001Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38070",
"datePublished": "2023-09-12T09:32:13.603Z",
"dateReserved": "2023-07-12T13:18:53.822Z",
"dateUpdated": "2024-08-02T17:30:14.028Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38683 (GCVE-0-2023-38683)
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-10-11 13:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-787 - Out-of-bounds Write
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Teamcenter Visualization V13.2 (All versions < V13.2.0.14), Teamcenter Visualization V14.1 (All versions < V14.1.0.10), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted TIFF file. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.2.0.5 |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:46:56.939Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38683",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T13:15:58.316782Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T13:16:08.622Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.14"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.5), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.14), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.10), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.5). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted TIFF file. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-08T09:20:48.395Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38683",
"datePublished": "2023-08-08T09:20:48.395Z",
"dateReserved": "2023-07-24T13:55:32.997Z",
"dateUpdated": "2024-10-11T13:16:08.622Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38682 (GCVE-0-2023-38682)
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-10-11 13:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-125 - Out-of-bounds Read
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Teamcenter Visualization V13.2 (All versions < V13.2.0.14), Teamcenter Visualization V14.1 (All versions < V14.1.0.10), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted TIFF files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.2.0.5 |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:46:56.643Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38682",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T13:17:15.547740Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T13:17:25.296Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.14"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.5), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.14), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.10), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted TIFF files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-08T09:20:47.299Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-38682",
"datePublished": "2023-08-08T09:20:47.299Z",
"dateReserved": "2023-07-24T13:55:32.996Z",
"dateUpdated": "2024-10-11T13:17:25.296Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28830 (GCVE-0-2023-28830)
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-10-23 19:49
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-416 - Use After Free
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Solid Edge SE2022 (All versions < V222.0 Update 13), Solid Edge SE2023 (All versions < V223.0 Update 4), Teamcenter Visualization V13.2 (All versions < V13.2.0.15), Teamcenter Visualization V13.3 (All versions < V13.3.0.11), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted ASM file. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.2.0.5 |
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T13:51:38.123Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28830",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T19:48:40.205775Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T19:49:54.534Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0 Update 13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V223.0 Update 4"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.11"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.5), Solid Edge SE2022 (All versions \u003c V222.0 Update 13), Solid Edge SE2023 (All versions \u003c V223.0 Update 4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.15), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.11), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.11), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.5). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted ASM file. An attacker could leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416: Use After Free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-08T09:20:17.760Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-131450.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-28830",
"datePublished": "2023-08-08T09:20:17.760Z",
"dateReserved": "2023-03-24T15:17:33.934Z",
"dateUpdated": "2024-10-23T19:49:54.534Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-33124 (GCVE-0-2023-33124)
Vulnerability from cvelistv5
Published
2023-06-13 08:17
Modified
2025-01-03 01:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain a memory corruption vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.2.0.3 |
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:35.997Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-33124",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:36:55.445166Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:37:31.531Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.3), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.13), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.10), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.6), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.8), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.3). The affected applications contain a memory corruption vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:17.687Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-33124",
"datePublished": "2023-06-13T08:17:17.687Z",
"dateReserved": "2023-05-17T13:17:47.573Z",
"dateUpdated": "2025-01-03T01:37:31.531Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-33123 (GCVE-0-2023-33123)
Vulnerability from cvelistv5
Published
2023-06-13 08:17
Modified
2025-01-03 01:38
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-125 - Out-of-bounds Read
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.2.0.3 |
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:35.988Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-33123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:37:56.343806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:38:42.204Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.3), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.13), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.10), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.6), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.8), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:16.585Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-33123",
"datePublished": "2023-06-13T08:17:16.585Z",
"dateReserved": "2023-05-17T13:17:47.573Z",
"dateUpdated": "2025-01-03T01:38:42.204Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-33122 (GCVE-0-2023-33122)
Vulnerability from cvelistv5
Published
2023-06-13 08:17
Modified
2025-01-03 01:40
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-125 - Out-of-bounds Read
Summary
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted CGM file. This vulnerability could allow an attacker to disclose sensitive information.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V14.2.0.3 |
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:34.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-33122",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T01:40:14.247239Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T01:40:43.732Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.13"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V13.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.3.0.10"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.0.0.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1.0.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V14.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.2.0.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V14.2.0.3), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.13), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.10), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.6), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.8), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted CGM file. This vulnerability could allow an attacker to disclose sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T08:17:15.483Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-33122",
"datePublished": "2023-06-13T08:17:15.483Z",
"dateReserved": "2023-05-17T13:17:47.573Z",
"dateUpdated": "2025-01-03T01:40:43.732Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}