Refine your search

1 vulnerability found for InstallShield by Flexera

CVE-2026-4869 (GCVE-0-2026-4869)
Vulnerability from cvelistv5
Published
2026-10-13 14:10
Modified
2026-10-13 15:49
CWE
Summary
A potential privilege escalation issue was identified in InstallShield version 2025 R2 and earlier when running compressed Basic MSI setup with Prerequisites from an insecure location. If a local administrator launches a compressed Setup.exe with Prerequisites from an unsecured location, the Prerequisite installers also might load from an unsecured location, potentially leading to privilege escalation.
Impacted products
Vendor Product Version
Flexera InstallShield Version: 0   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-4869",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-13T14:52:25.727869Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-13T15:49:47.206Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "InstallShield",
          "vendor": "Flexera",
          "versions": [
            {
              "lessThanOrEqual": "2025 R2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Sandeep Kumar Singh, AMD"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential privilege escalation issue was identified in InstallShield version 2025 R2 and earlier when running compressed Basic MSI setup with Prerequisites from an insecure location. If a local administrator launches a compressed Setup.exe with Prerequisites from an unsecured location, the Prerequisite installers also might load from an unsecured location, potentially leading to privilege escalation."
            }
          ],
          "value": "A potential privilege escalation issue was identified in InstallShield version 2025 R2 and earlier when running compressed Basic MSI setup with Prerequisites from an insecure location. If a local administrator launches a compressed Setup.exe with Prerequisites from an unsecured location, the Prerequisite installers also might load from an unsecured location, potentially leading to privilege escalation."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-38",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-38 Leveraging/Manipulating Configuration File Search Paths"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "LOCAL",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-426",
              "description": "CWE-426 Untrusted Search Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T14:10:11.962Z",
        "orgId": "44d08088-2bea-4760-83a6-1e9be26b15ab",
        "shortName": "flexera"
      },
      "references": [
        {
          "url": "https://community.revenera.com/s/article/CVE-2026-4869-Potential-Privilege-Escalation-in-InstallShield-2025-R2-running-Setup-Prerequisites-from-an-insecure-directory"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Potential Privilege Escalation in InstallShield",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "44d08088-2bea-4760-83a6-1e9be26b15ab",
    "assignerShortName": "flexera",
    "cveId": "CVE-2026-4869",
    "datePublished": "2026-10-13T14:10:11.962Z",
    "dateReserved": "2026-03-25T20:37:08.484Z",
    "dateUpdated": "2026-10-13T15:49:47.206Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}