9 vulnerabilities found for ICR890-4 by SICK AG
CVE-2026-11841 (GCVE-0-2026-11841)
Vulnerability from cvelistv5
Published
2026-07-28 09:25
Modified
2026-08-24 13:54
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-552 - Files or directories accessible to external parties
Summary
An attacker may perform unauthenticated read and write operations on sensitive filesystem areas via the AppEngine Fileaccess over HTTP due to improper access restrictions. A critical filesystem directory was unintentionally exposed through the HTTP-based file access feature, allowing access without authentication. This includes device parameter files, enabling an attacker to read and modify application settings, including customer-defined passwords. Additionally, exposure of the custom application directory may allow execution of arbitrary Lua code within the sandboxed AppEngine environment.
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SICK AG | InspectorP61x |
Version: 0 < 5.4.0 |
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11841",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-28T19:13:27.519553Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-28T19:15:14.851Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "InspectorP61x",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "5.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "InspectorP62x",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "5.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "InspectorP65x",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "affected",
"product": "InspectorP63x",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "affected",
"product": "InspectorP64x",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "affected",
"product": "ICR890-4",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "2.15.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2026-07-28T10:47:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn attacker may perform unauthenticated read and write operations on sensitive filesystem areas via the AppEngine Fileaccess over HTTP due to improper access restrictions. A critical filesystem directory was unintentionally exposed through the HTTP-based file access feature, allowing access without authentication. This includes device parameter files, enabling an attacker to read and modify application settings, including customer-defined passwords. Additionally, exposure of the custom application directory may allow execution of arbitrary Lua code within the sandboxed AppEngine environment.\u003c/p\u003e"
}
],
"value": "An attacker may perform unauthenticated read and write operations on sensitive filesystem areas via the AppEngine Fileaccess over HTTP due to improper access restrictions. A critical filesystem directory was unintentionally exposed through the HTTP-based file access feature, allowing access without authentication. This includes device parameter files, enabling an attacker to read and modify application settings, including customer-defined passwords. Additionally, exposure of the custom application directory may allow execution of arbitrary Lua code within the sandboxed AppEngine environment."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552 Files or directories accessible to external parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-24T13:54:22.224Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"x_SICK PSIRT Security Advisories"
],
"url": "https://www.sick.com/psirt"
},
{
"tags": [
"x_SICK Operating Guidelines"
],
"url": "https://www.sick.com/media/docs/9/19/719/special_information_sick_operating_guidelines_cybersecurity_by_sick_en_im0106719.pdf"
},
{
"tags": [
"x_ICS-CERT recommended practices on Industrial Security"
],
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"tags": [
"x_CVSS v3.1 Calculator"
],
"url": "https://www.first.org/cvss/calculator/3.1"
},
{
"tags": [
"x_The canonical URL."
],
"url": "https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0010.json"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0010.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cspan\u003eFor\u0026nbsp;\u003c/span\u003eInspectorP61x and InspectorP62x: Users are recommended to upgrade to version 5.4.0.\u003c/div\u003e"
}
],
"value": "For\u00a0InspectorP61x and InspectorP62x: Users are recommended to upgrade to version 5.4.0."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "For ICR890-4: Users are recommended to upgrade to version 2.15.0"
}
],
"value": "For ICR890-4: Users are recommended to upgrade to version 2.15.0"
}
],
"source": {
"advisory": "SCA-2026-0010",
"discovery": "INTERNAL"
},
"title": "CVE-2026-11841",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003ePlease make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \u201dSICK Operating Guidelines\u201d and \u201dICS-CERT recommended practices on Industrial Security\u201d could help to implement the general security practices.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \u201dSICK Operating Guidelines\u201d and \u201dICS-CERT recommended practices on Industrial Security\u201d could help to implement the general security practices."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2026-11841",
"datePublished": "2026-07-28T09:25:36.738Z",
"dateReserved": "2026-06-10T06:53:18.277Z",
"dateUpdated": "2026-08-24T13:54:22.224Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-35699 (GCVE-0-2023-35699)
Vulnerability from cvelistv5
Published
2023-07-10 09:39
Modified
2026-06-01 12:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-313 - Cleartext Storage in a File or on Disk
Summary
Cleartext Storage on Disk in the SICK ICR890-4 could allow an unauthenticated attacker with local access to the device to disclose sensitive information by accessing a SD card.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:30:44.141Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-35699",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-25T19:50:31.404610Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-25T19:51:39.248Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "ICR890-4",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cleartext Storage on Disk in the SICK ICR890-4 could allow an unauthenticated attacker with local access to the device to disclose sensitive information by accessing a SD card."
