Refine your search

1 vulnerability found for Intelligent Connection Center by Dahua

CVE-2025-31704 (GCVE-0-2025-31704)
Vulnerability from cvelistv5
Published
2026-10-30 10:25
Modified
2026-10-30 15:07
Severity ?
CWE
  • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
Summary
A vulnerability has been found in the Dahua Intelligent Connection Center. A remote attacker could send a specially crafted request to the affected system, allowing the attacker to execute arbitrary commands, resulting in remote code execution.
References
Impacted products
Vendor Product Version
Dahua Intelligent Connection Center Version: V1.000.0000000.1   <
Version: V5.000.0000000.6   < V5.000.0000000.15
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31704",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-30T14:56:03.867102Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-30T15:07:34.049Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intelligent Connection Center",
          "vendor": "Dahua",
          "versions": [
            {
              "lessThanOrEqual": "1.000.0000005.0",
              "status": "affected",
              "version": "V1.000.0000000.1",
              "versionType": "custom"
            },
            {
              "lessThan": "V5.000.0000000.15",
              "status": "affected",
              "version": "V5.000.0000000.6",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2026-10-30T08:46:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability has been found in the Dahua Intelligent Connection Center. A remote attacker could send a specially crafted request to the affected system, allowing the attacker to execute arbitrary commands, resulting in remote code execution."
            }
          ],
          "value": "A vulnerability has been found in the Dahua Intelligent Connection Center. A remote attacker could send a specially crafted request to the affected system, allowing the attacker to execute arbitrary commands, resulting in remote code execution."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-116",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-116 Excavation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-30T10:25:46.561Z",
        "orgId": "79ee569e-7d1e-4364-98f0-3a18e2a739ad",
        "shortName": "dahua"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.cnvd.org.cn/flaw/show/CNVD-2025-00420"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Dahua Intelligent Connection Center command injection",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "79ee569e-7d1e-4364-98f0-3a18e2a739ad",
    "assignerShortName": "dahua",
    "cveId": "CVE-2025-31704",
    "datePublished": "2026-10-30T10:25:46.561Z",
    "dateReserved": "2025-04-01T05:57:11.783Z",
    "dateUpdated": "2026-10-30T15:07:34.049Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}