Refine your search

2 vulnerabilities found for Industrial Edge App Publisher by Siemens

CVE-2026-78557 (GCVE-0-2026-78557)
Vulnerability from cvelistv5
Published
2026-10-13 09:18
Modified
2026-10-13 12:58
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A vulnerability has been identified in Industrial Edge App Publisher (All versions < V1.27.9). The application fails to properly sanitize or escape data received from the backend before rendering it in the user interface. Because the front end is integrated with Node.js, this vulnerability allows for the execution of arbitrary JavaScript, which can be leveraged to achieve remote code execution (RCE) on the victim's machine
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-78557",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-13T12:57:51.267293Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-13T12:58:09.448Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Industrial Edge App Publisher",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.27.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Industrial Edge App Publisher (All versions \u003c V1.27.9). The application fails to properly sanitize or escape data received from the backend before rendering it in the user interface. Because the front end is integrated with Node.js, this vulnerability allows for the execution of arbitrary JavaScript, which can be leveraged to achieve remote code execution (RCE) on the victim\u0027s machine"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:18:56.393Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-968435.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-78557",
    "datePublished": "2026-10-13T09:18:56.393Z",
    "dateReserved": "2026-08-24T19:48:32.550Z",
    "dateUpdated": "2026-10-13T12:58:09.448Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-78556 (GCVE-0-2026-78556)
Vulnerability from cvelistv5
Published
2026-10-13 09:18
Modified
2026-10-16 17:18
CWE
  • CWE-295 - Improper Certificate Validation
Summary
A vulnerability has been identified in Industrial Edge App Publisher (All versions < V1.27.9). The affected software does not properly validate the server certificate when initiating a TLS connection. This allows an attacker to intercept and relay communication (Man-in-the-Middle attack) and to spoof a trusted entity by interfering in the communication path between the client and the intended server.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-78556",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-16T17:00:04.818691Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-16T17:18:08.808Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Industrial Edge App Publisher",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.27.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Industrial Edge App Publisher (All versions \u003c V1.27.9). The affected software does not properly validate the server certificate when initiating a TLS connection. This allows an attacker to intercept and relay communication (Man-in-the-Middle attack) and to spoof a trusted entity by interfering in the communication path between the client and the intended server."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.6,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-295",
              "description": "CWE-295: Improper Certificate Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-13T09:18:55.291Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-968435.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2026-78556",
    "datePublished": "2026-10-13T09:18:55.291Z",
    "dateReserved": "2026-08-24T19:48:32.550Z",
    "dateUpdated": "2026-10-16T17:18:08.808Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}