}
],
"value": "Cleartext Storage on Disk in the SICK ICR890-4 could allow an unauthenticated attacker with local access to the device to disclose sensitive information by accessing a SD card."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-313",
"description": "CWE-313 Cleartext Storage in a File or on Disk",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T12:10:16.255Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"source": {
"discovery": "INTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please make sure that you apply general security practices when operating the SICK ICR890-\n4 like restricting physical access to the device. The following general security practices could mitigate\nthe associated security risk.\n\n\n\u003cbr\u003e"
}
],
"value": "Please make sure that you apply general security practices when operating the SICK ICR890-\n4 like restricting physical access to the device. The following general security practices could mitigate\nthe associated security risk."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-35699",
"datePublished": "2023-07-10T09:39:45.804Z",
"dateReserved": "2023-06-15T11:32:19.767Z",
"dateUpdated": "2026-06-01T12:10:16.255Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-35698 (GCVE-0-2023-35698)
Vulnerability from cvelistv5
Published
2023-07-10 09:37
Modified
2026-06-01 12:11
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-204 - Observable Response Discrepancy
Summary
Observable Response Discrepancy in the SICK ICR890-4 could allow a remote attacker to identify valid usernames for the FTP server from the response given during a failed login
attempt.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:30:44.401Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-35698",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-25T19:50:35.574284Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-25T19:51:56.241Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "ICR890-4",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Observable Response Discrepancy in the SICK ICR890-4 could allow a remote attacker to identify valid usernames for the FTP server from the response given during a failed login\nattempt."
}
],
"value": "Observable Response Discrepancy in the SICK ICR890-4 could allow a remote attacker to identify valid usernames for the FTP server from the response given during a failed login\nattempt."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-204",
"description": "CWE-204 Observable Response Discrepancy",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T12:11:21.524Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The recommended solution is to update the firmware to a version \u0026gt;= V2.5.0 as soon as\npossible.\n\n\u003cbr\u003e"
}
],
"value": "The recommended solution is to update the firmware to a version \u003e= V2.5.0 as soon as\npossible."
}
],
"source": {
"discovery": "INTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-35698",
"datePublished": "2023-07-10T09:37:22.798Z",
"dateReserved": "2023-06-15T11:32:19.767Z",
"dateUpdated": "2026-06-01T12:11:21.524Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-35697 (GCVE-0-2023-35697)
Vulnerability from cvelistv5
Published
2023-07-10 09:35
Modified
2026-06-01 12:12
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Summary
Improper Restriction of Excessive Authentication Attempts in the SICK ICR890-4
could allow a remote attacker to brute-force user credentials.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:30:44.508Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:sick_ag:icr890-4:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "icr890-4",
"vendor": "sick_ag",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-35697",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T14:11:42.784362Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T14:12:57.135Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "ICR890-4",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Restriction of Excessive Authentication Attempts in the SICK ICR890-4\ncould allow a remote attacker to brute-force user credentials."
}
],
"value": "Improper Restriction of Excessive Authentication Attempts in the SICK ICR890-4\ncould allow a remote attacker to brute-force user credentials."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T12:12:03.933Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The recommended solution is to update the firmware to a version \u0026gt;= V2.5.0 as soon as\npossible.\n\n\u003cbr\u003e"
}
],
"value": "The recommended solution is to update the firmware to a version \u003e= V2.5.0 as soon as\npossible."
}
],
"source": {
"discovery": "INTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-35697",
"datePublished": "2023-07-10T09:35:52.067Z",
"dateReserved": "2023-06-15T11:32:19.767Z",
"dateUpdated": "2026-06-01T12:12:03.933Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-35696 (GCVE-0-2023-35696)
Vulnerability from cvelistv5
Published
2023-07-10 09:32
Modified
2026-06-01 12:12
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Summary
Unauthenticated endpoints in the SICK ICR890-4 could allow an unauthenticated
remote attacker to retrieve sensitive information about the device via HTTP requests.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:30:44.643Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:sick_ag:icr890-4:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "icr890-4",
"vendor": "sick_ag",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-35696",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T14:38:05.414683Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T14:38:32.412Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "ICR890-4",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Unauthenticated endpoints in the SICK ICR890-4 could allow an unauthenticated\nremote attacker to retrieve sensitive information about the device via HTTP requests."
}
],
"value": "Unauthenticated endpoints in the SICK ICR890-4 could allow an unauthenticated\nremote attacker to retrieve sensitive information about the device via HTTP requests."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T12:12:37.020Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The recommended solution is to update the firmware to a version \u0026gt;= V2.5.0 as soon as\npossible.\n\n\u003cbr\u003e"
}
],
"value": "The recommended solution is to update the firmware to a version \u003e= V2.5.0 as soon as\npossible."
}
],
"source": {
"discovery": "INTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-35696",
"datePublished": "2023-07-10T09:32:57.842Z",
"dateReserved": "2023-06-15T11:32:19.767Z",
"dateUpdated": "2026-06-01T12:12:37.020Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-3273 (GCVE-0-2023-3273)
Vulnerability from cvelistv5
Published
2023-07-10 09:31
Modified
2026-06-01 12:20
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-284 - Improper Access Control
Summary
Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to affect the availability of the device by changing settings of the device such as the IP
address based on missing access control.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:48:08.408Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:sick_ag:icr890-4:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "icr890-4",
"vendor": "sick_ag",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3273",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T14:17:22.856069Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T14:17:56.263Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "ICR890-4",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to affect the availability of the device by changing settings of the device such as the IP\naddress based on missing access control."
