Refine your search
3 vulnerabilities found for IoTWorX by Mitsubishi Electric Corporation
CVE-2025-7376 (GCVE-0-2025-7376)
Vulnerability from cvelistv5
Published
2025-08-06 06:28
Modified
2026-04-09 05:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-64 - Windows Shortcut Following (.LNK)
Summary
Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS version 11.00, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, and Mitsubishi Electric Iconics Digital Solutions GENESIS version 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7376",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-07T14:11:34.071248Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-07T14:11:44.397Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MobileHMI",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MobileHMI",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Hyper Historian",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Hyper Historian",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AnalytiX",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AnalytiX",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IoTWorX",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "version 10.95"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IoTWorX",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "version 10.95"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "version 11.00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "version 11.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS version 11.00, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, and Mitsubishi Electric Iconics Digital Solutions GENESIS version 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC."
}
],
"value": "Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS version 11.00, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, and Mitsubishi Electric Iconics Digital Solutions GENESIS version 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC."
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "Information Tampering"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-64",
"description": "CWE-64 Windows Shortcut Following (.LNK)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-09T05:10:54.864Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96364629"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-217-01"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Information Tampering Vulnerability in Multiple Processes of GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, AnalytiX, IoTWorX, MC Works64, and GENESIS",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2025-7376",
"datePublished": "2025-08-06T06:28:41.185Z",
"dateReserved": "2025-07-09T02:02:37.759Z",
"dateUpdated": "2026-04-09T05:10:54.864Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-0921 (GCVE-0-2025-0921)
Vulnerability from cvelistv5
Published
2025-05-15 22:36
Modified
2026-04-13 23:06
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-250 - Execution with Unnecessary Privileges
Summary
Execution with Unnecessary Privileges vulnerability in multiple services of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric BizViz all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS versions 11.00, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions, Mitsubishi Electric Iconics Digital Solutions BizViz all versions, and Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the services of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric Corporation | GENESIS64 |
Version: versions 10.97.3 and prior |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0921",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-16T13:21:49.388730Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-16T13:21:55.251Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MobileHMI",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Hyper Historian",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AnalytiX",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IoTWorX",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "version 10.95"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BizViz",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "version 11.00"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MobileHMI",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Hyper Historian",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AnalytiX",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.3 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IoTWorX",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "version 10.95"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS32",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BizViz",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "version 11.00"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Asher Davila from Palo Alto Networks"
},
{
"lang": "en",
"type": "finder",
"value": "Malav Vyas from Palo Alto Networks"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Execution with Unnecessary Privileges vulnerability in multiple services of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric BizViz all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS versions 11.00, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions, Mitsubishi Electric Iconics Digital Solutions BizViz all versions, and Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the services of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC."
}
],
"value": "Execution with Unnecessary Privileges vulnerability in multiple services of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric BizViz all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric GENESIS versions 11.00, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions, Mitsubishi Electric Iconics Digital Solutions BizViz all versions, and Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the services of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC."
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "Information Tampering"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250 Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-13T23:06:00.161Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-002_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU93838985"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-140-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Information Tampering Vulnerability in Multiple Services of GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, AnalytiX, IoTWorX, MC Works64, GENESIS, GENESIS32, and BizViz",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2025-0921",
"datePublished": "2025-05-15T22:36:37.902Z",
"dateReserved": "2025-01-31T01:50:57.976Z",
"dateUpdated": "2026-04-13T23:06:00.161Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-1573 (GCVE-0-2024-1573)
Vulnerability from cvelistv5
Published
2024-07-04 08:59
Modified
2026-04-13 22:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric Iconics Digital Solutions | GENESIS64 |
Version: versions 10.97.2 and prior |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "genesis64",
"vendor": "iconics",
"versions": [
{
"lessThan": "10.97.92",
"status": "affected",
"version": "10.97",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:mitsubishielectric:mc_works64:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mc_works64",
"vendor": "mitsubishielectric",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-1573",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-05T14:46:51.356597Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T14:46:55.563Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:40:21.409Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-004_en.pdf"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU98894016/"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.2 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.2 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.2 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.2 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Hyper Historian",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.2 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Hyper Historian",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.2 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AnalytiX",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.2 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AnalytiX",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.2 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MobileHMI",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "versions 10.97.2 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MobileHMI",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions 10.97.2 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IoTWorX",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "version 10.95"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IoTWorX",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "version 10.95"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) \"Automatic log in\" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in."
}
],
"value": "Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) \"Automatic log in\" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-13T22:47:17.575Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU98894016/"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-184-03"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2024-1573",
"datePublished": "2024-07-04T08:59:44.079Z",
"dateReserved": "2024-02-16T01:30:41.285Z",
"dateUpdated": "2026-04-13T22:47:17.575Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}