}
],
"value": "Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to affect the availability of the device by changing settings of the device such as the IP\naddress based on missing access control."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T12:20:21.236Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"source": {
"discovery": "INTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SICK recommends to disable port 2111 \u0026amp; 2122 once the SICK ICR890-4 is put into operation.\n\n\u003cbr\u003e"
}
],
"value": "SICK recommends to disable port 2111 \u0026 2122 once the SICK ICR890-4 is put into operation."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-3273",
"datePublished": "2023-07-10T09:31:17.829Z",
"dateReserved": "2023-06-15T11:32:34.499Z",
"dateUpdated": "2026-06-01T12:20:21.236Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-3272 (GCVE-0-2023-3272)
Vulnerability from cvelistv5
Published
2023-07-10 09:27
Modified
2026-06-01 12:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Summary
Cleartext Transmission of Sensitive Information in the SICK ICR890-4 could allow a
remote attacker to gather sensitive information by intercepting network traffic that is not encrypted.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:48:08.392Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:sick_ag:icr890-4:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "icr890-4",
"vendor": "sick_ag",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3272",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T14:18:17.926598Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T14:18:45.915Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "ICR890-4",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cleartext Transmission of Sensitive Information in the SICK ICR890-4 could allow a\nremote attacker to gather sensitive information by intercepting network traffic that is not encrypted."
}
],
"value": "Cleartext Transmission of Sensitive Information in the SICK ICR890-4 could allow a\nremote attacker to gather sensitive information by intercepting network traffic that is not encrypted."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T12:18:35.427Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"source": {
"discovery": "INTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SICK recommends to disable port 2111 \u0026amp; 2122 once the SICK ICR890-4 is put into operation.\n\n\u003cbr\u003e"
}
],
"value": "SICK recommends to disable port 2111 \u0026 2122 once the SICK ICR890-4 is put into operation."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-3272",
"datePublished": "2023-07-10T09:27:46.002Z",
"dateReserved": "2023-06-15T11:32:32.808Z",
"dateUpdated": "2026-06-01T12:18:35.427Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-3271 (GCVE-0-2023-3271)
Vulnerability from cvelistv5
Published
2023-07-10 09:26
Modified
2026-06-01 12:20
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-284 - Improper Access Control
Summary
Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to gather information about the system and download data via the REST API by accessing
unauthenticated endpoints.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:48:08.371Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:sick_ag:icr890-4:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "icr890-4",
"vendor": "sick_ag",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3271",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T14:19:06.230650Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T14:19:30.590Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "ICR890-4",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to gather information about the system and download data via the REST API by accessing\nunauthenticated endpoints."
}
],
"value": "Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to gather information about the system and download data via the REST API by accessing\nunauthenticated endpoints."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T12:20:55.083Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The recommended solution is to update the firmware to a version \u0026gt;= V2.5.0 as soon as\npossible.\n\n\u003cbr\u003e"
}
],
"value": "The recommended solution is to update the firmware to a version \u003e= V2.5.0 as soon as\npossible."
}
],
"source": {
"discovery": "INTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-3271",
"datePublished": "2023-07-10T09:26:21.041Z",
"dateReserved": "2023-06-15T11:32:31.460Z",
"dateUpdated": "2026-06-01T12:20:55.083Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-3270 (GCVE-0-2023-3270)
Vulnerability from cvelistv5
Published
2023-07-10 09:18
Modified
2026-06-01 12:19
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Exposure of Sensitive Information to an Unauthorized Actor
Summary
Exposure of Sensitive Information to an Unauthorized Actor in the SICK ICR890-4 could allow an unauthenticated remote attacker to retrieve sensitive information about the system.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:48:08.407Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:sick_ag:icr890-4:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "icr890-4",
"vendor": "sick_ag",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3270",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-12T14:19:58.013611Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-12T14:20:22.953Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "ICR890-4",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "2.5.0",
"status": "affected",
"version": "0",
"versionType": "*"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Exposure of Sensitive Information to an Unauthorized Actor in the SICK ICR890-4 could allow an unauthenticated remote attacker to retrieve sensitive information about the system."
}
],
"value": "Exposure of Sensitive Information to an Unauthorized Actor in the SICK ICR890-4 could allow an unauthenticated remote attacker to retrieve sensitive information about the system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T12:19:29.956Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0006.json"
}
],
"source": {
"discovery": "INTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SICK recommends to disable port 2111 \u0026amp; 2122 once the SICK ICR890-4 is put into operation."
}
],
"value": "SICK recommends to disable port 2111 \u0026 2122 once the SICK ICR890-4 is put into operation."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-3270",
"datePublished": "2023-07-10T09:18:28.375Z",
"dateReserved": "2023-06-15T11:32:12.485Z",
"dateUpdated": "2026-06-01T12:19:29.956Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}